My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0085076_OWTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AHERN
>
29700
>
4200 – Liquid Waste Program
>
SR0085076_OWTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2022 4:13:58 PM
Creation date
9/29/2022 9:09:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
FileName_PostFix
OWTS
RECORD_ID
SR0085076
PE
4201
FACILITY_NAME
AHERN TRUCK STOP
STREET_NUMBER
29700
Direction
S
STREET_NAME
AHERN
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
25502014
ENTERED_DATE
3/29/2022 12:00:00 AM
SITE_LOCATION
29700 S AHERN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
207
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
23 <br /> Paul W. Donoho, R.E.H.S. #6227 <br /> (530) 701-9972 <br /> AdvahTexO 01, M MANUAL <br /> COMMERCIAL TREATMENT SYSTEMS <br /> Maintenance • • <br /> Quarterly Maintenance Semi-Annual Maintenance <br /> Testing for Biochemical Oxygen Demand(BOD);Total Suspended Solids Inspect the spray of the <br /> {TSS);Fats,Oils,and Grease(FOG);Ammonia(NHS;Nitrate(NO);and nodes in the Advanl <br /> pH should he done according to regulatory requirements.If testing is pods.Look for reduced <br /> not required by the regulatory jurisdiction,samples should be taken or uneven spray patterns <br /> quarterly for the first year to establish a baseline.Subsequent testing as well as clogged spray <br /> after the first year may be reduced based on the establishment of this nozzles or biological <br /> baseline.Regular samples will provide valuable informaton for ongoing growth on the spray <br /> maintenance and froubleshooting.Effluent testing procedures may be nozzles.Observe and <br /> found in the residential Advanrex 0&M Manual in Appendix B.All results measure the residual <br /> obtained should be reported to the appropriate people,including Orenco's pressure.Refer back to <br /> Engineered Systems Department, the Start-up&Operation <br /> For the first year only,check voltages and amperages of all pumps and section for initial <br /> record them on the Field Maintenance Report Form provided in Appendix measurements of residual pressure.If the observed residual pressure <br /> B.Refer to the start-up voltages and amperages recorded in the"Start- exceeds the initial residual pressure(3 psi)more than 15-20%,it can be <br /> up&Operation'section of this document.If the voltage drop or the assumed that some of the nozzles are plugged and the laterals require <br /> amperage exmods National Electric Code(NEC)requirements(see chart flushing.To flush the laterals,open the ball valves at the end of one lateral. <br /> provided in'Inspection Points—Pumps"section of this document),have At the control panel,toggle the"AUTO-OFF-MAN'switch to'MAN"and let <br /> an electrician verify the service line and check the pump windings.If there the pump run to flush any material from the lateral.Repeat for each lateral <br /> is no discernible difference in voltage or amperage,this procedure may be until all of the laterals have been flushed.Recheck the residual pressure <br /> performed annually. to ensure the laterals have been sufficiently cleared. <br /> If there is still a significant difference in initial and current residual <br /> pressure,use an OrencoAX lateral cleaning brush or a high-pressure <br /> washer to clean the laterals. <br /> To clean out the spray nozzles,turning the laterals so the spray nozzle <br /> turbines are pointed up and then hosing each turbine off.For excessive <br /> buildup in the spray nozzles,remove the nozzles and replace them with <br /> clean nozzles.Soak the plugged nozzle in TSP or any other approved <br /> cleaning agent for 30 minutes.When a spray nozzle is clear,you can <br /> see the spray nozzle turbine spin freely and the spray distribute evenly <br /> across the textile media.If the nozzles are substantially plugged after six <br /> months,then it may be prudent to inspect the residual pressure every <br /> three months and adjust scheduled testing and flushing of the laterals <br /> accordingly. <br /> Visually inspect the recirculating valve and verify that the liquid level in <br /> the tank is within the normal range.Consult the design plans for proper <br /> operating level.If the liquid level is low,the ball mechanism could be <br /> jammed in the seated position.Remove,disassemble,and inspect.It the <br /> liquid level is high,the valve may require cleaning because it is not making <br /> a tight seal when seated.Remove,disassemble,and inspect. <br /> Capyrlghf Oreoco systems®,Inc.Pmimrry of Orenco Systems",Inc.Do not reproduce or distribute whhoet written aufhoriza5on from Orenco:800-348-9543. • AIM-010-M-3,Rev.2.1,05115 <br />
The URL can be used to link to this page
Your browser does not support the video tag.