Laserfiche WebLink
1.FLOORS <br />a. FLOORS IN FOOD SERVICE ESTABLISHMENTS (EXCEPT IN SALES AND DINING AREAS) SHALL BE DURABLE, <br />SMOOTH, AND IMPERVIOUS TO WATER, GREASE AND ACID, AND EASILY CLEANABLE CONSTRUCTION. FLOOR <br />SURFACES IN ALL AREAS WHERE FOOD IS PREPARED, PACKAGED OR STORED, WHERE JANITORIAL FACILITIES <br />ARE LOCATED, IN ALL TOILET AND HAND WASHING AREAS AND IN QUARY TILE OR OTHER APPROVED <br />MATERIALS. FLOOR SURFACES IN ALL AREAS WHERE FOOD IS PREPARED, PACKAGED, DISPENSED, OR STORED <br />IN OPEN CONTAINERS, WHERE ANY UTENSIL IS WASHED, WHERE REFUSE OR GARBAGE IS STORED, WHERE <br />JANITORIAL FACILITIES ARE LOCATED, IN ALL TOILET AND HAND WASHING AREAS AND IN EMPLOYEE CHANGE <br />AND CLOTHING AREAS, SHALL BE AN APPROVED TYPE THAT CONTINUES UP THE WALLS OR TOE-KICKS ARE AT <br />LEAST FOUR (4) INCHES HIGH, FORMING A 3/8" MINIMUM RADIUS COVE AS AND INTEGRAL UNIT. AN APPROVEWD <br />SLIM FOOT CERAMIC, QUARRY OR METAL TOP SET BASE IN GENERALLY ACCEPTABLE. (CURFFUL 114150(a)). <br />(VINYL TOPSET RUBBER BASE IS NOT ACCEPTABLE, EXCEPT IN DINING AREAS AND AREAS WHERE FOOD IS <br />STORED UNITS ORIGINAL SHIPPING CONTAINER). <br />b. FLOOR DRAINS ARE REQUIRED IN FLOORS THAT ARE WATER FLUSHED FOR CLEANING , WHERE PRESSURE <br />SPRAY METHODS FOR CLEANING EQUIPMENT ARE USED, WHERE SLIP RESISTANT AGENTS ARE USDED N <br />FLOORS AND WHERE EXCESSIVE MOISTURE MAY ACCUMULATE. WHERE FLOOR DRAINS ARE UTILIZED, THE <br />FLOOR SURFACES SHALL BE SLOPED 1:50 (1/4" PER FOOT) TO THE FLOOR DRAINS. WHEN FLOOR DRAINS ARE <br />ADDED TO AN EXISTING ESTABLISHMENT WHERE THE FLOOR SURFACE IS NOT SLOPED, A TWO (2) FT. FLAT <br />SURROUNDING DEPRESSION/SLOPE TO THE FLOOR DRAIN MAY BE REQUIRED. (CURFFL 114150(b)(2)). <br />c. APPROVED ANTI-SLIP FLOOR FINISHES OR MATERIALS ARE ACCEPTABLE IN AREAS WHERE NECESSARY FOR <br />SAFETY REASONS, SUCH AS TRAFFIC AREAS. (CURFFL 114150(e)). HIGH PRESSURE HOT WATER CLEANING <br />SYSTEMS ARE REQUIRED IN ADDITION TO FLOOR DRAINS IF THE DEGREE OF ROUGHNESS OF THE SLIP <br />RESISTANT AGENT IS DEEMED EXCESSIVE UPON EVALUATION BY THIS DIVISION. FLOORING UNDER EQUIPMENT <br />AND ON THE COVED BASES SHALL BE COMPLETELY SMOOTH. FLOOR SURFACES WHICH CONTAIN SLIP <br />RESISTANT AGENTS SHALL BE RESTRICTED TO TRAFFIC AREAS ONLY. <br />2.WALLS AND CEILINGS: <br />a. WALLS OF ALL ROOMS (EXCEPT BAR AREAS, ROOMS WHERE FOOD IS STORED IN UNOPENED CONTAINERS AND <br />DINING AREAS) SHALL BE DURABLE, SMOOTH, NONABSORBENT AND WASHABLE FRP (FIBERGLASS REINFORCING <br />PANELING) WITH STAINLESS STEEL AT SIDES AND REAR OF EXHAUST HOOD. CEILINGS IN FOOD PREPARATION, <br />UTENSIL WASHING AREAS SHALL BE LIGHT COLORED EPOXY OF SEMI-GLOOS WASHABLE PAINT. FOR THE <br />PURPOSES OF THIS REQUIREMENT LIGHT COLORED SHALL MEAN HAVING A LIGHT REFLECTANCE OF 70% OR <br />GREATER. (CURFFL 114155). EXPOSED BRICK, CONCRETE BLOCK, ROUGH PLASTER OR TEXTURED GYPSUM <br />BOARD IS NOT ACCEPTABLE. ACOUSTICAL CEILING TILE MAY BE USED IF IT MEETS THE REQUIREMENTS OF <br />SECTION 114155. A SAMPLE MAY BE REQUIRED FOR REVIEW. <br />b.WALL AND CEILING SURFACE REQUIREMENTS IN AREAS SUCH AS DINING, SALES, EXHIBITION FOOD HANDLING <br />AND CUSTOMER AREAS ARE LESS STRINGENT. ALTERNATIVE FINISH COLORS WILL BE EVALUATED ON A <br />CASE-BY-CASE BASIS. <br />c. THE WALL BEHIND SINKS AND DISHTOWELS SHOULD BE COVERED WITH DURABLE WATERPROOF FRP MATERIAL, <br />(CURFFL 114155) EXTENDING FROM THE TOP OF THE COVED BASE TO AT LEAST TWELVE (12) INCHES ABOVE <br />THE BACKSPLASH. <br />d. WALLS ADJACENT TO FLOOR MOUNTED MOP SINKS SHOULD BE COVERED WITH DURABLE WATERPROOF FRP <br />MATERIAL (CURFFL 114155) EXTENDING FROM THE TOP OF THE SINK TO AT LEAST 48 INCHES ABOVE THE <br />FLOOR <br />e. BEHIND THE COOK LINE AND TO ANY SIDE WALLS THAT ARE ADJACENT OR IN CLOSE PROXIMITY PROVIDE A <br />DURABLE, CLEAN, NONCORRODIBLE AND NONFLAMMABLE STAINLESS STEEL MATERIAL. (CURFFL 114155). <br />3.CONDUITS: <br />a. ALL PLUMBING, ELECTRICAL AND GAS LINES SHALL BE CONCEALED WITHIN THE BUILDING STRUCTURE TO AS <br />GREAT AN EXTENT AS POSSIBLE. WHEN OTHERWISE INSTALLED, THEY SHALL BE MOUNTED OR ENCLOSED SO <br />AS TO FACILITATE CLEANING (E.G., AT LEAST 1/2" INCH FROM THE WALL AND SIX (6) INCHES ABOVE THE FLOOR). <br />(CURFFL 114155). <br />b. WHERE CONDUITS OR PIPELINES ENTER A WALL, CEILING OR FLOOR, THE OPENING AROUND THE LINE SHALL BE <br />TIGHTLY SEALED AND MADE SMOOTH. (CURFFL 114155). <br />c. CONDUITS OR PIPELINES SHALL NOT BE INSTALLED ACROSS ANY AISLE, TRAFFIC AREA OR DOOR OPENING. <br />(CURFFL 114155). <br />d. MULTIPLE RUNS OR CLUSTERS OR PIPELINE SHALL BE INSTALLED WITHIN THE WALLS OR ENCASED IN AN <br />APPROVED SEALED ENCLOSURE. (CURFFL 114155). <br />4.WINDOWS: <br />a.PACKAGED FOOD/UTENSILS DIRECTLY TO OR BY THE CUSTOMER: (REFER TO "CCDEH BUFFET/SERVICE <br />GUIDELINES"). <br />b. DISPLAYS OF UNPACKAGED FOODS OR UTENSILS SHALL BE SHIELDED SO AS TO INTERCEPT A DIRECT LINE <br />BETWEEN THE CUSTOMER'S MOUTH AND THE OR UTENSILS BEING DISPLAYED OR SHALL BE DISPENSED FROM <br />APPROVED SELF-SERVICE CONTAINERS. (CURFFL 114080(b)). <br />c. CAFETERIA, BUFFET AND SALAD BAR SELF-SERVICE, FOOD PREPARATION EQUIPMENT AND FOOD PREPARATION <br />AREAS ETC., SHALL BE PROTECTED BY APPROVED SNEEZEGUARDS. (CURFFL 114080(b)(2)(A)). <br />d. APPROVED SELF-SERVICE CONTAINERS SHALL HAVE TIGHT-FITTING, INDIVIDUAL COVERS. (CURFFL <br />114080(b)(2)(A)). <br />5. DRY FOOD STORAGE: <br />a. ADEQUATE AND SUITABLE SPACE SHALL BE PROVIDED AND DESIGNATED ON PLANS FOR DRY STORAGE <br />PURPOSES. THIS AREA SHALL BE EQUIPPED WITH SUFFICIENT AND APPROVED SHELVING TO ACCOMMODATE <br />THE ANTICIPATED NEEDS. IT SHALL INCLUDE ONLY AISLE SPACE AND FLOOR AREA WHERE SHELVING, CABINETS <br />OR OTHER STORAGE FACILITIES ARE LOCATED. IT SHALL NOT INCLUDE FLOOR AREA WHERE DESKS, <br />EQUIPMENT, LADDERS OR OTHER ITEMS MAY BE PLACED. (CURFFL 114080(a)). <br />b. SHELVING SHALL MEET OR BE EQUIVALENT TO APPROVED APPLICABLE SANITATION STANDARDS WHICH IS <br />SMOOTH, DURABLE, EASILY CLEANABLE, NONABSORBENT AND VERMIN TIGHT. THE LOWEST SHELF SHALL BE AT <br />LEAST SIX (6) INCHES ABOVE THE FLOOR WITH CLEAR UNOBSTRUCTED AREA BELOW. (CURFFL 114065, 114080(a) <br />& 114090(g)). UNFINISHED WOOD IS NOT ACCEPTABLE. <br />5.OTHER REQUIRED STORAGE FACILITIES: <br />a. ADEQUATE AND SUITABLE SPACE SHALL BE PROVIDED FOR SEPARATE STORAGE OF CLEAN AND SOILED LINENS. <br />(CURFFL 114160). <br />b. A ROOM, AREA OR CABINET SEPARATED FROM ANY FOOD PREPARATION OR STORAGE AREA, UTENSIL WASHING <br />OR STORAGE AREA, SHALL BE PROVIDED FOR THE STORAGE OF ALL CLEANING EQUIPMENT, SUPPLIES AND <br />POISONOUS SUBSTANCES (E.G. MOPS, BUCKETS, BROOMS, CLEANING COMPOUNDS, WAXES, INSECTICIDES, <br />RODENTICIDES AND OTHER PESTICIDES, DETERGENTS, BLEACHES, CLEANING COMPOUNDS OR ANY OTHER <br />INJURIOUS OR POISONOUS MATERIALS). (CURFFL 114025 & 114165(a)). <br />6.REFUSE DISPOSAL FACILITIES: <br />a.GARBAGE AND WASTE GREASE SHALL BE DISPOSED INTO ADEQUATE, WATERTIGHT, NONABSORBENT, RODENT <br />PROOF CONTAINERS WITH CLOSE-FITTING LIDS. THERE SHALL BE AN AREA APPROVED FOR THE STORAGE OF <br />THESE CONTAINERS AND FACILITIES FOR THEIR WASHING. (CURFFL 114035, 114040 & 114050). <br />b. STRUCTURAL REQUIREMENTS FOR INTERIOR REFUSE DISPOSAL ROOMS AND AREAS: NOT USED <br />c. STRUCTURAL REQUIREMENTS FOR EXTERIOR REFUSE DISPOSAL FACILITIES: <br />1. A SECURABLE ENCLOSURE IS RECOMMENDED. <br />2. GROUND SURFACES AND ENCLOSURE SURFACES SHOULD BE CONSTRUCTED SO AS TO BE DURABLE AND <br />CLEANABLE (CURFFL 114100). <br />3. WHERE WASHDOWN FACILITIES ARE PROVIDED, LIQUID WASTE SHALL BE DISPOSED OF IN AN APPROVED <br />MANNER. (CURFFL 114100). <br />7.TOILET FACILITIES: <br />a. IN EACH FOOD ESTABLISHMENT, THERE SHALL BE EMPLOYEE TOILET FACILITIES. THE REQUIREMENTS ON THE <br />NUMBER OF TOILETS AND HANDICAPPED FACILITIES SHALL BE IN ACCORDANCE WITH LOCAL BUILDING AND <br />PLUMBING ORDINANCES. (CURFFL 114105 & 114110). <br />b. TOILET FACILITIES WHICH ARE PROVIDED FOR USE BY PATRONS SHALL BE SO SITUATED THAT PATRONS DO NOT <br />PASS THROUGH FOOD PREPARATION, FOOD STORAGE OR UTENSIL WASHING AREAS. (CURFFL 114105). <br />c. THE FLOORS, WALLS AND CEILINGS SHALL HAVE SURFACES THAT ARE SMOOTH, NONABSORBENT AND EASILY <br />CLEANABLE. (CURFFL 114150(a) & 114155). <br />d. HANDWASHING FACILITIES SHALL BE PROVIDED WITHIN OR ADJACENT TO TOILET ROOMS AND SHALL BE <br />EQUIPPED WITH AN ADEQUATE SUPPLY OF HOT AND COLD RUNNING WATER UNDER PRESSURE FROM A <br />PREMIXING FAUCET. HANDWASHING CLEANSER