leMECHANICAL SYMBOLS LEGEND MECHANICAL KEYED NOTES PACKAGED HVAC EQUIPMENT SCHEDULE J <br /> OT THERMOSTAT SENSIBLE HEATING / <br /> DESIGNATION MFR. TONNAGE SEER MODEL TOTAL AIRFLOW O.A. TOTAL TOTAL COOLING COOLING CAPACITY SUPPLY FAN MCA MOCP ELECTRIC WEIGHT <br /> O 24„HR, 7 DAY PROGRAMMABLE THERMOSTAT TO BE INSTALLED (CFM) AIRFLOW CAPACITY CAPACITY TYPE <br /> / BHP SERVICE <br /> 48 ABOVE THE FLOOR. <br /> OS TEMPERATURE SENSOR 72 MBH <br /> O2 FURNISH AND INSTALL ROOFTOP UNIT (RTU-1,2) ON ROOF. RTU-1,2 CARRIER 3 15.2 48HCDA04 1200 160 35.6 26.3 /2 GAS GE 1 .7 20 25 208/3/60 650 <br /> SD SMOKE DETECTOR ROUTE CONDENSATE PIPING THROUGH ROOF TO INDIRECTLY <br /> DRAIN ABOVE MOP SINK. NOTES: �� p <br /> FLEXIBLE DUCT 1 . FURNISH AND INSTALL NEW ROOFTOP UNIT AND MANUFACTURER-APPROVED 14" ROOF CURB. <br /> O3 FLEXIBLE AIR DUCTS SHALL BE TESTED IN ACCORDANCE WITH 2. PROVIDE UNIT WITH ECONOMIZER WITH FAULT DETECTION & DIAGNOSTICS, BAROMETRIC RELIEF DAMPER, AND THROWAWAY FILTERS. ECONOMIZER AND <br /> VOLUME DAMPER UL 181. SUCH DUCTS SHALL BE LISTED AND LABELED AS OUTSIDE AIR DAMPERS SHALL HAVE MOTORIZED DAMPERS THAT COMPLY WITH TITLE 24 REQUIREMENTS. <br /> FD FIRE DAMPER CLASS 0 OR CLASS 1 FLEXIBLE AIR DUCTS AND SHALL BE 3. VERIFY ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING EQUIPMENT. <br /> INSTALLED IN ACCORDANCE WITH LOCAL MECHANICAL CODE. <br /> FLEX DUCT RUNS SHALL BE LIMITED IN LENGTH TO NO MORE <br /> DkCEILING SUPPLY AIR DIFFUSER THAN 5'-0". ASHRAE 62.1 O.A. CALCULATIONS <br /> o O PROVIDE WALL-MOUNTED ELECTRIC AIR CURTAIN ABOVE AREA OCCUPANCY CFM/PERSON SUBTOTAL SQUARE FEET CFM/SQFT SUBTOTAL TOTAL CFM PROVIDED BY <br /> CEILING RETURN AIR GRILLE DOOR/WINDOW. SEE ARCHITECTURAL DRAWINGS FOR <br /> ADDITIONAL INFORMATION. PRODUCTION 9 7.5 67.50 575 0.18 103.5 171.0 RTU-1,2 <br /> SIDEWALL AIR DIFFUSER OR GRILLE <br /> NEW DUCTWORK O5 6"0 EXHAUST DUCT OUT THROUGH ROOF. MAINTAIN MINIMUM OF <br /> 10 FEET FROM ANY OUTSIDE ARE INTAKES. <br /> EXISTING DUCTWORK <br /> O INSTALL OWNER-PROVIDED WALK-IN COOLER CONDENSING UNIT <br /> - D - CONDENSATE DRAIN ON ROOF. REFRIGERANT PIPING FROM COOLER TO REMOTE AIR BALANCE SCHEDULE <br /> - G - GAS PIPING CONDENSER ONTHE ROOF PROVIDED BY CONTRACTOR PER EXHAUST AIR FLOW <br /> MANUFACTURER, EXHAUST UNIT PROVIDED BY O.A. FLOW (CFM) <br /> RECOMMENDATIONS. VERIFY EXACT ROUTING (CFM) ( ) <br /> D PIPE TURNING DOWN AND ROOF PENETRATION LOCATION IN FIELD. <br /> *EF-1 75 RTU-1 100 <br /> _____0 PIPE TURNING UPRTU-2 100 <br /> L O7 INSTALL OWNER-PROVIDED ICE MAKER CONDENSING UNIT ON - - <br /> T BALL VALVE GNICH <br /> ROOF. REFRIGERANT PIPING FROM ICE MAKER TO REMOTE TOTAL EXHAUST 75 TOTAL O.A. 200 /� <br /> 04 GATE VALVE CONDENSER ON, THE ROOF PROVIDED BY CONTRACTOR PER * FAN TO OPERATE ON AN INTERMITTENT BASIS. ARCHITECTURE <br /> ` e CONNECTION OF NEW TO EXISTING MANUFACTURERS RECOMMENDATIONS. VERIFY EXACT ROUTING S T U D O <br /> AND ROOF PENETRATION LOCATION IN FIELD. AN OREGON LIMITED LIABILITY COMPANY <br /> CHECK VALVE <br /> O UNDERCUT DOOR 1" FOR MAKEUP AIR. AIR DEVICE SCHEDULE <br /> CL <br /> GAS COCK <br /> --d4- UNION O FURNISH AND