Trapzilla° Grease Interceptor t Trapzilla° Grease Interceptor W4 " Nib, REVISIONS
<br /> o � o
<br /> PATHERfMVTCO°Technology TZ-400 Specifications ATHERMA-0 Technology TZ-400 Specifications By
<br /> O MAIN (E)S/S PRODUCT FEATURES NOTES
<br /> STREET
<br /> SEWER LINE Constructed of corrosion resistant materials suitable for installation 1. READ instruction manual included with system before installing/operating. / \
<br /> 405 LBS (TZ-400-ECA) w in virtually any location. 2. Unit requires 6"(15.24 cm)of clearance all the way around the lid from walls or other structures to allow for servicing.
<br /> GREASE INTERCEPTO C/O a Compact footprint. 3. Make piping connections with rubber"No Hub"connectors.
<br /> C/O a p•p' g
<br /> w Baffle structure retains separated grease increasing retention 4.5 in 4. Keep outlet piping as straight as possible. Use only"sweep"connections.
<br /> \ 4 W.P CO efficiency of separator. �'�[u.a cm] 5. Install vent on outlet piping.
<br /> ~o ` ; < Included lid rated for foot-traffic only Inlet Pipe 6. If installing in conjunction with other Trapzilla products, include cleanout port before, after, and/or between each unit.
<br /> O ` 7. Do not install"P"Trap on outlet connection of tank(unit already has internal gas trap).
<br /> \ CV SPECIFICATIONS ►-i i i i�i-►- 8. Do not reduce pipe size on outlet piping
<br /> LU 1-1-1-1-1-►-1-1-1-
<br /> a O V.P. w 1-►-►-►-1 1-1-►-►-► 9. Do not pressure test unit.
<br /> Construction: Single-Piece Rotational) Molded ►-1-1-1-1 ►-1-1-1-1
<br /> - 9 Y
<br /> - C-- ►_1_1_1_ • _I_I-1_I
<br /> Polyethylene Exterior Tank with Inlet/ 1_1_1_► _1_I 1_I_ ►_1_1_1 Equipment must be installed in compliance with all applicable laws, regulations and codes, including plumbing codes. Instal-
<br /> ' L CK 1 E/Pr--- Outlet Inverts secured using Patented i i i 1 ►-i ► ► i i�% 1 i i ?- lation should be performed b a qualified plumbing contractor.
<br /> � c7 �
<br /> •W�H � 1 1 9 P Y q p 9
<br /> -- I',1 z O -►-►- 1-►-1-►-1-1-►- -1-►
<br /> O Interior Radial Compression Ring
<br /> - 8 �1w LL
<br /> SHELVING
<br /> 11�1�1 �► 11 1�1�1�
<br /> _ L Flow Rating: 75 GPM(4.73 I/s) 1-1- 1 1- 1-1- JOB SPECIFICATION
<br /> Fes= 2g Q = Lu z Liquid Capacity: 70 gallons(265 1) 38.3 in • 1 1 ►1 - 1► • 42.5 c
<br /> „ P o U a rl ► „�� ► �_I- [los.o cm] Grease separator(s)shall be Thermaco Trapzilla h dromechanical grease interceptors stems as manufactured b Thermaco,
<br /> Grease Capacity: 55 al. 208.2 I [9zz cm] 1-1- 1 1- 1-1- p Y gY O Y
<br /> ..iv Lu p Y 9 ( ) 1-1-1 1 1 1-1-1
<br /> 8' x 6' w 1-►-1 1 �. ,... �. -1-►- Inc.,Asheboro, North Carolina as noted on plans.
