My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2023 2:40:08 PM
Creation date
7/21/2022 10:35:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Waitinq Times <br /> Waiting times after the delivery of product , after product is circulated through the line or <br /> after pumping has stopped are not necessary before valid tests can be conducted . For <br /> the Hourly testing , 2 tests were run after each circulation . As a result , the waiting times <br /> for the hourly testing ranged from 0 minutes to 24 minutes , with an average of 5 . 5 <br /> minutes . <br /> Table 3 . Performance Parameters for the Pneumercator LLP -203 Series PLLD <br /> for Flexible , Rigid , and Hybrid Pipelines Using the EPA Protocol <br /> Parameter <br /> Value <br /> Probability of Detection (PD) 100 % (87 . 79 % to 100% ) <br /> of a 3 . 0 gal/hr leak (Hourly) <br /> Probability of False Alarm ( Hourly PFA) 0% (0% to 12 . 73% ) <br /> Maximum Line Size Combination of all piping , flexible or rigid <br /> or in combination limited to a total <br /> capacity of 1178 . 68 gal . for hourly <br /> testing <br /> Waiting Time after Delivery of None Required <br /> Product before Conducting a Test <br /> Waiting Time after Product Circulation None Required <br /> Through Line before Conducting a Test <br /> Hourly Test Times with a 3 . 0 gal/hr Leak Range : 7-9 minutes <br /> Hourly Test Times without Leak Range : 13 minutes <br /> 6 . 0 Conclusions <br /> The following conclusions and recommendations are based on the results of the testing <br /> described in this report . <br /> • The observed PQ for a 3 . 0 gal/h leak was 100 % and the PFA on a tight line was <br /> 0 . 0 % . <br /> • Using the EPA protocol , the Pneumercator LLP -203 Series PLLD can be used on <br /> any pipeline for hourly testing up to 1178 . 68 gallons in volume including rigid , <br /> flexible or a combination of pipeline types . <br /> • A waiting time after product is circulated through the line or after pumping has <br /> stopped is not necessary before conducting a valid test . <br /> • A waiting time after delivery of product is not necessary before a valid test can be <br /> conducted . 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.