Laserfiche WebLink
COUNTY oe <br /> or <br /> �Placer <br /> HEALTH & HUMAN SERVICES <br /> ENVIRONMENTAL HEALTII <br /> 5. Eljen GSF system can be approved on sites with percolation rates greater than 6- <br /> minutes per inch and less than 60-minutes per inch without pressure dosing. Sites <br /> with percolation rates of 1-minute per inch to less than 6-minutes per inch and sites <br /> with percolation rates greater than 60-minutes per inch and less than 240-minutes <br /> per inch will require pressure dosing. Pressure dose design shall comply with <br /> Placer County's pressure distribution system requirements. <br /> 6. Percolation tests are required on all lots. Sizing of the system shall be based on <br /> the more restrictive loading rate of the soil texture/structure versus percolation rate. <br /> 7. If a pump tank is required for a special design, the pump tank requirements shall <br /> comply with Placer County's pump system requirements. <br /> 8. Designated leachfield areas for existing lots with no approved minimum useable <br /> sewage disposal areas shall demonstrate adequate area for gravel trenches or <br /> subsurface drip tubing prior to septic system construction permit approval. <br /> CONDITIONS OF APPROVAL <br /> 1. The owner of the property will enter into a License Agreement for Alternative <br /> Systems with the County of Placer. <br /> 2. The owner of the property will enter into a contractual agreement for provision of <br /> Operation, Monitoring and Maintenance (OM&M) with an Eljen GSF system <br /> certified service provider. <br /> 3. The owner of the property will record the requirement for ongoing OM&M on the <br /> property title. <br /> 4. The absence of Eljen GSF trained personnel to install or provide maintenance may <br /> be grounds to suspend further issuance of any new construction permits. <br /> DESIGN REVIEW <br /> The design consultant may propose the Eljen GSF system as part of the site evaluation <br /> approval process or for sites that meet the criteria and may have been approved for other <br /> supplemental treatment systems. <br /> The design consultant must submit a proposal that: <br /> 1. Is sized appropriately for waste strength, design flow and soil percolation <br /> characteristics in accordance with Environmental Health requirements and Eljen <br /> GSF system design criteria. <br /> Environmental Health ■ 3091 County Center Drive, Suite 180■ Auburn, CA 95603 <br /> (530) 745-2300 Office • (530) 745-2370 fax ■ environmental health@placer.ca.gov <br /> 0 in 12 f <br />