AND SINGLE USE SANITARY TOWELS IN PERMANENTLY <br />INSTALLED DISPENSERS BLOWERS PROVIDED HANDWASHING FACILITIES. <br />PREMIXING FAUCET.HANDWASHING CLEANSER AND SINGLE USE SANITARY TOWELS PERMANENTLY <br />INSTALLED DISPENSERS OR HOT AIR BLOWERS SHALL BE PROVIDED AT HANDWASHING FACILITIES. (CURFFL <br />114115 & 114120). <br />e. TOILET TISSUE SHALL BE PROVIDED IN A PERMANENTLY INSTALLED DISPENSER AT EACH TOILET. (CURFFL <br />114105). <br />f. TOILET ROOMS SHALL BE SEPARATED FROM OTHER PORTIONS OF THE FOOD ESTABLISHMENT BY WELL-FITTED, <br />SELF-CLOSING DOORS THAT PREVENT THE PASSAGE OF FLIES, DUST OR ODORS. (CURFFL 114105). <br />g. PUBLIC TOILET FACILITIES SHALL BE PROVIDED IN EACH ESTABLISHMENT WITH MORE THAN 20,000 SQUARE FEET <br />OF FLOOR SPACE. SEPARATE MEN'S AN WOMEN'S TOILET FACILITIES ARE REQUIRED. (CURFFL 114120). <br />h. TOILET ROOMS SHALL BE VENTILATED TO THE OUTSIDE AIR BY MEANS OF AN OPENABLE SCREENED WINDOW, <br />AND AIR. SHAFT OR A LIGHT SWITCH-ACTIVATED EXHAUST FAN, CONSISTENT WITH THE REQUIREMENTS OF <br />LOCAL BUILDING CODES. (CURFFL 114140). <br />8.CLOTHING CHANGE ROOMS AND AREAS: <br />a. A ROOM, ENCLOSURE (E.G. LOCKER, CABINET, ETC.) OR DESIGNATED AREA SHALL BE PROVIDED WHERE <br />EMPLOYEES MAY CHANGE AND STORE CLOTHING AND PERSONAL EFFECTS. (CURFFL 114135). <br />b. THE ROOM, ENCLOSURE OR DESIGNATED AREA SHOULD BE SIZED TO ACCOMMODATE THE NUMBER OF <br />EMPLOYEES. (CURFFL 114135). <br />c. THE ROOM, ENCLOSURE OR DESIGNATED AREA SHALL BE SEPARATED FROM TOILETS, FOOD STORAGE, FOOD <br />PREPARATION AND UTENSIL WASHING AREAS. (CURFFL 114135). <br />9.EXTERIOR DOORS AND WINDOWS: <br />a. ALL EXTERIOR DOORS SHALL BE WELL-FITTED AND SELF-CLOSING TO EFFECTIVELY PREVENT THE ENTRANCE <br />OF FLIES, RODENTS AND VERMIN. (CURFFL 114030). <br />b. ALL EXTERIOR WINDOWS WHICH TO FOOD PREPARATION AREAS, FOOD STORAGE AREAS AND UTENSIL <br />WASHING AREAS SHALL BE SCREENED TO PREVENT THE ENTRANCE OF VERMIN, ETC. (CURFFL 114030) WITH NO <br />LESS THAN SIXTEEN (16) MESH PER SQUARE INCH SCREENS. <br />10.PASS-THROUGH WINDOWS: NOT USED <br />11.DELIVERY AND CARGO DOORS: NOT USED. <br />12.LIGHTING: <br />a. IN EVERY ROOM AND AREA IN WHICH ANY FOOD IS PREPARED, MANUFACTURED, PROCESSED OR PACKAGED, <br />OR IN WHICH UTENSILS ARE CLEANED, SUFFICIENT NATURAL OR ARTIFICIAL LIGHTING SHALL BE PROVIDED TO <br />PRODUCE AND INTENSITY OF NOT LESS THAT 215 LUX (2O FOOT-CANDLES) AS MEASURED 76 CENTIMETERS (30 <br />INCHES) ABOVE THE FLOOR. (CURFFL 114170). <br />b. THE WORKING SURFACES ON WHICH ALCOHOLIC BEVERAGES ARE PREPARED OR WHERE UTENSILS USED IN <br />THE PREPARATION OR SERVICE OF ALCOHOLIC BEVERAGES ARE CLEANED SHALL BE PROVIDED WITH AT LEST <br />108 LUX (10 FOOT-CANDLES) OF LIGHT. (CURFFL 1141790). <br />c. FOOD AND UTENSIL STORAGE ROOMS, REFRIGERATION STORAGE, TOILET ROOMS AND DRESSING ROOMS <br />SHALL BE PROVIDED WITH AT LEAST 108 LUX (10 FOOT-CANDLES) OF LIGHT. (CURFFL 114170). <br />d. LIGHT FIXTURES IN AREAS WHERE FOOD IS PREPARED, OPEN FOOD IS STORED OR UTENSILS ARE CLEANED <br />SHALL BE OF SHATTERPROOF CONSTRUCTION OR PROTECTED WITH SHATTERPROOF SHIELDS AND BE READILY <br />CLEANABLE. (CURFFL 114170). <br />e. DURING GENERAL CLEANUP ACTIVITIES, AT LEAST 215 LUX (20 FOOT-CANDLES) OF LIGHT MEASURED 76 <br />CENTIMETERS (30 INCHES) ABOVE THE FLOOR, SHALL BE PROVIDED IN THE AREA BEING CLEANED, INCLUDING, <br />BUT NOT LIMITED TO, AREAS WHERE ALCOHOLIC BEVERAGES ARE PREPARED OR SERVED. (CURFFL 114170). <br />13.WATER: <br />a. AN ADEQUATE, PROTECTED, PRESSURIZED, POTABLE SUPPLY OF HOT WATER AT LEAST 49 DEGREES CELSIUS <br />(120 DEGREES FAHRENHEIT) AND COLD WATER SHALL BE PROVIDED. (CURFFL 114095). <br />b. IN SIZING THE WATER HEATER, THE PEAK HOURLY DEMANDS FOR AL SINKS, DISHWASHING MACHINES, ETC., ARE <br />ADDED TOGETHER TO DETERMINE THE MINIMUM REQUIRED RECOVERY RATE. (CURFFL 114095) (REFER TO <br />"CCCDEH WATER HEATER SIZING GUIDELINES"). <br />c. THE WATER SUPPLY SHALL BE FROM A WATER SYSTEM APPROVED BY THE HEALTH OFFICER OR THE STATE <br />HEALTH DEPARTMENT. (CURFFL 114095). <br />14.BACKFLOW PREVENTION: <br />a. AN APPROVED BACKFLOW PREVENTION DEVICE SHALL BE PROPERLY INSTALLED UPSTREAM OF ANY POTENTIAL <br />HAZARD BETWEEN THE POTABLE WATER SYSTEM AND A SOURCE OF