METAL DECK <br />Section 05300 <br />15-1207 <br />offered under provisions of this specification shall conform to general configuration and <br />dimensions and shall have geometric properties equaling or exceeding those shown. <br />B. Acceptable Manufacturers: <br />1. ASC Steel Deck <br />2. Verco Manufacturing Company <br />3. Accepted equal. <br />2.02 MATERIALS <br />A. Sheet Steel: Steel decking and flashing shall be formed from steel sheets conforming to <br />ASTM A-653, SS Grade 33, with minimum yield strength of 33,000 psi. Before forming, the <br />steel shall receive a protective metal coating of zinc conforming to ASTM A653 G60 wiped <br />coating, and to Federal Specification QQ-S-775 C, Type I, Class E, with a minimum of 0.502 <br />ounce zinc per square foot, on decks not exposed to the exterior environment. Decks <br />exposed to the exterior in the completed project shall have G90 wiped coating with a <br />minimum of .80 ounce zinc per square foot. <br />B. Deck Sections <br />1. Deck units shall be supplied in lengths to span over at least 2 supports where layout <br />permits. All single span units, to receive concrete fill, shall have temporary mid -span <br />shoring. <br />2. All deck units shall be provided with either an interlocking side lap or a lapping type <br />side lap. <br />3. Venting Devices: All deck sections to receive a poured fill topping, shall be vented <br />using individual separating clips of type, style and spacing recommended by deck <br />manufacturer (space no more than 48" o.c. or a two per deck span) or by built -in- <br />venting slot formed as an integral part of deck profile. Venting slots are required only <br />in non -cellular deck. Tabs shall be turned up into deck so that they cannot be used for <br />hangers. Provide three rows of slots at 2'-0" on centers in three foot wide deck <br />sections. <br />4. Acoustical Deck: Where specified on Drawings, provide deck conforming to Article <br />2.01A & 2.01 B (including insulation batts) and having vertical legs provided with holes. <br />Noise reduction Coefficient of complete assemble, as installed shall not be less than <br />0.60. <br />5. Flashing and Closure Plates: Provide 18 gauge, or match decking gage whichever is <br />heavier, zinc coated continuous flashing for deck units as detailed, or as required, at <br />ends and sides, at openings and at deck perimeter to contain fill. Flashing shall be <br />detailed and installed to prevent concrete leakage. <br />6. Reinforcing at openings and penetrations: Provide reinforcing at all openings and <br />penetrations per plans and standard details. <br />7. Paint: Zinc dust -zinc oxide primer, Federal Specifications TT P-64, Type II. <br />C. Automatic End Welded Studs Used as Shear Connectors or Headed Stud Anchors for <br />Concrete Embeds: <br />1. Automatic end welded studs shall be Nelson Granular Flux -filled Shear Connector or <br />Anchor Studs (or accepted equal). <br />2. Studs shall be manufactured of cold -finished carbon steel which conforms to ASTM <br />19 <br />