My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_FILE 1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
18846
>
3000 – Underground Injection Control Program
>
PR0546051
>
COMPLIANCE INFO_FILE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:26 PM
Creation date
5/19/2021 9:59:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3000 – Underground Injection Control Program
File Section
COMPLIANCE INFO
FileName_PostFix
FILE 1
RECORD_ID
PR0546051
PE
3030
FACILITY_ID
FA0003883
FACILITY_NAME
VICTOR FINE FOODS
STREET_NUMBER
18846
Direction
N
STREET_NAME
STATE ROUTE 99
City
LODI
Zip
95240
APN
01709051
CURRENT_STATUS
02
SITE_LOCATION
18846 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
319
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS <br /> GOLDEN GATE FRESH FOODS,INC. <br /> dba VICTOR FINE FOODS <br /> SAN JOAQUIN COUNTY <br /> EQUALIZATION/EMERGENCY STORAGE BASIN MONITORING <br /> Freeboard shall be measured daily in the EESB. <br /> LCRS Leachate Monitoring <br /> The equalization/emergency storage basin LCRS sump shall be inspected daily <br /> for leachate generation. Upon detection of measurable leachate in a <br /> previously dry LCRS. The Discharger shall immediately sample the leachate and <br /> shall continue to sample the leachate at the following frequencies thereafter. <br /> Leachate samples shall be analyzed for the following: <br /> Report in Sampling <br /> Parameter/Constituent Units of Frequency <br /> Flow Rate gallons/day Daily <br /> Specific Conductance (field) umhos/cm Daily <br /> pH (field) pH units Daily <br /> Total Dissolved Solids mg/1 Monthly <br /> Chloride mg/l Quarterly <br /> Sulfate mg/l Quarterly <br /> General Minerals mg/l Quarterly <br /> LCRS Testing <br /> The LCRS shall be tested annually to demonstrate operation in conformance with <br /> waste discharge requirements. The results of these tests shall be reported to <br /> the Board and shall include comparison with earlier tests made under <br /> comparable conditions. <br /> Synthetic Liner Monitoring <br /> All visible portions of synthetic liners shall be inspected on a weekly basis <br /> and their condition reported monthly to the Board. <br /> Vadose Zone Monitoring <br /> The following detection monitoring program shall be implemented at the <br /> facility to determine compliance with the water quality protection standards. <br /> The monitoring network shall consist of six lysimeters directly underneath the <br /> basin, which shall constitute the "Points of Compliance" with respect to soil- <br /> pore liquid and one lysimeter upgradient of the basin. Samples from all <br /> lysimeters shall be analyzed for the following parameters: <br />
The URL can be used to link to this page
Your browser does not support the video tag.