CONTAMINATION (E.G., ALL THREADED <br />WATER OUTLETS, MOP SINKS, SPRAYERS, DISHWASHERS, ETC.). (CURFFL 114095). (REFER TO LATEST <br />CALIFORNIA PLUMBING CODE). <br />15.INDIRECT WASTE RECEPTORS: <br />a. ALL STEAM TABLES, ICE MACHINES AND BINS, FOOD PREPARATION SINKS, UTENSIL WASHING SINKS, AND OTHER <br />SIMILAR EQUIPMENT WITH DRAINLINES SHALL DISCHARGE THEIR LIQUID WASTE THROUGH AN AIR GAP INTO A <br />FLOOR SINK OR OTHER APPROVED WASTE RECEPTORS. CONDENSATE AND LIQUID WASTE FROM FOOD <br />PREPARATION EQUIPMENT AND SINKS, UTENSIL SINKS,DISHWASHERS, DIPPER WELLS, STEAM TABLES, ICE <br />MACHINES, BEVERAGE DISPENSERS, REFRIGERATION CONDENSERS AND SIMILAR EQUIPMENT MUST BE <br />DRAINED BY INDIRECT DRAINAGE INTO AN OPEN FLOOR SINK OR OTHER APPROVED WASTE RECEPTOR. <br />UTENSIL WASHING SINKS MAY BE DIRECTLY PLUMBED TO THE SEWER IN IF REQUIRED BY LOCAL BUILDING <br />OFFICIALS. (CURFFL 114100) <br />b. THE FLOOR SINK OR OTHER APPROVED WASTE RECEPTORS SHOULD BE LOCATED TO PROVIDE ADEQUATE <br />DRAINAGE OF THE EQUIPMENT BEING SERVED. (CURFFL 114100). EQUIPMENT SHOULD BE LOCATED WITHIN <br />FIFTEEN (15) FEET. (CALIFORNIA PLUMBING CODE 803). <br />c. FLOOR SINKS OR OTHER APPROVED WASTE RECEPTORS SHALL BE LOCATED SO THAT THEY ARE READILY <br />ACCESSIBLE FOR INSPECTION, CLEANING AND REPAIR. (CURFFL 114100). OVERFLOW FROM FLOOR SINKS SHALL <br />BE PREVENTED FROM FLOWING INTO INACCESSIBLE AREAS (E.G., STORAGE CABINET, DISPLAY <br />REFRIGERATORS, ETC.). <br />d. IN GENERAL, FLOOR SINKS SHOULD BE INSTALLED FLUSH WITH THE FLOOR TO PREVENT TRIPPING HAZARDS <br />AND PREVENT HARBORAGE OF DIRT AND DEBRIS, HOWEVER SOME JURISDICTIONS MAY REQUIRE FLOOR SINKS <br />ABOVE GRADE. CHECK WITH LOCAL BUILDING AND SAFETY OFFICIALS. <br />16. SEWAGE DISPOSAL, GREASE TRAPS AND INTERCEPTORS: <br />a. ALL LIQUID WASTE, INCLUDING SEWAGE GENERATED BY A FOOD ESTABLISHMENT, SHALL BE DISPOSED OF IN AN <br />APPROVED MANNER INTO EITHER A PUBLIC SEWER SYSTEM OR TO AN APPROVED ON-SITE SEWAGE DISPOSAL <br />SYSTEM. (CURFFL 114100). CHECK WITH LOCAL HEALTH, SANITARY OR PUBLIC WORKS AGENCIES FOR <br />INFORMATION OR REGULATIONS REGARDING SPECIAL SEWERAGE, GREASE TRAP AND GREASE INTERCEPTOR <br />REQUIREMENTS. IN GENERAL GREASE TRAPS SHOULD BE INSTALLED FLUSH WITH THE FLOOR TO PREVENT <br />SANITATION PROBLEMS, CHECK WITH LOCAL BUILDING AND SAFETY OFFICIALS FOR REQUIREMENTS. <br />17. VENTILATION: <br />a. PROVIDE ADEQUATE VENTILATION TO REMOVE GASES, ODORS, STEAM, HEAT, GREASE, VAPORS AND SMOKE <br />FROM ALL ROOMS IN THE FACILITY INCLUDING: FOOD PREPARATION, SCULLERY, TOILET, JANITORIAL, GARBAGE <br />AND CHANGE ROOMS, CONSISTENT WITH THE REQUIREMENTS OF LOCAL BUILDING CODES. (CURFFL 114140). <br />18.EXHAUST HOODS AND DUCTS: <br />a. MECHANICAL EXHAUST VENTILATION SHALL BE REQUIRED AT OR ABOVE ALL COMMERCIAL TYPE DEEP FAT <br />FRYERS, BROILERS, FRY GRILLS, STEAM JACKETED KETTLES, RANGES, OVENS BARBECUES, ROTISSERIES, <br />DISHWASHING MACHINES AND SIMILAR EQUIPMENT TO EFFECTIVELY REMOVE GASES, ODORS, STEAM, HEAT, <br />GREASE VAPORS AND SMOKE FROM THE FOOD ESTABLISHMENT. USUALLY CHEMICAL SANITIZING OR <br />UNDERCOUNTER DISHWASHING MACHINES DO NOT REQUIRE EXHAUST HOODS. (CURFFL 114140). <br />b. ALL HOODS, DUCTS, AND EXHAUST OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT EDITION <br />OF THE UNIFORM MECHANICAL CODE AS ADOPTED BY THE LOCAL BUILDING DEPARTMENT. VENTILATION PLANS <br />FOR EACH SYSTEM SHALL INCLUDE FRONT AND SIDE ELEVATIONS OF THE EXHAUST HOOD AND DUCT DETAILS <br />TO THE ROOF FANS (BOTH EXHAUST AND MAKE-UP AIR). <br />c. PROVIDE MANUFACTURER SPECIFICATION SHEETS FOR EXHAUST FAN, MAKE-UP AIR DIFFUSER. <br />d.ALL JOINTS AND SEAMS SHALL BE TIGHT OR SOLDERED FOR EASE OF CLEANING. RIVETED SEAMS ARE NOT <br />ACCEPTABLE. <br />e.FOOD HEATING OR WARMING DEVICES, CHEESE MELTERS, ETC. THAT ARE INSTALLED ABOVE OTHER <br />EQUIPMENT BENEATH AND EXHAUST HOOD MAY CREATE AN AIR FLOW OBSTRUCTION TO PROPER VENTILATION <br />EQUIPMENT VENTILATION DESIGNED.DESIGN,CONSTRUCTION <br />OF THE EQUIPMENT FOR WHICH THE HOOD VENTILATION IS DESIGNED. THE DESIGN, CONSTRUCTION AND <br />INSTALLATION OF SUCH WARMING DEVICES UNDER A HOOD ARE SUBJECT TO EVALUATION AND APPROVAL BY <br />THIS AGENCY PRIOR TO INSTALLATION. <br />f.CANOPY