My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PACKAGED AIR CONDITIONING <br />UNITS <br />Section 15855 <br />15-1207 <br />3. The coils shall be non-ferrous construction with aluminum fins mechanically bonded to <br />durable copper tubes. Coils shall be leak tested under water with minimum 200 psi air at <br />the factory prior to installation in the units. <br />4. The compressor shall be resiliently mounted and have built- in, three -mode crankshaft <br />lubrication; crankcase heater; discharge temperature limiter; and current- and temperature - <br />sensing motor overloads. <br />5. The cooling system shall be protected by high and low pressure switches, filter dryer, oil <br />failure switch, and a five-minute, compressor, timed off cycle controller (anti- recycle timer), <br />and evaporator coil frostat that shall disable cooling when temperatures on the evaporator <br />coil reach 10 degrees or below. Mechanical cooling will start again when temperatures on <br />the evaporator coil rise to 50 degrees or above. <br />B. Cabinet: <br />1. Unit cabinet shall be constructed of phosphated, zinc --coated, pre --painted steel capable of <br />with standing 500 hours in salt spray. <br />2. Normal service shall be through multiple removable cabinet panels. <br />3. The unit shall be constructed on a rust proof unit base that has an externally trapped, <br />integrated sloped drain. <br />4. Evaporator fan compartment top surface shall be insulated with a minimum '/2 inch thick, 1 <br />'/2" density, flexible fiberglass insulation bonded with a phenolic binder, neoprene coated on <br />the air side. <br />5. Gas heat compartment shall be insulated with aluminum foil -faced fiberglass insulation. <br />C. Service Access: <br />1. All components, wiring, and inspection areas shall be completely accessible through <br />removable access panels. <br />2. Hinged access panels shall be provided at access to filter section, fan section, compressor <br />section, heat section, and controls. <br />D. Supply Air Blowers: <br />1. The evaporator fan motor shall be a multi -speed, belt -drive, as shown on equipment <br />drawings. <br />2. Supply air blower to be controlled via a factory installed variable frequency drive. <br />3. Fan wheel shall be made from steel, be double -inlet type with forward curved blades with <br />corrosion resistant finish. <br />4. Fan wheel shall be dynamically balanced. <br />5. Supply blower motors shall be thermally protected and meet the US EPACT 1992 Code. <br />6. Supply blower motors to be high efficiency option. <br />E. Condenser Fans: <br />1. Condenser fan shall be direct drive propeller type with aluminum blades riveted to corrosion <br />resistant steel spiders, be dynamically balanced, and discharge air vertically. <br />F. Condenser Coil Guard: <br />1. Factory installed guard shall be manufactured from minimum 18 gauge expanded steel. <br />2. The guards shall be powder coated to match the unit color. <br />3. Guard open area shall be between fifty percent and sixty percent. <br />G. Base unit controls: <br />1. Unit to be provided with base electromechanical controls. <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.