FOOD SERVICE <br />EQUIPMENT <br />Section 11400 <br />15-1207 <br />B. All food service equipment shall be installed per the "Guidelines for Seismic Restraints of <br />Kitchen Equipment" by the Sheet Metal and Air Conditioning Contractors National Association <br />(SMACNA). <br />C. All food service equipment shall comply with the standards of The California Code of <br />Regulations, Title 24, Part No. 2. <br />D. All food service equipment shall comply with the current California Energy Commission <br />Appliance Efficiency Regulations. <br />E. Equipment in the following schedule is listed by Item Numbers shown on Drawings. <br />1. SCHEDULED ITEMS: <br />ITEM 1 - AIR CURTAIN (1 REQ'D) <br />Mars Air Systems Model LPV248-1 U <br />High Velocity Series 2 Air Curtain, for NSF Certified 42" wide door, Unheated, 115v/60/1 -ph, Battleship <br />Gray powder coated cabinet (Custom Production Color) cETLus, CE, NSF <br />Accessories <br />1 ea. 5 year warranty, standard <br />1 ea. Level 1 control package, line voltage, combination plunger/roller door limit <br />switch, for instant on/off control, use on any type of door <br />ITEM 2 - WALK-IN FREEZER (1 REQ'D) <br />FABRICATED ITEM - RMI <br />Assembly shall consist of one (1) Refrigerator compartment; 11'-5" Deep x 8'-5" Wide x 8'-0" high Clear <br />interior dimensions. Assembly to form the configuration as shown on the drawings. Assembly shall be <br />furnished as herein specified. And as prepared by RMI. <br />Assemblies shall be N.S.F (Standard 7) approved and formed in the configuration as <br />shown on the contract drawings. Assemblies shall meet California Code of Regulations <br />Title 20 Sections 11601 through 1608 dated July 2006 Appliance Efficiency Regulations. <br />2. Panel Construction: Shall consist of exterior and interior die formed metal panels formed <br />to insure proper size. Section edges must have lineup pines and double row of closed <br />cell gaskets to insure panel alignment and proper seal at each joint. Corner panels to be <br />90 degree angles 12 inches in each direction. (No Wood Construction will be accepted). <br />3. Insulation: Walls and Ceiling 4" of "foamed -in place urethane insulation shall be used <br />with a thermal conductivity of not more than 0.118 BTU per hour per square foot. U <br />Factor shall not exceed 0.030. The insulation shall be rated self extinguishing and fire <br />retardant type as specified by UL. Insulation must remain stable at temperatures up to <br />260°F. Floor to be same as above except Heavy Duty reinforced for cart storage <br />capable to withstand 500 pound point load with no deflection. <br />4. Section Fasteners: All wall, floor and ceiling sections joints shall be fastened together <br />with steel cam action speed locks. These fasteners shall not exceed a 46" on center <br />spacing. All locks shall be actuated from inside with a standard hex type Allen wrench. <br />13 <br />