TYPE HOODS: THE LOWER LIP OF CANOPY-TYPE HOODS SHALL NOT BE MORE THAN SEVEN (7) FEET <br />ABOVE THE FLOOR AND SHALL NOT BE MORE THAT FOUR (4) FEET ABOVE THE COOKING SURFACE. THE HOOD <br />SHALL OVERHANG OR EXTEND A HORIZONTAL DISTANCE NOT LESS THAN SIX (6) INCHES BEYOND THE OUTER <br />EDGES OF THE COOKING SURFACES, OPEN ON ALL SIDES. IT SHALL HAVE GREASE TROUGHS AND DRIP PANS <br />THAT ARE EASILY CLEANABLE. <br />g.NONCANOPY-TYPE HOODS: NON-CANOPY TYPE HOODS WILL BE APPROVED PROVIDING THEY ARE <br />CONSTRUCTED TO BE EASILY CLEANABLE AND THEY COMPLY WITH MINIMUM EXHAUST AIR VELOCITY <br />REQUIREMENTS. SHIELDING AT THE ENDS OF THE HOOD MAY BE NECESSARY TO PREVENT INTERFERENCE <br />FROM CROSS DRAFTS. <br />h.MAKE-UP AIR: MAKE-UP AIR SHALL BE PROVIDED AT LEAST EQUAL TO THAT AMOUNT WHICH IS MECHANICALLY <br />EXHAUSTED. WINDOWS AND DOORS SHALL NOT BE USED FOR THE PURPOSE OF PROVIDING MAKE-UP AIR. <br />i.FIRE EXTINGUISHING SYSTEM: FIRE EXTINGUISHING SYSTEMS MAYBE REQUIRED BY THE LOCAL FIRE <br />DEPARTMENT CODES. THEY SHALL BE INSTALLED SO AS TO ALLOW EASY CLEAN ABILITY OF THE HOOD AND <br />DUCT SYSTEMS, AND WHENEVER POSSIBLE, SHALL NOT BE INSTALLED ABOVE FOOD OR UTENSIL HANDLING <br />AREAS. <br />j. A BALANCE REPORT COMPLETED BY A THIRD PARTY MAY BE REQUIRED PRIOR TO FINAL CLEARANCE. <br />19.EQUIPMENT REQUIREMENTS: <br />a. ALL NEW AND REPLACEMENT EQUIPMENT SHALL MEET OR BE EQUIVALENT TO APPLICABLE SANITATION <br />STANDARDS. EQUIPMENT DESIGN, CONSTRUCTION AND INSTALLATION ARE SUBJECT TO APPROVAL BY THE <br />ENFORCEMENT OFFICER. (CURFFL 113730). <br />b. ALL UTENSILS, DISPLAY CASES, WINDOWS, COUNTERS, SHELVES, TABLES, REFRIGERATION UNITS, SINKS, <br />DISHWASHING MACHINES AND OTHER EQUIPMENT OR UTENSILS USED IN THE PREPARATION, SALE, SERVICE <br />AND DISPLAY OF FOOD SHALL BE NONTOXIC, NONCORRODIBLE MATERIALS AND SHALL BE CONSTRUCTED, <br />INSTALLED AND MAINTAINED TO BE EASILY CLEANED. (CURFFL 1114090(g)). <br />c. EQUIPMENT SHALL BE INSTALLED SO AS TO FACILITATE CLEANING UNDER AND AROUND THE EQUIPMENT, AND <br />OF ALL THE ADJACENT SURFACES. (CURFFL 114090(g)). EQUIPMENT SHOULD BE SEALED TO ADJACENT WALLS <br />AND EQUIPMENT, OR SHOULD BE SPACED AWAY FROM THE ADJACENT WALLS AND EQUIPMENT AT LEAST SIX (6) <br />INCHES FOR EVERY FOUR (4) LINEAR FEET OF EQUIPMENT. <br />d. ALL FLOOR MOUNTED EQUIPMENT SHALL BE PLACE ON CASTERS WHICH MEET OR ARE EQUIVALENT TO <br />APPLICABLE SANITATION STANDARDS, MINIMUM SIX (6) INCH HIGH EASILY CLEANABLE LEGS OR BE COMPLETELY <br />SEALED IN POSITION ON AT LEAST FOUR (4) INCH HIGH CONTINUOUSLY COVED BASE OR CONCRETE CURB. <br />(CURFFL 113730 & 114090(g)) (NSF STANDARD 2). <br />20.REFRIGERATION: <br />a. ALL REACH-IN AND WALK-IN REFRIGERATION AND FREEZER UNITS SHALL BE ADEQUATE IN CAPACITY AND <br />USAGE TO MEET THE NEEDS OF THE PROPOSED OPERATION AND SHALL: (CURFFL 113860, 114080(a) & 113995) <br />(NSF STANDARD 7): <br />(1) BE SPECIFICALLY CONSTRUCTED FOR COMMERCIAL USE AND SHALL MEET OR BE EQUIVALENT TO <br />APPLICABLE SANITATION STANDARDS. DOMESTIC MODEL REFRIGERATORS (CRFFL 114065). <br />(2) HAVE SHELVING THAT IS NONABSORBENT, NONCORRODIBLE, EASILY CLEANABLE WHICH MEETS OR IS <br />EQUIVALENT TO APPROVED APPLICABLE SANITATION STANDARDS. (CURFFL 114090(d)). <br />(3) BE PROVIDED WITH AN ACCURATE, READILY VISIBLE THERMOMETER. (CURFFL 113995(d)). <br />(4) DRAIN CONDENSATE AND OTHER LIQUID WASTE IN A SANITARY MANNER TO A FLOOR SINK OR OTHER <br />APPROVED RECEPTOR THAT IS PROPERLY CONNECTED TO THE DRAINAGE SYSTEM. CONDENSATE FROM <br />REACH-IN REFRIGERATORS AND FREEZERS MAY BE DRAINED TO A PROPERLY INSTALLED AND FUNCTIONING <br />EVAPORATOR. (CURFFL 27625)(CALIFORNIA PLUMBING CODE 801.2.3). <br />(5) OPEN INTO AN APPROVED AREA OF THE FOOD FACILITY. (CURFFL 113730 & 114145). <br />(6)COOLING COILS AND RELATED ELECTRICAL, DRAINAGE AND REFRIGERANT LINES SHALL BE INSTALLED INA <br />SAFE AND EASILY CLEANABLE MANNER. DRAINAGE AND REFRIGERANT LINES SHALL BE CONSTRUCTED OF <br />NONTOXIC MATEIALS OR PROPERLY INSULATED AND COVERED WITHAN APPROVED, EASILIY CLEANABLE AND <br />NONTOXIC MATERIAL. <br />b. WALK-IN REFRIGERATION AND STORAGE FREEZER UNITS: NOT USED. <br />21.SINKS: <br />HOT AND COLD WATER UNDER PRESSURE SHALL BE PROVIDED THROUGH A MIXING