My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOUNTAIN HOUSE
>
19677
>
1600 - Food Program
>
PR0548088
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 11:47:16 AM
Creation date
12/28/2022 12:53:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0548088
PE
1624
FACILITY_ID
FA0027436
FACILITY_NAME
MOUNTAIN MIKE'S PIZZA
STREET_NUMBER
19677
STREET_NAME
MOUNTAIN HOUSE
STREET_TYPE
PKWY
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
01
SITE_LOCATION
19677 MOUNTAIN HOUSE PKWY
P_LOCATION
03
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 SC-111110FP UTILITY CABINET RIGHT <br />04 - UTILITY CABINET <br />RIGHT <br />HOOD # 1 <br />1 LIGHT <br />1 FAN <br />SMART CONTROLS THERMOSTATIC CONTROL <br />EXHAUST <br />SUPPLY <br />1 <br />1 <br />0.750 <br />1.000 <br />115 <br />115 <br />8.9 <br />11.6 <br />NO TAG PACKAGE #LOCATION SWITCHES <br />LOCATION QUANTITY <br />OPTION FANS CONTROLLED <br />TYPE ΙΈ HP VOLT FLA <br />DESCRIPTION OF OPERATION: <br />4996088 <br />Mountain Mike's Pizza - Mount... <br />SC-111110FP <br />7/20/2021 <br />INSTALL <br />ECP #1-1 <br />120V 1 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fan(s) On/Off Thermostatically Controlled. Room temperature sensor <br />shipped loose for field installation. <br />BREAKER PANEL TO PRIMARY CONTROL PANEL <br />Responsibility: Electrician <br />BREAKER PANEL PRIMARY CONTROL PANEL <br />BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED <br />BREAKER 1PH <br />CONTROL POWER. DO NOT WIRE <br />TO GFCI OR SHUNT TRIP BREAKER. <br />Hot <br />Neutral <br />H1 <br />N1120 V <br />15 A <br />Ground GND <br />1ST HOOD LIGHT BREAKER SHARED W/ CONTROL <br />POWER. SWITCH #1 <br />BREAKER PANEL TO FANS <br />Responsibility: Electrician <br />BREAKER PANEL FANS <br />BREAKER 1PH <br />MCA: <br />MOCP: <br />POWER TO <br />ECM FANS <br />HOT <br />NEUTRAL <br />115V <br />11.1A EXH-1 <br />Ground <br />20A <br />BREAKER 1PH <br />MCA: <br />MOCP: <br />POWER TO <br />ECM FANS <br />HOT <br />NEUTRAL <br />115V <br />14.5A SUP-2 <br />Ground <br />25A <br />CONTROL PANEL TO ACCESSORY ITEMS <br />Responsibility: Electrician <br />CONTROL PANEL COMPONENT <br />ALL SWITCHES FACTORY WIRED <br />CAT-5 CONNECTION <br />CONTROL PANEL <br />SWITCHES <br />TO J4 <br />CONTROL PANEL <br />HOOD LIGHTS <br />TO <br />1400 W MAX WIRE TO J-BOX ON TOP OF HOOD <br />B1 <br />W1 <br />GND <br />BLACK <br />WHITE <br />GREEN <br />HOOD LIGHTS 1 <br />WIRE TO CONTROL BOARD. INSTALL <br />SENSOR IN ROOM AWAY FROM HEAT <br />SOURCES. DO NOT INSTALL SENSOR <br />CONTROL PANEL <br />KITCHEN TEMP <br />TO <br />SENSOR <br />ON THE CEILING GRID, SEE MANUAL. <br />T1A <br />T1B ROOM TEMP <br />FACTORY WIRED TEMPERATURE <br />SENSOR. MOUNTED IN HOOD CAPTURE <br />CONTROL PANEL <br />CAPTURE VOLUME <br />TO <br />SENSOR VOLUME. <br />T2A <br />T2B HOOD 1 <br />CAPTURE 1 <br />CONTROL PANEL <br />GAS VALVE <br />TO <br />120V ONLY <br />ONLY ENERGIZED THROUGH LCD <br />HMI WHEN FIRE SYSTEM ARMED. <br />GAS <br />N1 <br />HOT TO GAS VALVE <br />NEUTRAL <br />GAS SOLENOID <br />J7 J8 <br />MSC #1 <br />J7 J8 <br />MSC <br />CONTROL PANEL <br />MSC <br />TO <br />J5 <br />IF MORE THAN ONE MSC IS PRESENT <br />WIRE IN SERIES BY MEANS OF <br />J7 AND J8 CAT-5 JACKS. DO NOT <br />EXCEED 5 MSC BOARDS ON ONE <br />ECPM03 JACK. <br />THE FOLLOWING CONNECTIONS <br />MAY OR MAY NOT BE <br />REQUIRED BASED ON JOBSITE <br />SPECIFICATIONS <br />CONTROL PANEL <br />EXTERNAL <br />SIGNAL FOR <br />SHUNT TRIP <br />ST TERMINAL IS ENERGIZED <br />IN FIRE CONDITION. <br />CONTROL PANEL <br />EXTERNAL <br />SIGNAL FOR <br />CONTACTOR COIL <br />KS TERMINAL IS DE-ENERGIZED <br />IN FIRE CONDITION. <br />ST <br />N1 NEUTRAL FROM SHUNT COIL <br />HOT TO SHUNT COIL SHUNT COIL <br />KS <br />N1 NEUTRAL_TO_CONTACTOR_COIL <br />HOT_TO_CONTACTOR_COIL CONTACTOR_COIL <br />CONTROL PANEL <br />EXTERNAL <br />TO <br />SWITCH <br />SIGNAL SWITCH THROUGH BMS <br />WILL ACTIVATE ZONE1 FANS AND <br />LIGHTS <br />H1 <br />IO1 <br />BMS SWITCH <br />CNO <br />CONTROL PANEL <br />GAS VALVE <br />TO <br />24V DC ONLY <br />ONLY ENERGIZED THROUGH LCD <br />HMI WHEN FIRE SYSTEM ARMED. <br />(NOT NEEDED IF USING 120V <br />GAS VALVE). <br />35 <br />N1D <br />POSITIVE TO GAS VALVE <br />NEGATIVE <br />GAS SOLENOID <br />SYSTEM DRY <br />SPARE FIRE <br />CONTACT <br />CONTROL PANEL <br />SPARE CONTACTS WILL MAKE C2 TO <br />AR2 WHEN SYSTEM IS ARMED. THEY <br />ARE USED TO DISABLE EQUIPMENT <br />OR PROVIDE SIGNALS. (NOT FOR <br />BUILDING FIRE ALARM WHICH MUST <br />BE WIRED DIRECTLY TO THE ANSUL <br />ALARM INITIATING SWITCH LOCATED <br />IN ANSUL AUTOMAN) <br />C2 <br />AR2 <br />COMMON <br />NORMALLY OPEN <br />CONTROL PANEL TO FIRE SYSTEM <br />Responsibility: ALARM CONTRACTOR <br />CONTROL PANEL COMPONENT <br />CONTROL PANEL <br />BUILDING <br />SIGNAL FOR <br />FIRE ALARM <br />PANEL <br />AL1 <br />AL2 <br />J9 <br />BUILDING <br />ALARM PANEL <br />FIRE INPUT <br />WIRE DIRECTLY TO CORE CIRCUIT <br />BOARD. AL1 WILL MAKE AL2 IN FIRE <br />CONDITION. <br />CONTROL PANEL <br />BUILDING <br />SIGNAL FOR <br />TROUBLE TROUBLE RELAY CONTACTS WILL <br />MAKE TBC TO TBL IN TROUBLE <br />CONDITION. <br />BUILDING <br />ALARM PANEL <br />ALARM <br />TBC <br />TBL <br />COMMON <br />NORMALLY CLOSED <br />CONTROL PANEL TO FIRE SYSTEM <br />Responsibility: CERTIFIED INSTALLER <br />CONTROL PANEL COMPONENT <br />FIRE STAT SUPERVISED LOOP <br />May be mixed factory and field wiring. See <br />Installation Schematic. Multiple fire sensors <br />possible. <br />HIGH TEMP WIRE (842 F), PN: SLPCON-xFT <br />required for all Supervised Loop wiring in contact <br />with a hood. All other wiring shall be PN: 6320UL, <br />Belden or similar. <br />21 <br />22 <br />23 <br />24 <br />FS-01 <br />BK WH <br />Fire Stat <br />FS-02 <br />BK WH <br />Fire Stat <br />CONTROL PANEL <br />MOUNTED FIRE <br />TO DUCT <br />DETECTION <br />STAT(S) <br />FIRE STATS <br />CONTROL PANEL <br />SYSTEM PULL <br />TO FIRE <br />STATION <br />MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM <br />LOOP. <br />Multiple manual actuation possible. <br />Multiple manual actuation possible. <br />A Plug jumper with wires from pin1 to pin4 and from pin2 to <br />pin3 is mounted on J10, remove the jumpers and <br />wire in the supervised actuation loop. <br />Microswitch MS-01 is optional for fire <br />system interlock. <br />Auxiliary Interlock (AUX-01): <br />Wire AU1 / AU2 of adjacent Master FS