My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITE ELECTRICAL WORK, GENERAL <br />REQUIREMENTS <br />Section 16000 <br />15-1207 <br />outlets. In all cases where new wires are required, shown, or specified to be installed in <br />existing conduits, if same cannot be installed, new conduits shall be provided therefore as <br />directed. <br />3. Existing switchboards, motor control centers, bus duct, and panelboards which are required <br />to be extended, altered or modified under the Work of this Division shall be provided with <br />new sections, bus extensions, and all necessary hardware for a complete and operating <br />system,. Maintain all testing agency certifications. <br />4. Attention is called to the fact that all new conduit, wiring, and apparatus shown or specified <br />shall be connected to existing systems so as to function as complete units. <br />5. All conduits, electrical apparatus, and similar items, in place and not shown or specified to be <br />reused or which will not be essential to functioning of various systems when Work is <br />completed, shall be removed. No existing material shall be reinstalled or reused, unless <br />shown or specified. Concealed conduits which are not shown or specified to be reused and <br />become exposed due to construction changes shall be removed to nearest available <br />accessible reused outlets. <br />F. Protection: In performance of Work, protect existing facility and protect Work of other Sections <br />as well as Work of this Section from damage. <br />3.2 PERFORMANCE: <br />A. Excavation and Backfilling: <br />1. As specified in Earthwork Section. <br />2. Provide all necessary shoring, sheeting, pumping as part of Work of this Division. Excavate <br />and backfill as required for installation of Electrical Work. <br />3. In asphalt or concrete paved areas, backfill only to subgrade level. <br />4. Support conduit for entire length on undisturbed original earth. Minimum conduit depth of <br />pipe crown shall be two feet (2') below finished or natural grade. <br />5. !?estore all surfaces, rcad.rays, walks, curbs, walls, existing underground installations, and <br />other construction or improvements damaged by installation of Electrical Work, to original <br />condition in an acceptable manner. <br />6. Maintain all warning signs, barricades, flares, and lanterns as required. <br />B. Concrete: <br />1. Concrete for conduit encasement shall be a mixture of approximately 50% sand and 50% <br />rock, which will pass a 1 inch square screen, and four sacks of cement to the cubic yard of <br />finished concrete. It shall be thoroughly consolidated. <br />2. Concrete used for encasement of electrical conduits shall contain red oxide in mix, five (5) <br />pounds per cubic yard. <br />3. Concrete for other than concrete encasement shall be as specified in Division 3. <br />C. Sleeves, Chases, and Concrete Inserts: <br />1. This Division shall provide, to cause no delay, all required sleeves, chases, concrete inserts, <br />anchor bolts, and similar items before concrete is placed, and be responsible for correct <br />location and installation of same. <br />2. Sleeves and chases are prohibited in structural members, except where shown or as <br />otherwise wise approved ins writing. <br />12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.