Laserfiche WebLink
FINISH CARPENTRY AND <br />MILLWORK <br />Section 06200 <br />15-1207 <br />3.03 INSPECTION <br />A. Prior to installation of the work of this Section, carefully inspect and verify that the installed <br />work of all other trades is complete to the point where this installation may properly <br />commence. <br />B. Verify that specified items may be installed in accordance with the approved design. <br />C. In the event of discrepancy, immediately notify the Architect. Do not proceed in discrepant <br />areas until discrepancies have been fully resolved. <br />3.04 PROTECTION <br />A. Protect work and materials of this Section and other sections prior to and during installation, <br />and protect the installed work and materials of other trades. <br />B. In the event of damage, make all repairs and replacements necessary to the approval of the <br />Architect at no additional cost to the Owner. <br />C. Exposed finish shall be free from scratches, dents, permanent discolorations and other <br />defects in workmanship or material. <br />3.05 INSTALLATION <br />A. General: Do not install millwork until wet operations are completed; the concrete, masonry <br />and plaster work has thoroughly dried and the millwork has been primed or sealed in an <br />approved manner. <br />B. Installation of finish carpentry and millwork shall conform to the applicable requirements of <br />the Architectural Woodwork Standards, WI. <br />C. Interior Frames: Install plumb, square and true, securely wedged and anchored to structure. <br />Countersink fasteners. <br />D. Trim Members: Install level, plumb and true, with member neatly and accurately scribed in <br />place. Install trim in single lengths, running trim in as long a length as practical for species <br />specified. Butt joints to be back -beveled, exterior and interior angles mitered. <br />E. Fastening: All nails or screws to have required penetration into holding member per Title 24, <br />Table 2304.9.1. <br />1. Exterior Trim: 10d nails or less, use finish nails set 1/16 inch below face, without putty. <br />10d to 20d nails, use common nails driven flush without hammer marks and putty. 20d <br />or over, use common nails driven flush without hammer marks and putty. <br />2. Interior Trim: Set nails or appropriate screw fasteners 1/16 inch below face, with putty. <br />No putty where finish will be clear. <br />3. Exterior Plywood: Nails long enough to penetrate structural backing 1 inch. Use <br />galvanized box nails, driven flush without hammer marks. <br />4. Interior Plywood: Install with grain texture vertical, with edges and ends occurring only <br />over bearings. Use aluminum or stainless steel finish nails in 8d size for 5/8 inch thick <br />plywood and 6d for 3/8 inch thick plywood. Nail 6 inches on -center along all sheet <br />5 <br />