SU0015298
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
800
>
2600 - Land Use Program
>
PA-2200266
>
SU0015298
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/22/2023 11:02:06 AM
Creation date
12/29/2022 4:09:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0015298
PE
2632
FACILITY_NAME
PA-2200266
STREET_NUMBER
800
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330-
APN
23903008
ENTERED_DATE
12/13/2022 12:00:00 AM
SITE_LOCATION
800 W MOSSDALE RD
RECEIVED_DATE
8/22/2023 12:00:00 AM
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
required . Additionally , pursuant to Development Title Section 9 - 406 . 060 , the minimum size of each <br /> parking stall must be 94eet wide by 194eet deep . <br /> The site plan does not depict surfacing material in the parking lot area , driveways , or maneuvering <br /> areas . Pursuant to Development Title Section 9 - 406 . 060 ( i ) , all parking spaces , driveways , and <br /> maneuvering areas shall be surfaced and permanently maintained with asphalt concrete or <br /> Portland cement concrete . <br /> A revised site plan depicting the required parking stall dimensions and surfacing material must be <br /> submitted by the applicant prior to completion of the environmental review for the project . <br /> Fencinq and Screening <br /> The site plan depicts a fence surrounding the proposed project site , and two 25400t-wide gates . <br /> The fence material , height , and gate setbacks are not depicted on the site plan . <br /> Pursuant to Development Title Section 9 -400 . 040 ( a ) ( 4 ) , all gates shall meet the applicable fence <br /> height requirement and shall be setback a minimum of 10 feet unless there are at least 16 feet <br /> between the property line and the edge of the travelled roadway , in which case the setback <br /> requirement is waived . <br /> Additionally , pursuant to Development Title Section 9 -400 . 040 ( b ) ( 1 ) , fencing within required yards <br /> can be up to 7 feet in height ( open ) or up to 5 feet of solid ( closed ) . Outside of required yards , <br /> fencing heights may exceed these limits . <br /> The applicant must submit a revised site plan depicting fencing and screening details consistent <br /> with Development Title regulations . <br /> Landscaping <br /> The site plan depicts a 10400t landscaping strip along the front property line with an additional <br /> 6 , 000 square feet of landscaping spread throughout the project site . No further details regarding <br /> landscaping are depicted . <br /> Pursuant to Development Title 9 -402 . 030 ( x ) , all required front setbacks , except for areas to be <br /> used for driveways and entries , shall be landscaped . Also , pursuant to Development Title Section <br /> 9402 . 040 ( a ) , landscaping must consist of a combination of ground cover materials , shrubs , and <br /> trees . Additionally , pursuant to Development Title Section 9 -402 . 03 ( c ) , 1 tree is required for every <br /> 5 parking stalls , and shall be evenly spaced throughout the parking lot . <br /> The applicant must submit a revised site plan depicting the required landscaping prior to completion <br /> of the environmental review for the project . <br /> Lighting and Illumination <br /> The site plan does not depict lighting for the parking area . Pursuant to Development Title Section <br /> 9 -406 . 060 ( m ) , parking lot and security lighting must be installed if the parking area is to be used at <br /> night and all lighting must be designed to confine direct rays to the premises with no spill - over . As <br /> a result , the required lighting must be depicted on a revised site plan prior to completion of the <br /> environmental review for the project . <br /> Nototomne Cultural Preservation <br /> On January 3 , 2023 , the Community Development Department received a response letter from the <br /> Nototomne Cultural Preservation requesting that the project be denied because the site has been <br /> identified as a sensitive location for burial discoveries . It is recommended that the applicant contact <br /> the Tribe as soon as possible to discuss their concerns . The Nototomne Tribe ' s comments will be <br /> considered in the Community Development Department' s determination on this project . <br /> PA-2200266 ( SA ) 02 - 12 - 2023 DC Memo 2 <br />