Laserfiche WebLink
REFER TO PROJECT SPECIFICATIONS <br /> SHEETS A9.10 TO A9.60 <br /> COUNTER FLASHING. PRE-FINISHED METAL CAP H <br /> FLASHING. PRE-FINISHED METAL CAP fr <br /> PRE-FINISHED METAL CAP FLASHING. FLASHING MUST 9 N 01) <br /> o <br /> - - - - - - - - - FLASHING. SEE ELEVS. SELF-ADHERING SHEET OVERLAP FACE OF PARAPET <br /> - - FLASHING. 0/ LAP 6" (MIN.) 4" MIN. <br /> � rn <br /> r- _____ _ _ _ _ _ _ _ - SELF-ADHERING SHEET OVER WEATHER BARRIERS �"� C-3 <br /> ~ <br /> - - - - - - i LIGHTING. RE: EXT. ELEVS. FOR 4x6 SOLID �, <br /> FLASHING. OVER LAP 6 2x6 WOODS STUDS © w <br /> iE7LOCATION & ELEC. DWG'S. 2 BLOCKING AT <br /> (MIN.) OVER WEATHER i 16 O.C. WITH (1) LAYER x rn <br /> ROOF MEMBRANE CONT. UP & „ „ A7.40 LADDER o C X <br /> BARRIERS 5/8 TYPE X GYP. W <br /> - - ° OVER PARAPET WALL TO OPP. CONNECTION <br /> u WALL BOARD EACH SIDE I <br /> i i ii SIDE OF WALL v UD o <br /> ROOF MEMBRANE CONT. UP & 7/8" CEMENT PLASTER 0/ I X Q? <br /> U CD <br /> OVER PARAPET WALL TO OPP. MTL LATH 0/ 2-LAYERS I O <br /> JUNCTION BOX AND i SIDE OF WALL 9 GRADE "D" PAPER. m �, <br /> TRANSFORMER FOR NEON. i o M <br /> RE: ELECTRICAL i BRICK CLADDING. 8.40 � <br /> ROOF MEMBRANE CONT. UP & i RE: EXTERIOR ELEVS.. i SINGLE-PLY ROOF SYSTEM. I c9 <br /> OVER PARAPET WALL TO OPP. i I RE: ROOF PLAN I ~ <br /> SIDE OF WALL WATER RESISTANT BARRIER <br /> 7/8" CEMENT PLASTER 0/ GRADE 'D' I I ° R30 RIGID ROOF INSULATION. I SUPPORT CLIP PLATE - <br /> MTL LATH 0/ 2-LAYERS RE: SPEC SECTION 07 22 00 BENT PL 3/8x3xO-8" <br /> GRADE "D" PAPER. RE: SPEC. i SINGLE-PLY ROOF SYSTEM. — — — " Ail L @ 4'-0" MAX. W/ 1/2" <br /> i RE: ROOF PLAN ii 2X BLOCKING DIA.xO'-3" LAG SCREW <br /> SINGLE-PLY ROOF SYSTEM. (TYP). <br /> RE: ROOF PLAN i R30 RIGID ROOF INSULATION. Store: <br /> i ROOF STRUCT. ING DWGS.WGS. RUNG 3/4" SQUARE 3x1 x1�8" - HSS 1311 E. YOSEMITE AVE. <br /> 2X BLOCKING i ii <br /> R30 RIGID ROOF INSULATION. i <br /> 1/2" EXTERIOR GRADE ° 1/2" EXTERIOR GRADE 2'-23" MANTECA CA 95336 <br /> i PLYWOOD SHEATHING a PLYWOOD SHEATHING <br /> i <br /> ROOF SHEATHING Restaurant #RC529 <br /> � RE: STRUCT. DWGS. <br /> i <br /> ROOF SHEATHING <br /> RE: STRUCT. DWGS. Professional of Record: NAME <br /> PARAPET ® STUCCO PARAPET @ EXTERIOR MASONRY PARAPET @ TOWER ROOF LADDER DETAIL <br /> 1 1/2"= 1'-0" 1 1//2"= 1'-0" 1 1/2"= 1'-0" 4 1 1/2"= 1'-0" FAA <br /> 1/A1.50 21 3/A7.20 31 1/A1.50; A4.3 A7.40 <br /> DESIGN <br /> PRE-FINISHED METAL A r c h i t e c t u r a l <br /> FLASHING W/ SPRING LOCK