My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085108_SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
18846
>
2600 - Land Use Program
>
SR0085108_SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:52:08 PM
Creation date
4/20/2022 12:11:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0085108
PE
2602
STREET_NUMBER
18846
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
01709051
ENTERED_DATE
4/6/2022 12:00:00 AM
SITE_LOCATION
18846 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3.5 General area septic permit history (number/types/dates of permits, age of system, <br />permit numbers, copies in report): In searching permits for septic systems in San Joaquin <br />County Environmental Health Department records, the septic systems in this general area range <br />in installation dates from 1962 to 2006. (Copies of permits are in index.) <br />3.6 Discussion of general area septic tank repair history: Repair history of the septic systems <br />in this area reveal that the leach lines and seepage pits have resulted in moderate performance. <br />Additional septic tanks, seepage pits, and leach lines were added to the existing septic systems in <br />the past. (See Appendix) <br />3.7 Description of proposed or expected maximum (including second unit dwellings) septic <br />tank usage on site: There are no immediate plans for construction. The sites are three proposed <br />trucking facilities. They will have very few employees and one bathroom per site. Parcel 3 has <br />two metal storage buildings and existing bathrooms with a septic system. No additional additions <br />are proposed. <br />4.0 GROUNDWATER INFORMATION SECTION <br />4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br />ground water in this area is approximately 60 feet according to the map of "Lines of Equal Depth <br />to Groundwater" published Spring, 2021, by the San Joaquin County Flood and Water <br />Conservation District. The gradient descends from east to west. <br />4.2 Description/discussion of any existing and/or potential groundwater contamination <br />issues in the general location of the site: The concerns for groundwater contamination in this <br />area are deemed moderate due to the depths involved. Insecticides, pesticides, and fertilizers <br />typically do not significantly impact groundwater at these depths. This property has not been <br />farmed. <br />4.3 Description of location (address/APN), type and construction of well and location <br />(well head/kitchen tap) where water sample(s) were obtained: Water samples were taken from <br />a spigot on the subject property at 18846 State Route 99 E. Frontage Road on October 8, 2021 by <br />Tristan Hartung of Dillon & Murphy. <br />4.4. Description of constituents being tested for in the water sample: Nitrates and DBCP were <br />tested. <br />4.5 Description of how sample was obtained, handled, stored, and transported to the <br />lab: The water samples were obtained from a spigot at the well located on the subject property <br />at 18846 State Route 99 E. Frontage Road. The samples were taken by Tristan Hartung of <br />Dillon & Murphy, and driven directly to Precision Enviro-Tech. The samples were taken and <br />handled in accordance with Precision Enviro-Tech requirements. The results from the test can <br />be found in the Appendix. <br />4.6 Complete Chain of Custody document, including printed and signed name of third party <br />sampler, condition of sample and date and time the sample was submitted to the lab. For <br />Laboratory samplers, complete laboratory report to include the above noted information: <br />The complete chain of custody document is located in the Appendix. <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.