<br /> IIVK 11 6 Q WALK-IN 12 405.6 lbs.(184 Kg) r►-►- _ _ 1-►-►
<br /> -1-1- 1-►-►-►-►-►-►- 1-1-►
<br /> = L � Solids Capacity: 22.6 gallons(85.6 1) 1► ► ► ► ► ►,A� 1 1 1
<br /> _-____
<br /> 2"01 V.P. --- cn FREEZER 1 i-1-1-► ►-1 ► ►-►-1-1 SEPARATOR SPECIFICATIONS
<br /> Inlet/Outlet: 4" 101 mm 1-1-►-1- a• _ 1-1-1-1
<br /> -7 11 _ ( ) 1-1-1-1-1- 1-1-1-1-1
<br /> z _ _ z ►-1-1'1-► ►'1-1-1-1 Furnish and install Thermaco Trapzilla Model No.TZ-400, rotational) moldedpolyethylene rease interceptor(s)
<br /> a - Q L p Product Weight: 71 lbs.(33 Kg) 1-►-1-1-1 1-1-►-1-1 p Y 9
<br /> 1-1-1-1-1-1-1-1-1-
<br /> _ 1_1_1_1_1_1_►_ for above or below ground installation, shall be rated at 75 GPM (4.73 I/s) with 55 gal. (208.2 1)/405.6 lbs. (184 Kg) of total
<br /> 1 w 1(D 20 rZZ
<br /> Z I TOP VIEW 1 ►- grease storage capacity with flat separation efficiency curve capable of holding 79%of volume in free-floating fats, oils, and
<br /> J 5 Q z ;zo a a U grease at capacity,with removable cover for grease and solids removal access, integral anti-flotation anchor ring for in-ground
<br /> E- w 1 > _J❑ w = 8' x 6' r -- E 5 PCC E Outlet Pipe 4.5 in installation,integral horizontal baffle,laminar inlet flow diverter,integral vessel vent,separate storage compartments for grease
<br /> `I - cb13"0G.P. � w wQ WALK-IN I� �----�[i1.4cm]
<br /> 1 (D 1 = =In 0 z m and heavier than water solids,a unitary tank body and 4"(101 mm)inlet/outlet structures without gasket interfaces, utilizing an
<br /> •1� 1 cn w � a COOLER J ® interior radial compression ring conjoining invert to tank outlet/inlet structures without bulkhead fittings and/or gaskets,invert top
<br /> 2"0 V.P. 1 I F/D --- 1 Z 7 a 2 and bottom secured attachment points,sloping conical bottom for solids retention,integral sewer gas trap,and a fully removable
<br /> 2 1 20 1 L-o w U) polyethylene self-positioning cover with sealed thread fasteners. 0M0
<br /> 0 c� H
<br /> 2"0 G.P. d z Q
<br /> Ln
<br /> 10"CLEARANCE FROM TOP OF TANK 36 in �
<br /> LuREQUIRED FOR LID REMOVAL/PUMPING [91.4 cm]
<br /> � - SUBMITTAL OPTIONS Q
<br /> 2"0 V.P. _ Lu 1= F/S1 ❑ ECA-TZ-29 Extension Collar with additional 29"(73.7 cm)of extension U
<br /> r 2 W.P. c9 1� L-J2"Ql . ------ 1 0
<br /> --rtc� _ o►mFT ❑ TZSP-40-ECA Sampling Port with 4"Inlet/Outlet, 0.5"fall with 29"(73.7 cm) Extension Collar Assembly Z
<br /> 7� L___J z INLET
<br /> L z J 3 0 > 2"0 V.P. 0 z"VENT OUTLET ❑ TZSP-48-ECA Sampling Port with 4"Inlet/Outlet, 7.8"fall with 29"(73.7 cm) Extension Collar Assembly 2
<br /> 70 W.P. a w ❑ TSS-70 Solids Interceptor for additional Solids Capacity O
<br /> CE 2" W.P. � d 1(n 1 4"PIPE � Q
<br /> M ER 2 cRSFp�A c~i3 1 i�� -�i 38.5 in INLET/OUTLET ❑ head height greater VFCA-75 Vented Uthan ioControl Assembly for installation at plumbing fixture level to limit flow to 75 gpm for installations with 0 rn � }
<br /> VI '^ - M
<br /> >Q> Pte- [97.8 cm] 28.5 in W
<br /> 1r---� 11 Q1 > 1111 �G\ [724 cm] ❑ MFSH-44 Molded Flow Splitter Assembly for evenly diverting flow to two separate 4"Trapzilla units Z ~ N l
<br /> 01 19 -1-iV y 29 in ❑ FTCA-22 Fabricated To Cover Assembly with 22" 55.9 cm diameter diamond late aluminum surface for heavy duty Z
<br /> 20 11 LL
<br /> 1 18 "v [73.7 cm] p Y ( ) P Y Y (r � r--