Solutions Group <br /> COUNTER FLASHING APPLIED HORIZONTAL RIGID GUARD 1 1/2" 0 STD. p <br /> OVER TOP PLATE ♦ ♦ 11 6 RAIL AT 42" ABOVE DECK. HANDRAIL 38 EXECUTIVE PARK, <br /> PRESSURE TREATED 2X 1 I PAINT RAIL AND STRUTS SUITE 310 <br /> PRE-FINISHED METAL CAP A8.40 A8.40 <br /> BLOCKING 8,40 I BLACK. RAILING SHALL NOT ------- - IRVINE, CA 92614 <br /> STEEL TUB FRAME. I I FLASHING. ROTATE WITHIN ITS FITTING 0 CONTACT: JEFF LIEDERMAN <br /> RE: STRUCTURAL. PAINT 1 1 2" STD. POST @ 48" O.C. (949) 430-7051 <br /> MATTE BLACK <br /> SELF-ADHERING SHEET FLASHING. / <br /> �� I I MAX. & 48" FROM CORNER '��' �`, JLIEDERMAN@PMDGINC.COM <br /> ! OVER LAP 6 (MIN.) OVER WEATHER I I PRE-FINISHED METAL <br /> LIGHT GAUGE METAL STUD — — — — — BARRIERS (CENTER BETWEEN STUDS) , <br /> 0 INFILLCAP FLASHING <br /> PRE-FINISHED METAL PANEL, 7/8" CEMENT PLASTER 0/ RE. SPEC. VERIFY 21" SPHERE WILL <br /> NOT PASS PER CODE <br /> MTL LATH 0/ 2-LAYERS I 1" II - <br /> RIBBED. MATCH COPING GRADE "D" PAPER. I 1 -4 24 GA. PREFINISHED MTL (.0 <br /> Li 1" E.F.I.S. ON 5/8" CAP FLASHING I <br /> ROOF MEMBRANE CONT. UPSIMPSON A34 FROM STUD <br /> I ' <br /> O DENS-GLASS OVER 4 METAL OVER PARAPET WALL TO & ' <br /> I TO PLATES WHERE <br /> STUDS © 16" O.C. <br /> OPP. SIDE OF WALL HANDRAILS POST <br /> STEEL TUB FRAME. PRE-FINISHED METAL ------ -----� BLOCKING OCCURS <br /> RE: STRUCTURAL. PAINTi HORIZONTAL EJECTION <br /> MATTE BLACK HORIZONTAL EJECTION SCUPPER BEHIND <br /> SCUPPER I °' 1 DOWNSPOUTFULLY ADHERED TPO "" e R C <br /> SCUPPER FLANGE (SEAMED N NO i I i i - ® Y S. T�0 <br /> X <br /> ---L------ <br /> SQUARE TUBE FLASHING CD AND SOLDERED TO SCUPPER) - ------ --- --- --- --� -- --- -----1 ---- �! TYP. E�ERMPN <br /> BOOT SINGLE-PLY ROOF SYSTEM. I �iN /16 95-54 <br /> RE: ROOF PLAN I 1 ROOF LINE N N� 0-2 <br /> 00 �z I co 021 <br /> SINGLEPLY ROOF SYSTEM. ( PREFINISHED i = -50 2TE _ <br /> PRE-FINISHED METAL SPOUT I i PP�EWP�oA o� <br /> >1 <br /> j RE: ROOF PLAN EXTENSION, PROVIDE I CONDUCTOR HEAD i Tq R \� <br /> r SEALANT I i TF p F 0 P� <br /> i <br /> 2'-0" <br /> IN <br /> PRE-FINISHED METAL STOP TRIM BAND AT �� o ® o Prototype : P4 EXTENDED- HV, SCHEME A <br /> CONDUCTOR HEAD (NOT PRE-FINISHED METAL GUTTER/ DOWNSPOUT, <br /> ON SECONDARY OVERFLOW EMERGENCY OVERFLOW TYP. N.1 i 3/8"x5"X1'-0" Prototype Issue Date: 6.29.2020 <br /> PRE-FAB CLEAR SPAN USED SCUPPERS) SCUPPER I 6"x4" PRE-FINISHED i �! STEEL PLATE <br /> WOOD TRUSSES -_ L L METAL DOWNSPOUT 3 1/2 x14 PSL i Design Bulletin Updates: