My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
I
>
IDEAL
>
17830
>
2200 - Hazardous Waste Program
>
PR0544918
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2021 6:41:27 PM
Creation date
6/24/2021 12:45:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0544918
PE
2220
FACILITY_ID
FA0025534
FACILITY_NAME
ALL STAR HEAVY HAUL & TOW
STREET_NUMBER
17830
Direction
S
STREET_NAME
IDEAL
STREET_TYPE
PKWY
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
17830 S IDEAL PKWY
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q U 1 N Environmental Health Department <br /> U ; i y 1 Iii <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ALL STAR HEAVY HAUL&TOW 1 17830 S IDEAL PKWY, MANTECA October 03, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> OBSERVATION: The following containers of hazardous waste were found on-site with no accumulation start date: <br /> Two drip pans containing used oil were observed without a label or accumulation start date. It could not be <br /> determined how long the used oil had been contained in the drip pans. One unlabeled brown plastic drip pan <br /> containing oil was observed in the south east quadrant of the facility yard on the asphalt next to a truck with the <br /> license plate number 4DBY555. One unlabeled black plastic drip pan containing oil was observed against the south <br /> wall of the facility on the ground positioned halfway on asphalt and half way on the dirt area lining the south <br /> perimeter wall. <br /> REGULATION GUIDANCE: <br /> (a)Except as provided in subsections(c)and (d)of this section and section 66262.35, a generator may accumulate <br /> hazardous waste on-site for 90 days or less without a permit or grant of interim status, provided that: <br /> (b)The beginning of the 90 day period specified in subsections(a)and (c)of this section is determined as follows: <br /> (1)if the generator does not generate more than 100 kilograms of hazardous waste or one kilogram of acutely <br /> hazardous waste(listed in section 66261.33(e))or one kilogram of extremely hazardous waste during any calendar <br /> month, the 90 day period begins on the date the generator has accumulated 100 kilograms of hazardous waste or <br /> one kilogram of acutely hazardous waste or one kilogram of extremely hazardous waste; <br /> (2)if the generator generates more than 100 kilograms of hazardous waste or one kilogram of acutely hazardous <br /> waste or one kilogram of extremely hazardous waste during any calendar month,the 90-day period begins on the <br /> first date on which any amount of hazardous waste begins to accumulate during that month. <br /> (d)Notwithstanding subsections(a)and (c)of this section and section 66262.35, a generator of less than 1,000 <br /> kilograms of hazardous waste in any calendar month who accumulates hazardous waste onsite for 180 days or <br /> less, or 270 days or less if the generator transports the generator's own waste, or offers the generator's waste for <br /> transportation, over a distance of 200 miles or more,for offsite treatment, storage, or disposal, is not a storage <br /> facility if all of the following apply: <br /> (1)The quantity of hazardous waste accumulated onsite never exceeds 6,000 kilograms. <br /> (2)The generator complies with the requirements of 40 Code of Federal Regulations section 262.34(d), (e)and (f). <br /> (3)The generator does not hold acutely hazardous waste or extremely hazardous waste in an amount greater than <br /> one kilogram for more than 90 days. <br /> CORRECTIVE ACTION: Immediately dispose of the hazardous waste stored on site greater than 180 days in <br /> compliance with Title 22 California Code of Regulations. Provide a corrective action statement and a copy of the <br /> disposal records to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> FA0025534 PR0544918 SCO01 10/03/2019 <br /> EHD 22-01 Rev.9/16/2020 Page 9 of 11 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.