<br /> (D
<br /> (D W/T w1 2"0 G.P.I i F_ foot-traffic, pallet jacks,food carts etc. Replaces standard 22"STC-TZ-22 Cover(not rated for vehicle traffic) - � o
<br /> z a F/Si Only use in conjunction with ECA-TZ-29 (n uJ w
<br /> Lu w
<br /> 14.1 in
<br /> w 1� _� a J--_= 2"0 V.P. [35.9 cm] ❑ FTCA-36 Fabricated Top Cover Assembly with 36" (91.4 cm) diameter diamond plate aluminum surface for heavy duty w W W �1
<br /> = SHELVING �1 Lu 2" W.P��_
<br /> � foot traffic, pallet jacks,food carts etc. Replaces Adapter Ring and Standard Cover(not rated for vehicle traffic) u) Z
<br /> L___JI 0 ANDWI � SIDE VIEW END VIEW > LLI O
<br /> TABLE z1 7 - _3 ❑ H20/Traffic Rated Installation, see link for installation drawings > � 2 _J
<br /> z -- (� =-- 1 31 in
<br /> Q a-
<br /> ---- ----� 1 [78.7 cm]
<br /> 10 1L �C�1 1 [936 icm ] p W
<br /> STEAM 11 1 8 OKER1
<br /> TABLE Q 6 I I N
<br /> 3"0 WAS E PIPE TII 9 ---WET J coo
<br /> F.C.O. a z h 15/D 7 1 =__1 1 ©2019 Thermaco, Inc. •All rights reserved•Patented/Patents Pending•Specifications subject to change without notice c
<br /> a 1 ___ I 1 1 02019 Thermaco, Inc. •All rights reserved•Patented/Patents Pending•Specifications subject to change without notice
<br /> O X11 -� 6/19 Thermaco, Inc. •PO Box 2548•Asheboro,NC 27204-2548•(336)629-4651 www.trapzilla.com 1
<br /> U/D
<br /> 00 - �' � • FREEZE h ��' 1 �_ -_�� 1 g/tg Thermaco, Inc.•PO Box 2548•Asheboro,NC 27204-2548•(336)629-4651 •www.trapzilla.com 2
<br /> c`iF/D 42" " � th "0G.P.
<br /> 6
<br /> � § Qr a D/F
<br /> tS2 D SII rZ a -----�
<br /> c GENDER 2"0 V.P. iQ 14 Lu 6 11 I --D/F- I OUTLET VENT-
<br /> r VESSEL VENT TO
<br /> 4, T= In EXTEND TO GRADE
<br /> 0 Q WOK ATMOSPHERE THE TRAPZILLA COVER
<br /> o) F+ 13 AND COVER OR IS PLACED ON THE TOP
<br /> + tS2 I[ ECA-TZ-18 MOST EXTENSION COLLAR Z M
<br /> FTS( CONNECT FACILITY GREASE INTERCEPTOR
<br /> 2'f11 P. 1 EXTENSION � CY)
<br /> L i�t �r C.O. COLLAR GRADE �/ �
<br /> -- 5 Q
<br /> 12 I � 1� 1 2"0 V.P. � .� � � M U
<br /> W/T 1 �T
<br /> I C, "��1 " FIXTURE DFU X QUANTITY TOTAL Q Q
<br /> 1 RAN
<br /> � 1 J --J TWO WAY CLEAN OUT U
<br /> ~ W
<br /> L_15' HOOD ) � ,'�">_ � ' TWO PLACES-EXTEND CPC TABLE 702.1DFU
<br /> H
<br /> TO GRADE W Z
<br /> r � Q
<br /> 22"0 v P 3-TUB SINK 4 1 4
<br /> 2"f1J W.P. r �
<br /> Si r
<br /> 4"OUTLET<- TZ-400 �4"OUTLET LU fn
<br /> F.C.O. L �-_J TRAPZILLA UNIT PREP SINK 3 1 3 r W
<br /> CASH TABLE
<br /> TZ-600
<br /> (34 b�6 SIV) -- ~ Z Z
<br /> L TRAPZILLA UNIT " `. MOP SINK 3 1 3 j-
<br /> ` LLJ G
<br /> t LU
<br /> FLOOR DRAIN 2 2 4 NQ (.0
<br /> T
<br /> A/ N
<br /> +' DINING AREA FLOOR SINK 2 1 2 tl LL
<br /> CONCRETE SURROUNDIN
<br /> UNIT BODY AND ------------------------------------------------------------------------------------------------
<br /> EXTENSION COLLAR TOTAL DFU = 16
<br /> USED 405 LBS & 75 GPM GREASE INTERCEPTORS. PLUMBING
<br /> LAY-OUT
<br /> NOTES
<br /> GREASE INTERCEPTOR DETAILOxEASoOIV4, �j
<br /> No.
<br /> 6-30-23
<br /> �TgTF OF C A
<br /> 11X3 Designed by : T.W
<br /> ,_v-_V�
<br /> _
<br /> Date : Mar 26, 2022
<br /> LOCK BOX
<br /> Scale : AS SHOWN
<br /> Drawn : W.P.D.
<br /> Job :
<br /> WASTE PIPING LAYOUT SHEET
<br /> SCALE: 1/4 11=11-011
<br /> OF SHEETS
<br />
|