INCLUDED <br /> 6"x4" PRE-FINISHED METAL BLOCKING W/ i 3/8%12% 0'-8" FACE <br /> SIMPSON A34 TOPi PLATE W/ 5/8"� x2 1/2" Date Issued: Bulletin Number: <br /> ANCHOR. DOWNSPOUT AND BOTTOM TO i EMBED LAGS TO BLOCKING <br /> STUD i NOV. 2018 1 & 2 <br /> RE: STRUCTURAL o <br /> BRICK CLADDING. <br /> BRACING. RE: EXT. ELEVS.. i 1ST BLDG. SUBMITTAL <br /> RE: STRUCTURAL SCUPPER SECTION SCUPPER ELEVATION WATER RESISTANT <br /> PRE-FAB WOOD 1/A1.50 BARRIER GRADE 'D' i <br /> EXT. PLYWOOD <br /> TRUSSES. RE: <br /> SHEATHING <br /> STRUCT. DWGS. i <br /> 2X WD FRAME WALL <br /> i <br /> — _ _ _ _ _ _ _ ♦ REVISIONS: <br /> 1 1 08-07-20 1st. Bldg. Submittal <br /> ROOFTOP EQUIPMENT SCREEN 8.4° ; ROOF HATCH DETAIL <br /> 2 <br /> PROVIDE DOUBLE ELBOW AT 3 <br /> 511/A1.50 ROOF PENETRATIONS TO ` 81 A1.10 & A7.40 4 <br /> ROUTE COOLER FREEZER <br /> PROVIDE SINGLE PLY � � � � i <br /> 5 <br /> LINES (REFRIGERANT, 6 <br /> POWER, CONTROLS, ETC.) MEMBRANE FLASHING AROUND SCUPPER 0/8(2) LAYERS" STUCCO OF GRADE TH 7 <br /> OPENING, SEAL <br /> SEAL OPENING W/APPROPIATE "D" PAPER 8 <br /> WITH SPRAY FOAM ROOFING SEALANT 9 <br /> PRE-FINISHED <br /> SINGLE PLY MET. ROOF SCUPPER <br /> SIZE PVC PER <br /> 7/8" CEMENT PLASTER 0/ KOLPAK COOLER/ <br /> ROOFING <br /> Sheet Title: <br /> MTL LATH 0/ 2-LAYERS <br /> GRADE "D" PAPER. FREEZER RUNS _ RE-FINISHED ROOFTOP CONDENSER UNIT <br /> METAL SPOUT EXTENSION ANCHOR STRAPSFASTENED TO <br /> PROVIDE SEALANT CURB PER MFR. ROOF DETAILS <br /> 2-PIECE REGLET & WEATHERPROOF 18 GA. GALV. STEEL STRAPS <br /> - - i 12" O.C. <br /> COUNTERFLASHING _ff —_101_ = _ i <br /> MEMBRANE / - - i SCUPPER FLANGE TREATED 2X SOLE PLATE <br /> �o SEALANT PERJDate: 08.07.2020 <br /> i i (SEAMED AND FASTENED TO PLYWOOD DECK <br /> MANUFACTURER R30 RIGID ROOF <br /> i i SOLDERED TO SCUPPER) WITH (2) 3/8"X10" LAG SCREWS <br /> SINGLE-PLY ROOF INSULATION i i Project Number: RAC19024.0 <br /> SYSTEM. RE: ROOF PLAN WITH STANDARD WASHERS Co? 12 <br /> O.C. COUNTERBORE SCREW HEAD <br /> o AND WASHER INTO BLOCKING Drawn By: XXX/XXX <br /> R30 RIGID ROOF i i � TPO CURB FLASHING WELDED <br /> INSULATION. i i TO ROOF MEMBRANE PER MFR. <br /> ROOF SHEATHING 3/4" PLYW OD RF. DECK <br /> RE: STRUCT. DWGS. RE: STRUCT. DWG'S. Sheet Number: <br /> INSULATION AND COVER BOARD <br /> 3/4" PLYWOOD DECK <br /> ROOF FLASHING ROOF PENETRATION DETAIL OVERFLOW SCUPPER SECTION ROOFTOP CURB CONDENSER <br /> A8 . 40 N <br /> 3"= 1'-0" 3"= V-0" 1 1/2"= 1'-0" <br /> 91A7.10 101 1 A1.50 A1.50 <br /> CIO <br />