VALVE TO EACH <br />COMPARTMENT OR THE FOLLOWING SINKS: <br />a. KITCHEN UTENSIL SINKS: <br />(1)WHERE MULTISERVICE KITCHEN UTENSILS (I.E. POTS, PANS, ETC.) ARE USED, A MINIMUM THREE (3) <br />COMPARTMENT STAINLESS STEEL SINK WITH DUAL INTEGRAL STAINLESS STEEL DRAINBOARDS SHALL BE <br />PROVIDED. (CURFFL 114090(b)). THIS SINK MUST HAVE AN INDIRECT CONNECTION TO A FLOOR SINK. <br />(2) THE SINK MUST BE CAPABLE OF ACCOMMODATING THE LARGEST UTENSIL TO BE WASHED AND THE <br />DRAINBOARDS SHALL BE AS LARGE AS THE LARGEST SINK COMPARTMENT. (CURFFL 114090(b)). A <br />COMPARTMENT SIZE OF APPROXIMATELY 18 X 18 X 12 INCHES DEEP WILL GENERALLY BE ADEQUATE FOR <br />MOST UTENSILS. <br />(3)A THREE COMPARTMENT SINK MAY BE REQUIRED WITHIN EACH SEPARATE SECTION OF A LARGE FOOD <br />ESTABLISHMENT WHICH HANDLES UNPACKAGED FOODS (I.E., DELI, MEAT, BAKERY, SUSHI BARS, OYSTER <br />BARS, ETC.). (CURFFL 114090(b)). <br />(4)WHEN A SINK IS INSTALLED NEXT TO A WALL, A STAINLESS STEEL "BACKSPLASH" SETENDING UP THE WALL <br />AT LEAST 8 INCHES SHALL BE FORMED AS INTEGRAL PART OF THE SINK, AND SEALDED TOT HE WALL. THE <br />ENDS OF THE SINK MUST BE INSTALLED WITH A MINIMUM TWO (2) INCH SEPARATION FROM THE WALLS OR BE <br />EQUIPPED WITH INTEGRALLY INSTALLED "END RETURNS". <br />(5)ADDITIONAL DRAINBOARD SPACE OR STORAGE RACKS MAY BE REQUIRED WHERE MULTI-SERVICE <br />CUSTOMER EATING AND DRINKING UTENSILS ARE USED. <br />b. EATING AND DRINKING UTENSIL SINKS: <br /> (1) SEE A(1) ABOVE. DISHWASHING MACHINES AR RECOMMENDED WHERE A LARGE VOLUME OF EATING AND <br />DRINKING UTENSILS ARE WASHED. (CURFFL 114090(c)(I)). <br /> (2) THE SINK MUST BE CAPABLE OF ACCOMMODATING THE LARGEST UTENSIL TO BE WASHED AND THE <br />DRAINBOARDS SHALL BE AS LARGE AS THE LARGEST SINK COMPARTMENT (CURFFL 114090(b)). A <br />COMPARTMENT SIZE OF 18 X 18 X 12 INCHES DEEP WITH A DRAIN BOARD (10" X 18") MAY REQUIRE A QUICK <br />FUNNEL DRAIN OR A FOURTH (4TH) SINK COMPARTMENT FOR DISPOSAL OF DRINK/ICE WASTE. (CURFFL <br />114090(a)). <br />(3) WHERE ALCHOLIC BEVERAGES ARE SERVED, THE FACILITY MUST PROVIDE AND APPROVED THREE (3) <br />COMPARTMENT BAR SINK WITH MINIMUM 10"X14"X10" DEEP COMPARTMENTS WITH 18" LONG DUAL, <br />INTEGRALLY INSTALLED STAINLESS STEEL DRAINBOARDS AND "BACKSPLASH". THIS SINK MUST HAVE AD <br />INDIRECT CONNECTION TO A FLOOR SINK. A BAR SINK EQUIPPED WITH A FOURTH DUMPING COMPARTMENT <br />IS STRONGLY RECOMMENDED. <br />c. FOOD PREPARATION SINKS: FOOD FACILITIES NEEDING A SEPARATE SINK FOR FOOD PREPARATION SUCH AS, <br />BUT NOT LIMITED TO, THAWING, WASHING, OR SOAKING SHALL HAVE A FOOD PREPARATION AREA (I.E., DELI, <br />MEAT, BAKERY, SUSHI BAR, OYSTER BAR, ETC.). (CURFFL 114100 & 114085 - THAWING). (SEE LATEST EDITION OF <br />CALIFORNIA PLUMBING CODE). TISSINK MUST HAVE AN INDIRECT CONNECTION TO A FLOOR SINK. <br />d. HANDWASHING SINKS: <br />(1) HANDWASHING SINKS SHALL BE PROVIDED IN EACH FOOD PREPARATION AREA (I.E., DELI, MEAT, BAKERY, <br />SUSHI BAR, OYSTER BAR, ETC.). (CURFFL 114115). <br />(2) SOAP AND SINGLE-USE TOWELS SHALL BE PROVIDED IN PERMANENTLY INSTALLED DISPENSERS AT THE <br />HANDWASHING SINKS. (CURFFL 114115). <br />(3) HAND-WASHING SINKS SHALL HAVE SUCH WATER PROVIDED FROM A COMBINATION FAUCET, OR WATER <br />FROM A PREMIXING FAUCET WHICH SUPPLIES WARM WATER FOR A MINIMUM OF TEN (10) SECONDS WHILE <br />BOTH HANDS ARE FREE FOR WASHING. (CURFFL 1141115). <br />e. JANITORIAL SINK: <br />(1) FOOD ESTABLISHMENTS SHALL BE EQUIPPED WITH AT LEAST ONE (1) OF THE FOLLOWING TWO USED <br />EXCLUSIVELY FOR GENERAL CLEANING PURPOSES AND FOR THE DISPOSAL OF MOP BUCKET WASTE OR <br />OTHER LIQUID WASTE: (CURFFL 114165(b)) - A ONE (1) COMPARTMENT, NON-POROUS JANITORIAL SINK <br />(CURFFL 114165(b)(1)) OR A SLAB, BASIN OR FLOOR CONSTRUCTED OF CONCRETE OR EQUIVALENT MATERIAL, <br />CURBED AND SLOPED TO A DRAIN. (CURFFL 114165(b)(2)). <br />(2) THE SINK SHALL BE LOCATED SO AS NOT TO CONTAMINATE ANY FOOD PREPARATION AREAS, FOOD <br />STORAGE AREAS, UTENSILS OR EQUIPMENT. (CURFFL 114010 & 114090(h)). <br />(3) THE MIXING VALVE FAUCET SHALL BE EQUIPPED WITH A BACKFLOW PREVENTION DEVICE. (CURFFL <br />114165(b)(2)). <br />f. FLOOR SINKS: <br />(1) ALL CONDENSATE AND SIMILAR LIQUID WASTE SHALL BE DRAINED BY MEANS OF INDIRECT WASTE