My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
750
>
1600 - Food Program
>
PR0161533
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2021 7:17:05 PM
Creation date
10/15/2021 3:39:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161533
PE
1632
FACILITY_ID
FA0001342
FACILITY_NAME
MUSD-LINCOLN SCHOOL
STREET_NUMBER
750
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22118001
CURRENT_STATUS
01
SITE_LOCATION
750 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2850
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOOD SERVICE <br />EQUIPMENT <br />Section 11400 <br />15-1207 <br />Accessories: <br />8 ea Super Erecta® SiteSelectTM Post, 62 9/16" H, adjustable leveling bolt, posts are grooved <br />at 1" increments and numbered at 2" increments, double grooved every 8", Metroseal 3 <br />epoxy coated corrosion -resistant finish with Microban® antimicrobial protection. <br />ITEM 3 - WALK-IN REFRIGERATOR (1 REQ'D) <br />FABRICATED ITEM - RMI <br />Assembly shall consist of one (1) Refrigerator compartment; 11'-5" Deep x 8'-5" Wide x 8'-0" high Clear <br />interior dimensions. Assembly to form the configuration as shown on the drawings. Assembly shall be <br />furnished as herein specified. And as prepared by RMI. <br />Assemblies shall be N.S.F (Standard 7) approved and formed in the configuration as <br />shown on the contract drawings. Assemblies shall meet California Code of Regulations <br />Title 20 Sections 11601 through 1608 dated July 2006 Appliance Efficiency Regulations. <br />2. Panel Construction: Shall consist of exterior and interior die formed metal panels formed <br />to insure proper size. Section edges must have lineup pines and double row of closed <br />cell gaskets to insure panel alignment and proper seal at each joint. Corner panels to be <br />90 degree angles 12 inches in each direction. (No Wood Construction will be accepted). <br />3. Insulation: Walls and Ceiling 4" of "foamed -in place urethane insulation shall be used <br />with a thermal conductivity of not more than 0.118 BTU per hour per square foot. U <br />Factor shall not exceed 0.030. The insulation shall be rated self -extinguishing and fire <br />retardant type as specified by UL. Insulation must remain stable at temperatures up to <br />260°F. Floor to be same as above except Heavy Duty reinforced for cart storage <br />capable to withstand 500 pound point load with no deflection. <br />4. Section Fasteners: All wall, floor and ceiling sections joints shall be fastened together <br />with steel cam action speed locks. These fasteners shall not exceed a 46" on center <br />spacing. All locks shall be actuated from inside with a standard hex type Allen wrench. <br />All socket ports shall be finished off with a '/2' diameter snap cover to match the color of <br />the panels. <br />5. Hinged Walk -In Doors: Door shall be installed as shown on the drawings. Door shall be <br />urethane insulated, flush -in fitting type 42" wide x 80" high (as shown on the drawings) <br />with triple pane 1/4" thick plate glass view windows (freezer heated). Each door <br />shall be furnished with door heater switch and mortise style lock. Door finish to be 20 <br />gauge stainless steel inside and out. Door and door section shall be listed by UL and <br />equipped with the following: <br />a. Magnetic gasket <br />b. Door closer <br />C. Polished chrome deadbolt latch and cam -lift spring-loaded hinges <br />d. Latches shall have a safety release to prevent entrapment of personnel within the <br />box. Latches also have padlocking provisions. <br />e. Bottom of door shall have a double sweep gasket. Magnetic gasket shall be of a <br />dart and ridge design that will allow for easy replacement by the end user without <br />the use of any tools. The doorjamb shall be constructed of a fully welded <br />anodized aluminum rigid frame. The perimeter of the frame shall be no less than <br />two inches wide to provide integral backing to accommodate all required <br />16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.