TERRAX <br />Environmental Engineering and Consulting <br />Task 2: Well Abandonment <br />The soil vapor well head at each well location will be removed. The soil vapor probe shall be <br />destroyed by removing all material within the original borehole (including the well casing, screen, <br />filter pack, and annular seal). Terrax proposes to advance five (5) Hollow Stem Auger borings (6- <br />inch) centered on each probe (B-1, B2, B3, B5 and B-6) to a terminal depth of 15 feet below <br />ground surface (bgs). <br />The 6-inch boring shall be filled with neat cement by use of a tremie pipe or equivalent, proceeding <br />upward from the bottom of the well or boring. Sealing materials shall be placed in one continuous <br />operation <br />Task 3 Waste Removal <br />Soils will be collected for waste profiling (up to 2 samples). Waste soil will be contained in DOT <br />approved 55-gallon drums on-site. Once the waste is profiled the waste will be transported and <br />disposed of under waste manifest by Belshire Environmental Services, Inc. <br />Sampling procedures will conform to the requirements of the California Department of Toxic <br />Substances Control (DISC) and the Environmental Protection Agency (EPA). All soil samples <br />and groundwater samples will be transported off site for analysis by a state certified laboratory. <br />and/or sampling beyond the proposed scope may be required. The entire project will be performed <br />under the responsible charge of a registered professional civil engineer or geologist. <br />4952 Warner Avenue, Suite 242, Huntington Beach California, 92649 Page 4