PIPES INTO <br />AND OPEN FLOOR SINK. <br />(2) FLOOR SINKS SHALL BE INSTALLED FLUSH WIN THE FLOOR SURFACE, UNLESS LOCAL BUILDING AUTHORITIES <br />REQUIRE A RAISED FLOOR SINK. <br />(3) HORIZONTAL RUNS OF DRAIN LINES SHALL BE AT LEAST A 1/2" FROM THE WALL AND SIX (6) INCHES OFF THE <br />FLOOR AND SHALL TERMINATE AT LEAST ONE (1) INCH ABOVE THE OVERFLOW RIM OF THE SINK. <br />(4) FLOOR SINKS SHALL BE LOCATED WITHIN 15 FEET OF THE DRAIN OPENING OF HE EQUIPMENT SERVED. <br />(5) WASTE LINES MAY TO CROSS ANY AISLE, TRAFFIC AREA R DOOR OPENING. <br />(6) FLOOR SINKS OF FLOOR DRAINS ARE NOT PERMITTED INSIDE WALK-IN REFRIGERATION UNITS. <br />22. DISHWASHING AND GLASS WASHING MACHINES: <br />a. AN AREA SHOULD BE PROVIDED FOR SCRAPING UTENSILS AND EQUIPMENT AS CIRCUMSTANCES REQUIRE. AN <br />OVERHEAD PRE-RINSE SPRAYER WITH SCUPPER TRAY, SINK OR GARBAGE DISPOSAL WILL SATISFY THIS <br />REQUIREMENT. (CURFFL 114090(a)). <br />b. DISHWASHING MACHINES MAY BE CONNECTED DIRECTLY TO THE SEWER IMMEDIATELY DOWNSTREAM FROM A <br />FLOOR DRAIN OR THEY MAY BE DRAINED THROUGH AN APPROVE CONNECTION. (CURFFL 114100). <br />c. SPRAY TYPE DISHWASHING AND GLASSWASHING MACHINES WHICH ARE DESIGNED FOR A HOT WATER <br />BACTERICIDAL RINSE SHALL BE PROVIDED WITH AN APPROVED BOOSTER HEATER OR BE CONNECTED TO AN <br />APPROVED RECIRCULATING WATER SYSTEM WHICH IS CAPABLE OF MAINTAINING THE RINSE WATER AT NOT <br />LESS THAN 180 DEGREES FAHRENHEIT (82 DEGREES CELSIUS). THESE MACHINES NORMALLY REQUIRE AN <br />APPROVED TYPE II EXHAUST HOOD. (CURFFL114090(c)(2) & 114060). (CALIFORNIA MECHANICAL CODE) (NSF <br />STANDARD 3). <br />d. SPRAY TYPE DISHWASHING AND GLASSWASHING MACHINES WHICH ARE DESIGNED FOR A BACTERICIDAL RINSE <br />SHALL BE CAPABLE OF MAINTAINING THE RINSE WATER AT TEMPERATURE IN ACCORDANCE WITH ITS <br />APPROVED APPLICABLE SANITATION LISTING (NSF STANDARD 3). <br />e. DISHWASHING MACHINES MUST HAVE TWO (2) INTEGRAL STAINLESS STEEL DRAINBOARDS OR DISHTABLES, ONE <br />FOR SOILED UTENSILS AND ONE FOR CLEAN UTENSILS. THE DRAINBOARDS SHALL BE SLOPED AND DRAINED TO <br />AN APPROVED WASTE RECEPTOR. (CURFFL 114090(e)). (DISH TABLES ARE EXTENDED DRAINBOARDS USED FOR <br />THE PURPOSE OF SORTING SOILED OR CLEAN DISHES). <br />f. FOR GLASSWASHING MACHINES AND UNDERCOUNTER DISHWASHING MACHINES, THERE SHALL BE TWO (2) <br />METAL DRAINBOARDS, ONE FOR SOILED UTENSILS AND ONE FOR CLEAN UTENSILS, LOCATE ADJACENT TO THE <br />MACHINE. THE DRAINBOARDS SHALL BE SLOPED AND DRAINED TO AN APPROVED WASTE RECEPTOR. (CURFFL <br />114090(e)). <br />g. DRAINBOARDS OR DISHTABLES SHALL BE LARGE ENOUGH TO ADEQUATELY STORE ALL UTENSILS ABOVE THE <br />FLOOR AT ALL TIMES OR ADDITIONAL APPROVED SHELVING, RACKS OR DISHTABLES SHALL BE PROVIDED IN THE <br />DISHWASHING AREA FOR THIS PURPOSE. (CURFFL 114090(f)(g)(h)). <br />h. A MINIMUM OF A THREE (3) COMPARTMENT STAINLESS STEEL SINK WITH DUAL INTEGRAL METAL DRAINBOARDS <br />IS REQUIRED IN ADDITION TO AMY DISHWASHING MACHINE. (CURFFL 114090(b)). <br />i. WHEN A DISH TABLE IS INSTALLED NEXT TO A WALL, THE INTEGRAL METAL SPLASH SHALL BE SEALED TO THE <br />WALL. (SEE WALLS ABOVE 2b) (CURFFL 114155(b) - SMOOTH). <br />23. DIPPER WELL: <br />a. A COLD RUNNING WATER DIPPER WELL SHALL BE PROVIDED, IF SCOOPS, OR OTHER REUSABLE SERVING <br />UTENSILS ARE STORED IN WATER. THE DIPPER WELL SHALL BE DRAINED BY MEANS OF AN INDIRECT <br />CONNECTION. (CURFFL 114010 & 114100). <br />24. ICE MACHINE: <br />ALL ICE MACHINES SHALL BE LOCATED WITHIN THE BUILDING IN AN EASILY ACLEANABLE, WELL VENTILATED AREA, <br />AND SHALL BE DRAINED TO A FLOOR SINK. <br />25. WINDOW SCREENS: ALL OPENABLE WINDOWS, SUCH AS RESTROOM WINDOWS, SHALL BE SCREENED WITH NOT <br />LESS THAN 16 MESH SCREENING. <br />GENERAL ENVIRONMENTAL HEALTH DEPARTMENT NOTES <br />GENERAL <br />NOTES & <br />HOOD <br />WORKSHEET <br />K0.1CORDES VILLAGE PLAZARAJA SALEEM & SANDYA SALEEM, OWNERSTHuB TEA & CAKESREVISIONS DATE <br />DATEAPPROVAL <br />JOB: <br />DATE: <br />SHEET TITLE: <br />SHEET NO. <br />4/9/2020 <br />ADESNECILRCHITECTCW.NHOJ OWE <br />E <br />,JR. <br />NO. C-9199 <br />F <br />-1.N <br />ER <br />3 1 -2 1O <br />ETATS <br />C A L IF O RNIAJohnWCowee,Jr.MOUNTAIN HOUSE, CAwww.architectural-concepts.net <br />johncowee06@gmail.com <br />ARCHITECTURAL <br />INTERIORS PLANNING <br />509 RAMONA AVE. <br />ALBANY, CA 94706-1431 <br />T/F 510-525-9630 <br />CONCEPTS <br />ARCHITECTURE <br />REVISION 0 <br />STAMP:1140 SOUTH TRADITION STREETSK-MH-C1TENAANT IMPROVEMENTHOOD WORKSHEET COOKING EQUIPMENT <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />CASTERS & QUICK-DISCONNECTS STRONGLY RECOMMENDED. SPECIFIED ? <br />HOOD WIDE ENOUGH TO ALLOW MINIMUM OF 6" FRONT AND BACK OF EQUIPMENT ? <br />HOOD LONG ENOUGH TO ALLOW MINIMUM OF 6" ON SIDES OF EQUIPMENT ? <br />CANOPY LIP GREATER THAN OR EQUAL TO 6'-6" ABOVE THE FLOOR ? <br />CANOPY LIP GREATER THAN OR EQUAL TO 4'-0" ABOVE THE FLOOR ? <br />CANOPY FREE OF HORIZONTAL ELECTRICAL/ ANSUL LINES ? <br />WHAT KIND OF HOOD? TYPE 1 <br />UL LISTED AIR FLOW RATE AT 1,800 CFM/ FT OF CAPTURE LENGTH <br />HOOD OPENING (INSIDE DIMENSIONS) 42" (WIDTH) x 72" (LENGTH) /144 <br /> 21 SQ. FT. x 100 Q FACTOR FROM UMC <br />OTHER FORMULA 72" - 12" = 5'-0" X 300 CFM / L.FT. <br />OTHER FORMULA IS FOR WHAT KIND OF HOOD? U.L. LISTED HOOD <br />= _______ CFM <br />= _______ CFM <br />= _______ CFM <br />HOOD TYPE 1 U.L. LISTED GREASE EXTRACTOR <br />CFM <br />FILTERS <br />DUCT <br />STATIC PRESSURE & EXHAUST FAN <br />CURB FOR EXHAUST FAN / BLOWER <br />MAKE-UP AIR <br />CURB FOR MAKE-UP AIR FAN / BLOWER <br />FILTER MFG.: U.L.. LISTED MODEL# : 1620 <br />FILTER TYPE: ALUMINUM BAFFLE S/S <br />FUNCTIONAL FILTER SIZE: 14.5" (HEIGHT) x 18.75" (LENGTH) <br />FILTER SIZE: 16" (HEIGHT) x 20" (LENGTH) <br />NO OF FILTERS: 3 x 1.88 (USABLE SQ. FT. PER FILTER) <br />MFG'S RATING : 200 FPM TO 600 FPM OR 800 CFM TO 1,200 CFM <br /> 2,100 CFM + 11.28 SQ. FT. (TOTAL FILTER SQ. FT.) <br />BAFFLE FILTER FPM MUST BE 200 - 600 FPM IS IT? <br />HORIZONTAL SLOT FILTER FPM SHOULD = 1000, MUST = 800 - 1200. IS IT? <br />FPM CAN BE < OR > ABOVE IF THIS IS A "LISTED" HOOD IS IT? <br />TOTAL OF FILTER WIDTHS (60") MUST BE < HOOD LENGTH. IS IT? <br />= _______ FUNCTIONAL SQ. FT. PER FILTER <br />= _______ TOTAL FILTER SQ. FT. <br />= _______ TOTAL FILTER AREA <br />= _______ TOTAL FILTER SQ. FT. <br />= _______ FPM <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />DUCT DIMENSIONS: 12" (INCHES) x 12" (INCHES) = 144 SQ. IN. + 144 <br />HOOD GREATER THAN 12 FT. LONG SHOWS > 1 EXHAUST OUTLET TO MAIN DUCT? <br />2,100 CFM / 1.88 SQ. FT. (TOTAL DUCT SQ. FT.) <br />DUCT FPM SHOULD = 1800: MUST BE 1600 - 2500 (TYPE I). IS IT? <br />= _______ SQ. FT. (DUCT AREA) <br />YES NO N/A <br />= _______ FPM <br />YES NO <br />EXHAUST FAN MFG: ACME MODEL# PNU-150 H.P. 5 <br />EXHAUST FAN MOTOR VOLTAGE: 115 RPM 240 <br />TOTAL SP .25 INSPECTOR FROM PLANS & SP CHART = .25 SP <br />NO. OF ELBOWS 2 CLEAN OUT AT EACH ELBOW? <br />UNIT HANDLES GREASE LADEN VAPORS? <br />PULLS CFM AT SP? <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />EXHAUST CURB MFG: VENT TECH MODEL# EXCB <br />EXHAUST CURB SIZE: 28.5(2) HOLE SIZE: PER MFR'S SPEC. WEIGHT: 185 LBS. <br />MAKE-UP AIR MFG: ARCTIC CIRCLE ODEL# ED 460 A H.P. 1/2 HP <br />MAKE-UP AIR SP = .3 IN. INSPECTOR FROM PLANS & SP CHART = .25 IN. SP <br />4,000 CFM (EXHAUST) + 1000 CFM (MAX/ DIFFUSER) = 4 NEXT HIGHER 4 (DIFFUSERS) <br />MAKE-UP AIR UNIT SUPPLIES 95-100% OF EXHAUST CFM AT ESTIMATED SP? <br />MAKE-UP AIR UNIT ON ROOF GREATER THAN OR EQUAL TO 10 FT. FROM EXHAUST? <br />DIFFUSER CENTERS ON CEILING GREATER THAN OR EQUAL TO 5 FT. FROM HOOD? <br />EXHAUST AND MAKE-UP AIR INTERLOCKED? <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />YES NO N/A <br />MAKE-UP CURB MFG: VENT TECH MODEL# ECCB <br />MAKE-UP CURB SIZE: 17-3/4" HOLE SIZE: 16" WEIGHT: 275 <br />TOTAL STATIC PRESSURE BASED ON THE FOLLOWING CONDITIONS AND CALCULATIONS: <br />),/7(5686('+2856:,7+287&/($1,1*ƒ675$,*+7'8&7/(1*7+ 12(/%2:6 <br />DUCT ENTRANCE AND EXIT LOSSES <br />NOTES: <br />1. CONSULT FACTORY FOR RE-ENGINEERING OF STATIC PRESSURE AND EXHAUST SYSTEM IF DUCT VARIATIONS ARE <br />REQUIRED. <br />2. MAKE-UP / SUPPLY AIR BLOWER (MECHANICAL SUPPLY AIR IS REQUIRED FOR BOTH TYPE 1 & TYPE 11 HOODS). <br />X <br />2,100 <br />1,500 <br />3,600 <br />1.88 <br />2.22 <br />11.28 <br />1.00 <br />1,117 <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />187 <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />X <br />5.64