4 During the October 30, 2008, monitoring system certification, the north diesel <br /> tank fill sump, UDC sump 16A/17B, and north diesel tank piping vacuum sensors <br /> failed when tested. Both diesel leak detectors also failed. <br /> -) During the December 22, 2008, monitoring system certification, the diesel <br /> piping sump annular sensor failed when tested. The 87-octane and 91-octane leak <br /> detectors also failed. <br /> HSC 25292.2 Certification of financial responsibility and chief financial officer <br /> letter. <br /> (a) All owners and operators of an underground tank system shall maintain evidence of <br /> financial responsibility for taking corrective action and for compensating third parties <br /> for bodily injury and property damage caused by a release from the underground <br /> tank system, in accordance with regulations adopted by the board pursuant to <br /> Section 25299.3. The regulations shall include a schedule that requires that financial <br /> responsibility requirements are phased-in for all underground storage tank systems <br /> on or before October 26, 1990. <br /> (b) If the owner and the operator are separate persons, either the owner or the operator <br /> shall demonstrate compliance with subdivision (a). <br /> (c) An owner may comply with this article by entering into an agreement with the <br /> operator of the tank requiring the operator to demonstrate compliance with <br /> subdivision (a). However, both the owner and the operator are in violation of <br /> subdivision (a) if evidence of financial responsibility is not established and <br /> maintained in accordance with this article. <br /> 4 Current financial responsibility documents were not on file with the EHD during <br /> the June 23, 2008, October 30, 2008, December 22, 2008, October 27, 2010, and <br /> November 22, 2010, UST inspections. <br /> Title 23, CCR 2632(b) Monitoring program is current and approved by the local <br /> agency. Owners or operators of underground storage tanks subject to this section shall <br /> implement a monitoring program approved by the local agency and specified in the <br /> underground storage tank operating permit. The program shall include interstitial space <br /> monitoring as described in subsection (c) and shall include the items listed in subsection <br /> (d). <br /> -) A current and approved monitoring plan was not found on site during the <br /> October 19, 2009, December 28, 2009, October 27, 2010, and November 22, 2010 <br /> routine UST inspections. <br /> Title 23, CCR 2636(f)(1) Failed to maintain a continuous monitoring system for <br /> underground piping and UDCs that activates an audible and visual alarm or stops <br /> flow of product at the dispenser when it detects a leak. All secondary containment, <br /> including under-dispenser containment, and under-dispenser spill control or containment <br /> systems shall be equipped with a continuous monitoring system that either activates an <br /> audible and visual alarm or stops the flow of product at the dispenser when it detects a <br /> leak. <br /> --) The diesel north fill sump sensor failed when tested on October 27, 2010, and <br /> was not replaced and retested until November 23, 2010. <br /> Title 23, CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3- <br /> gallon per hour leak. Automatic line leak detectors shall be installed on underground <br /> pressurized piping and shall be capable of detecting a 3-gallon per hour leak rate at 10 <br /> psi within 1 hour with a probability of detection of at least 95 percent and a probability of <br /> 17 <br />