My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WET -PIPE SPRINKLER SYSTEMS <br />Section 15360 <br />15-1207 <br />soffits shall be of manufactures standards as selected by the architect. <br />C. Spare Sprinkler Heads: Furnish spare sprinkler heads placed in an emergency <br />cabinet. For each cabinet provide one sprinkler wrench. The cabinet will be of <br />No. 20 gauge pressure steel with red lacquer finish complete with manufacturer <br />standard labeling. The spare heads shall be representative of, and in proportion <br />to, the number of each type and temperature of heads installed. Locate cabinet <br />where shown on plans or as directed by owner. <br />2.02 PIPE AND FITTINGS <br />A. Pipe fittings for installation below ground shall be cement lined, cast iron <br />conforming to the requirements of American Water Works Association Standard <br />Specification for cast iron special castings, Class D, 150 Ib., AWWA C151 <br />mechanical or push -on joint; with AWWA C104 cement -mortar lining, "Blue Brut" <br />or PVC pressure pipe AMA C900, UL approved for fire line service. If PVC <br />premastering pipe is used with mechanical joint fittings, install according to <br />manufacturer's requirements and recommendations. <br />B. Fire sprinkler piping, from base of riser to 5-0" outside building (Below ground): <br />C. Pipe: Acceptable piping materials are Class 50 cement -lined ductile iron with a <br />working pressure of 250 psi per NFPA 24. All piping shall be listed for fire <br />protection service. <br />D. Fittings: Fittings shall be rated to a minimum of 250 psi and meet applicable <br />requirements of ANSI/AWWA and NFPA 24. <br />E. All materials shall comply with NFPA / ANSI & AWWA <br />F. The flange and spigot piece at the base of the riser shall be secured to the <br />underground elbow at the base of the riser with two %" stainless steel tie rods for <br />6" riser (for underground supply piping). <br />G. Pipe for installation above ground shall conform to ASTM A 795, A 53, or A135. <br />Thin wall pipe with grooved fittings and couplings may be used for pipe 2" and <br />larger. Piping for sizes 1'/2' and smaller shall be Schedule 40 pipe with welded, <br />grooved or screwed fittings. No thin wall pipe shall be used in conjunction with <br />screwed fittings. <br />H. Gate valves shall be approved rising stem type (OS&Y). All shut off valves shall <br />be equipped with tamper switches. <br />I. All exposed valves shall be chained to prevent accidental shutting of the valves. <br />J. Fire sprinkler riser shall comply with all applicable codes. Supports, Anchors, <br />Bracing — See All Sections 21 05 29 and 21 05 48. <br />K. Piping Penetration Auxiliaries: Conform to NFPA 13 and the following: <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.