panel(s) in each <br />manual activation loop for simultaneous activation. See Fire <br />system drawings for more information. <br />101 <br />102 <br />103 <br />104 <br />AUX-01 <br />AU1 AU2 <br />PULL STATION <br />MS-01 <br />CNO <br />Micro SW <br />MAD-01CNO <br />Manual <br />Actuation <br />Device <br />Adjacent <br />FS <br />Panel <br />CAT-5 CONNECTIONCONTROL PANEL <br />MASTER FS <br />TO <br />BOARD. <br />PLACE END OF LINE PLUG <br />EOL120AIN EMPTY JACK. PN: EOL120A <br />CORE PCB <br />ADDITIONAL DEVICES MAY BE INLINE. <br />ECPM03 <br />UNLESS VFD, PCU, <br />OR OTHER COMPONENT IN SERIES. <br />J3 J5 <br />J6 <br />CONTROL PANEL <br />MASTER FS <br />TO <br />PANEL <br />WIRE TO LIKE TERMINALS IN ALL <br />CORE PANELS THAT MUST ACTIVATE <br />TOGETHER. SET MASTER & SLAVE <br />DIP SWITCHES PER FIRE SYSTEM <br />SHIELDED TWISTED PAIRINTERLOCK NETWORK MASTER CORE <br />MANUAL. <br />CA <br />CB <br />CC <br />BLACK <br />RED <br />SHIELD <br />CA <br />CB <br />CC <br />CONTROL PANEL <br />FIRE SYSTEM <br />TO EXTRA <br />PRESSURE <br />SWITCH <br />WHRDPS-2 <br />NO C <br />WIRING DIAGRAM FOR ALL OTHER <br />PRESSURE SWITCHES IN PARALLEL. <br />PS <br />H1D <br />DESCRIPTION OF OPERATION: <br />4996088 <br />Mountain Mike's Pizza - Mount... <br />SC-111110FP <br />7/20/2021 <br />INSTALL <br />ECP #1-2 <br />Fire System #1 TANK Fire Suppression - 4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. <br />Installed in Hood Utility Cabinet with integral hood prewire panel. <br />FS-1: MASTER <br />DESCRIPTION OF OPERATION: <br />4996088 <br />Mountain Mike's Pizza - Mount... <br />SC-111110FP <br />7/20/2021 <br />INSTALL <br />ECP #1-3 <br />Fire System #1 TANK Fire Suppression - 4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. <br />Installed in Hood Utility Cabinet with integral hood prewire panel. <br />FS-1: MASTER <br />DESCRIPTION OF OPERATION: <br />4996088 <br />Mountain Mike's Pizza - Mount... <br />SC-111110FP <br />7/20/2021 <br />INSTALL <br />ECP #1-4 <br />Fire System #1 TANK Fire Suppression - 4.0. Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a Listed Release Mechanism. <br />Installed in Hood Utility Cabinet with integral hood prewire panel. <br />FS-1: MASTER <br />SHEET NO. <br />SCALE: <br />DWG.#: <br />DRAWN <br />DATE: <br /> BY: <br />REVISIONS <br />www.captiveaire.com ACCORDANCENo. 96BUILTNFPAWITHINSLIDTER4996088 <br />MASTER DRAWING <br />AH-86Mountain Mike's Pizza - Mountain House CAMountain House, CA, 95391Southern California Office3002 Dow Ave., Suite 410, Tustin, CA, 92780 PHONE: (714) 957-1500 FAX: (919) 227-5975 EMAIL: reg86@captiveaire.comCAPTIVEAIRE DRAWINGS <br />M-4.4 <br />PRINTED DATE: 07-21-2021PROJECT NAME/ADDRESS: <br />STAMP <br />@Mountain House <br />ARCHITECT <br />ARCH PROJECT #: <br />JOB NUMBER <br />DRAWN BY <br />SHEET CONTENT <br />SHEET NO <br />ISSUE DATE: <br />REVISIONS: <br />EM <br />21-___ <br />CHECK BY <br />ADR <br />ARCHITECTURE <br />GWA <br />1000 Corporate Center Drive <br />Suite 550 <br />Monterey Park, CA 91754 <br />tel: (626) 288-6898 <br />Member of The American Institute of Architects <br />REN. 04-30-2023
The URL can be used to link to this page
Your browser does not support the video tag.