INSTALL GALVANIZED STEEL DUCTWORK, SIZES AS SYMBOL S1 S2 R1 <br /> PRESSURE GAUGE SHOWN ON DRAWING. SIZES SHOWN ARE CLEAR, INSIDE DUCT SIZE 10"o 6"0 16"0 <br /> DIMENSIONS. ALL DUCTWORK SHALL BE PROVIDED WITH 1001 SE SANDY BLVD, SUITE 100 <br /> MINIMUM R-6 INSULATION. BOOT SIZE 10"o 6"0 22"x22" <br /> STRAINER PORTLAND, OR 97214 <br /> AFF ABOVE FINISHED FLOOR 1 p 3" PVC/CPVC INTAKE AND 3" PVC/CPVC EXHAUST FROM GAS FACE SIZE 24"x24" 12 x12 24"x24" V. 503.552.9079 <br /> 2 AIR DEVICE # S - SUPPLY WATER HEATER UP TO ROOF. COMBINE RIGHT BEFORE ROOF DESIGN MFG. TITUS TITUS TITUS F. 503.241.7055 <br /> S1 R - RETURN PENETRATION WITH CONCENTRIC VENT KIT. WATER HEATER MODEL NO TMS TMS 350RL WWW.GNICHARCH.COM <br /> 100 CFM E - EXHAUST PROVIDED AND INSTALLED BY OTHERS. TYPICAL OF 2. FINISH WHITE WHITE WHITE <br /> N <br /> 01.13.21 <br /> AIR CURTAIN SCHEDULE <br /> U <br /> DESIGNATION AC-1,2,3 A-4 �pVIESS1cli D <br /> R_0r 'TC <br /> -0 LENGTH 36" 48" <br /> MANUFACTURER GLOBAL IND. GLOBAL IND. 21 <br /> L "�� �.WW. <br /> MODEL FM-1209-2-246608 FM-1212-2-246609 s cHA��� <br /> OF CAS-'FCS <br /> AIR FLOW (CFM) 670/815 670/815 <br /> VOLTAGE 120/10 120/10 <br /> N MOTOR (WATTS) 255 320 <br /> U <br /> Q AMPS 2.1 2.65 <br /> 2 <br /> co <br /> WEIGHT 28.5 28.5 <br /> PROVIDE FACTORY PROVIDE FACTORY <br /> REMOTE CONTROL, REMOTE CONTROL, Q <br /> ACCESSORIES 2-SPEED BLOWER 2-SPEED BLOWER CD <br /> MOTOR, AND FACTORY MOTOR, AND FACTORY O <br /> MOUNTING ACCESSORIES MOUNTING ACCESSORIES N <br /> AC 0 <br /> co 4 1 cn <br /> o / O o O VENTILATION FAN SCHEDULE <br /> \ DESIGNATION EF-1 <br /> ® O <br /> ® \ AC APPLICATION BATHROOM EXHAUST W 0 <br /> o / I <br /> 3 4 <br /> MANUFACTURER COOK <br /> mix <br /> S1 <br /> MODEL GC-148 LL <br /> 1 300 U EF AIR FLOW (CFM) 75 O <br /> I ®® 08 s1 5 <br /> I Z <br /> OR10'-0' m TYPICAL 350 ® 1 STATIC PRESSURE 0.4 , N <br /> O9 2 <br /> CU <br /> S2 `� O <br /> I MOTOR (HP OR WATTS) 29W NLO <br /> 1 50 WEIGHT 12 0 O `0 U <br /> s1 N I U i° p O <br /> 0 \ ROOF / 300 0 ROOF MCA — r 1 N >' LO <br /> Ln <br /> di C/, ACCESS RTU °0 ACCESS g v O� m N <br /> aXD <br /> LADDERLADDER O NOTES: PROVIDE SPEED m O Q U 1 D CONTROL SWITCH AND O U -RTU-1,2 CONTROL NOTES MECHANICALLY O U U <br /> , \ / \ aD <br /> 3 AL 1 T <br /> ACTUATED,DAMPERW LEAK � No O O <br /> \ / <br /> RTU �C \ N N N O <br /> 12 <br /> ISSUED FOR PERMIT: <br /> 0 O <br /> 7 I R1 Ac42 01 .13.2021 <br /> / 1100 4 4 <br /> Cz <br /> NOTE: ROOF PARAPET IS <br /> U 1 S1 R1 S1 S1 S1 <br /> o GREATER THAN 42" ABOVE <br /> ROOF LEVEL, NO FALL I 30 300 D 400 400 00 <br /> PROTECTION REQUIRED. I 0 10 <br /> 10 -7I 00 <br /> Z 0 D O— LV.. DATE: DESCRIPTION: <br /> o / <br /> U <br /> a AC <br /> ' 4 2 <br /> \ / MECHANICAL PLAN SHEET NAME: <br /> Cn <br /> MECHANICAL ROOF PLAN \ 1 N — /— N <br /> 1 SCALE1 1/4" = V-0" / SCALE. 1/4 - 1 0 <br /> 00 00 <br /> MECHANICAL PLAN <br /> N <br /> (6 <br /> CU <br /> coC <br /> Cn <br /> 0 <br /> co I %o&4S E SHEET NUMBER: <br /> EnpineerinInc.F 4g M1 . 0 <br /> 796 Merus Court T 636.349.1600 <br /> s <br /> St.Louis,MO 63026 F 636.349.1730 <br /> ©2020 DB Franchising USA,LLC <br />