My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DUCT ACCESSORIES <br />Section 15910 <br />15-1207 <br />2. Sidewall (ID E2 & R2): <br />a. Titus return grille, model 355ZRL or equal. <br />b. 1/2" blade spacing <br />c. 0° Fixed Deflection Blades <br />d. Provide with blades parallel to the long dimension. <br />e. Provide with type #1 border for surface mount. <br />C. Transfer Air Grilles: <br />Ceiling (ID TA1): <br />a. Titus return grille, model 350RS or equal. <br />b. 3/4" blade spacing <br />c. 35° Fixed Deflection Blades <br />d. Provide with full 24"x24" ceiling module and #3 border. <br />e. Provide with type #1 border for surface mount. <br />2. Sidewall (ID TA2): <br />a. Titus return grille, model 350ZRL or equal. <br />b. 3/4" blade spacing <br />c. 0° Fixed Deflection Blades <br />d. Provide with blades parallel to the long dimension. <br />e. Provide with type #1 border for surface mount. <br />2.03 COMBINATION FIRE/SMOKE DAMPERS <br />A. Acceptable Manufacturers: <br />1. Ruskin <br />2. Greenheck <br />3. Nailor <br />4. Air Balance <br />B. General: <br />1. Provide combination fire/smoke dampers at fire rated/smoke partitions and walls in <br />accordance with NFPA 90A and NFPA101. Refer to Drawings and diagrams. <br />2. Each combination fire/smoke damper shall be 1-1/2 hour fire rated under UL 555S, <br />and further classified by Underwriter's Laboratories as a leakage rated damper for <br />use in smoke control systems under the latest version of UL 555S, and bear a UL <br />label attesting to same. <br />3. Damper manufacturer shall have tested, and qualified with UL and CSFM a complete <br />range of damper sizes. Having a single damper size tested and UL qualified is not <br />acceptable. The leakage rating under UL 555 S shall be no higher than Leakage <br />Class 11 (10 CFM/sq ft at 1" w.g.). <br />4. As part of the UL qualification, dampers shall have demonstrated a capacity to <br />operate (open and close) under HVAC system operating conditions, with pressures <br />of at least 4" inches w.g. in the closed position, and 3,000 fpm air velocity in the open <br />position. <br />5. Dampers and their operators shall be qualified under UL 555 S to an elevated <br />temperature of 250 degrees F with electric operators. Damper operators shall be <br />installed by the damper manufacturer at time of fabrication. The assembly shall <br />meet UL 555 S qualifications for dampers and operators. <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.