My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DUCTLESS SPLIT SYSTEM <br />AC UNITS <br />Section 15865 <br />15-1207 <br />F. Oil Loops and Double Risers: Provide to assure successful operation. <br />2.03 PKA SERIES DUCTLESS SPLIT SYSTEM AIR CONDITIONER <br />A. General: <br />1. The Air Conditioner system shall be a Mitsubishi Electric split system with <br />Variable Speed Inverter Compressor technology. The system shall consist of a <br />wall mounted indoor section with wired, wall mounted controller and a horizontal <br />discharge, single phase outdoor unit. <br />2. Provide model and capacity to be as scheduled on drawings. <br />a. Cooling performance shall be based on 80°F DB, 67°F WB for the indoor <br />unit and 95°F DB, 75°F WB for the outdoor unit. <br />3. A dry air holding charge shall be provided in the indoor section. <br />4. The outdoor unit shall be pre -charged with R -410a refrigerant for 70 feet of <br />refrigerant tubing. <br />a. Where required, provide charge system with extra refrigerant. <br />5. System efficiency shall meet or exceed scheduled SEER. <br />B. Indoor Unit Cabinet: <br />1. The indoor unit cabinet shall be wall mounted by means of a factory supplied <br />mounting plate. The cabinet shall be formed from high strength molded plastic <br />with front panel access for filter. <br />2. The indoor unit shall be factory assembled, wired and tested. Contained within <br />the unit shall be all factory wiring and internal piping, control circuit board and fan <br />motor. <br />3. The unit in conjunction with the wired, wall mounted controller shall have a self- <br />diagnostic function, 3 -minute time delay mechanism, an auto restart function, and <br />a test run switch. <br />4. Indoor unit and refrigerant pipes shall be purged with dry nitrogen before <br />shipment from the factory. <br />C. Indoor Unit Fan: <br />1. The evaporator fan shall be high performance, double inlet, forward curve, direct <br />drive sirocco fan with a single motor <br />2. The fans shall be statically and dynamically balanced and run on a motor with <br />permanently lubricated bearings. <br />3. The indoor fan shall have fan speeds as listed on drawings. <br />a. Unless noted otherwise, set fan speed on low. <br />D. Indoor Unit Vane <br />1. There shall be a motorized horizontal vane to automatically direct air flow in a <br />horizontal and downward direction for uniform air distribution. The horizontal <br />vane shall significantly decrease downward air resistance for lower noise levels, <br />and shall close the outlet port when operation is stopped. <br />2. There shall also be a set of vertical vanes to provide horizontal swing airflow <br />movement selected by remote control. <br />E. Indoor Unit Filter: <br />1. Return air shall be filtered by means of an easily removable washable filter. <br />3 <br />