My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
116
>
2300 - Underground Storage Tank Program
>
PR0523684
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2023 2:59:02 PM
Creation date
9/10/2021 4:32:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0523684
PE
2351
FACILITY_ID
FA0015977
FACILITY_NAME
Fast Lane Central Valley
STREET_NUMBER
116
STREET_NAME
ROTH
STREET_TYPE
Rd
City
Lathrop
Zip
95330
APN
196-02-020
CURRENT_STATUS
01
SITE_LOCATION
116 Roth Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> false alarm no greater than 5 percent, and shall restrict or shut off the flow of product <br /> through the piping when a leak is detected. <br /> --) The 91-octane leak detector failed when tested during the November 22, 2010, <br /> UST inspection. <br /> Title 23, CCR 2638(a) Annual monitoring system certification and line leak <br /> detector testing. All monitoring equipment used to satisfy the requirements of this <br /> article shall be installed, calibrated, operated and maintained in accordance with <br /> manufacturer's instructions, and certified every 12 months for operability, proper <br /> operating condition, and proper calibration. Written records shall be maintained as <br /> required in section 2712. <br /> 4 Annual monitoring system certification and leak detector testing for the truck <br /> stop side was performed on October 30, 2008, five months late. <br /> 4 Annual monitoring system certification and leak detector testing for the <br /> automobile side was performed on December 22, 2008, seven months late. <br /> 4 Annual testing of the overfill prevention system for both tanks on the truck stop <br /> side of the facility were tested on February 17, 2010, four months late. <br /> 4 Annual testing of the diesel leak detector on the automobile side of the facility <br /> was tested on February 17, 2010, two months late. <br /> 4 Testing of the smart sensors on the truck stop side of the facility was not <br /> completed until December 8, 2010, two months late. <br /> Title 23, CCR 2638(d) Monitoring system certification test report. UST owners and <br /> operators shall submit a completed "Monitoring System Certification" form to the local <br /> agency within 30 days after completion of the inspection. <br /> 4 The October 30, 2008, monitoring system certification test report was submitted <br /> on January 9, 2009, two months late. <br /> Title 23, CCR 2650 Recording and reporting of unauthorized releases. <br /> (a) The requirements of this article apply to all owners or operators of one or more <br /> underground storage tanks storing hazardous substances. <br /> (b) The owner or operator shall record or report any unauthorized release from the <br /> underground storage tank, and any spill or overfill, in accordance with the <br /> appropriate sections of Chapter 6.7 of Division 20 of the Health and Safety Code and <br /> this article. <br /> (c) The owner or operator of an underground storage tank with secondary containment <br /> shall record any unauthorized release described in section 25294 of the Health and <br /> Safety Code in accordance with section 2651. <br /> (d) Owners or operators subject to the requirements of this article shall report all spills <br /> and overfills in accordance with section 2652. <br /> (e) The owner or operator of an underground storage tank shall report to the local <br /> agency any unauthorized release described in sections 25295 and 25295.5 of the <br /> Health and Safety Code, and shall also record and report any of the following <br /> conditions in accordance with section 2652: <br /> (1) Any unauthorized release recorded or reported under subsections (c) or (d) <br /> which the owner or operator is unable to clean up or which is still under <br /> investigation within eight hours of detection; <br /> (2) The discovery by the owner or operator, local agency, or others of released <br /> hazardous substances at the site of the underground storage tanks or in the <br /> surrounding area. This includes the presence of free product or vapors in soils, <br /> basements, sewer and utility lines, and nearby surface or drinking waters; <br /> 18 <br />