My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
18700
>
1600 - Food Program
>
PR0161810
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:36 AM
Creation date
10/12/2021 8:06:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0161810
PE
1625
FACILITY_ID
FA0000078
FACILITY_NAME
GEORGE'S COUNTRY CAFE
STREET_NUMBER
18700
Direction
N
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
APN
05131001
CURRENT_STATUS
01
SITE_LOCATION
18700 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name and Address: GEORGE'S COUNTRY CAFE, 18700 N HWY 88 , LOCKEFORD 95237 <br />Food Program Official Inspection Report <br /> #38 Approved / Sufficient Ventilation and Lighting <br />OBSERVATIONS: Back light in kitchen back storage area was not working and light cover was open. Provide working lights <br />with light shield within 1 week. <br />CALCODE DESCRIPTION: Exhaust hoods shall be provided to remove toxic gases, heat, grease, vapors and smoke and be approved by <br />the local building department. Canopy-type hoods shall extend 6" beyond all cooking equipment. All areas shall have sufficient ventilation <br />to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window, an air shaft, or a <br />light-switch activated exhaust fan, consistent with local building codes. (114149, 114149.1) Adequate lighting shall be provided in all areas <br />to facilitate cleaning and inspection. Light fixtures in areas where open food is stored, served, prepared, and where utensils are washed <br />shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br />OBSERVATIONS: The 1 dr True reach-in at the front counter and the two Bev-Air reach-in coolers at the bar were lacking <br />thermometers. Provide accurate thermometers in easily visible locations within 2 weeks. <br />CALCODE DESCRIPTION: An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br />available to the food handler. A thermometer +/- 2 #F shall be provided for each hot and cold holding unit of potentially hazardous foods <br />and high temperature warewashing machines. (114157, 114159) <br /> #41 Plumbing Maintained; Approved Back Flow Device <br />OBSERVATIONS: The 2 comp sink discharge pipes had plastic bags wrapped around them. Remove bags today. <br /> <br />The discharge pipes for the kitchen ice machine, walk-in, dishwasher, and server station soda machine had no air gap from <br />the floor sinks. Provide 1 in. minimum air gap between the discharge pipes and floor sinks within 2 weeks. <br />CALCODE DESCRIPTION: The potable water supply shall be protected with a backflow or back siphonage protection device, as required <br />by applicable plumbing codes. (114192) All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br />ordinances, shall be maintained so as to prevent any contamination, and shall be kept clean, fully operative, and in good repair. Any hose <br />used for conveying potable water shall be of approved materials, labeled, properly stored, and used for no other purpose. (114171, <br />114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #43 Toilet Facilites Clean/ Supplied/ Maintained <br />OBSERVATIONS: The employee restroom did not have any toilet paper in dispenser. Provide today. <br />The male restroom right urinal was not working. Repair/replace within 1 month. <br />CALCODE DESCRIPTION: Toilet facilities shall be maintained clean, sanitary and in good repair. Toilet rooms shall be separated by a <br />well-fitting self-closing door. Toilet tissue shall be provided in a permanently installed dispenser at each toilet. The number of toilet <br />facilities shall be in accordance with local building and plumbing ordinances. Toilet facilities shall be provided for patrons: in <br />establishments with more than 20,000 sq ft. establishments offering on-site liquor consumption. (114250, 114250.1, 114276) <br />Page 3 of 4EHD 16-23 Rev. 09/16/2020 Food Program OIR <br />FA0000078 PR0161810 SC001 10/07/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.