My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOOD SERVICE <br />EQUIPMENT <br />Section 11400 <br />15-1207 <br />a. Door hinges: (3) per door, self-closing and chrome plated Kason No. 1256 Cam - <br />Lift. <br />b. Door Pulls: Chrome plated Kason No. 1229C with inside safety release. <br />C. Door Closure: Kason No. 1094. <br />d. Trim Molding: Where unit abuts the building wall they shall be trimmed with a <br />closure strip to match the exterior walk-in wall finish. Provide removable "drop- <br />in" closure panels at ceiling. Provide vertical closure strips at all building wall <br />junctures. <br />e. Each compartment shall be provided with a high temperature alarm system, <br />Modular Corporation model No. 75 FLUSH mounted. This unit to be provided <br />complete with built-in N/O & N/C dry contacts and pulse output for remote <br />notification. <br />f. Dial Thermometer: Provide one (1) 4" dia. built into each walk-in door panel. <br />g. Pressure Relief Port: One (1) for each compartment Kason No. 1830 (heated at <br />freezer only. <br />h. Strip Curtains: each walk-in door shall have polyester reinforced clear vinyl strip <br />curtains. <br />i. Entrance Doors: Each door shall have a 1/8" thick sheet aluminum diamond plate <br />kick panel T-0" high on the exterior and interior door panels and adjacent door <br />jambs. <br />j. The wall panels exposed to the kitchen shall have a 16 gauge stainless steel rub <br />rail. <br />k. Provide a stainless steel interior and exterior coved toe base. <br />I. Provide necessary backing in wall panel for the attachment <br />M. Floor to be heavy duty type to support cart traffic. <br />9. This assembly shall be installed by factory personal and or factory approved installers <br />with written certification provided by the manufacturer to the Architect and Consultant. <br />10. Walk-in assembly shall be installed into a recessed area as shown on the drawings. <br />Kitchen Equipment Contractor is to verify finishes and thickness of kitchen floor and <br />allow for proper clearance at walk-in door. <br />ITEM 2.1 - COLD STORAGE SHELVING (4 REQ'D) <br />Metro Model A2148NK3 <br />Super Adjustable Super Erecta® Shelf, wire, 21" W, 48" L, Metroseal 3 (corrosion -resistant) finish, <br />corner release system, with Microban® antimicrobial protection, NSF. Shelving to be 4 tier units with <br />the bottom shelf at a minimum of 12" above finished floor. <br />Accessories: <br />16 ea. Super Erecta® SiteSelectTM Post, 62 9/16" H, adjustable leveling bolt, posts are grooved <br />at 1" increments and numbered at 2" increments, double grooved every 8", Metroseal 3 <br />epoxy coated corrosion -resistant finish with Microban® antimicrobial protection. <br />ITEM 2.2 - COLD STORAGE SHELVING (2 REQ'D) <br />Metro Model A2154NK3 <br />Super Adjustable Super Erecta® Shelf, wire, 21" W, 54" L, Metroseal 3 (corrosion -resistant) finish, <br />corner release system, with Microban® antimicrobial protection, NSF. Shelving to be 4 tier units with <br />the bottom shelf at a minimum of 12" above finished floor. <br />15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.