My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE MASONRY UNIT <br />Section 04300 <br />15-1207 <br />PART 1 - GENERAL <br />1.01 INCLUSION OF OTHER CONTRACT DOCUMENTS <br />A. The General Conditions, Supplementary Conditions and Division 1 are fully applicable to this <br />Section, as if repeated herein. <br />1.02 RELATED WORK SPECIFIED ELSEWHERE <br />A. Section 01400, Testing Laboratory Services. <br />B. Section 03000, Site Concrete <br />C. Section 03200, Concrete Reinforcement. <br />D. Section 03300, Cast -In -Place Concrete. <br />E. Section 05100, Structural Steel. <br />F. Section 07180, Water Repellants & Anti -Graffiti Coatings. <br />G. Section 07900, Joint Sealants, for rod and sealant at control and expansion joints. <br />H. Section 09900, Painting. <br />1.03 QUALITY ASSURANCE <br />A. Use only newly manufactured products, unless existing materials or products are specifically <br />shown otherwise on the Drawings to be salvaged and re -used. <br />B. Use materials and products of one manufacturer whenever possible. <br />C. All materials, components, assemblies, workmanship and installation are to be observed by <br />the Owner's Project Inspector. Work not so inspected is subject to uncovering and <br />replacement. <br />D. Special Inspection: Coordinate with Owner's special inspector of building structural masonry <br />construction in compliance with 2013 CBC Section 1704A.2. See Section 04300, Article 1.09 <br />for additional requirements. <br />E. Tests: See Section 01400 and Section 04300 Article 1.08 for required structural masonry <br />tests. <br />F. Pre -Installation Conference: Convene conference among Owner's Representative, <br />Contractor, Architect, Structural Engineer, Project Inspector and Special Inspector at least <br />one week prior to beginning work of this Section. Discussion is to include, but not limited to, <br />the requirements for the Mock-up, and confirmation of the location and construction of control <br />/ expansion joints. At the Owner's option, a third party expert in CMU construction may be <br />
The URL can be used to link to this page
Your browser does not support the video tag.