SAN J O A Q U I N Environmental Health Department <br /> ` <br /> COUT Time In: 10:00 am <br /> Time Out: 11:15 am <br /> i�C1FaR'' Greorness grows her". <br /> Food Program Service Request Inspection Report <br /> Name of Facility: JUNOON INDIAN CUISINE Date: 08/22/2023 <br /> Address: 1261 W YOSEMITE AVE , MANTECA 95337 <br /> Requestor: ELIAS HERMOSILLO, DESIGN BUILD DRAFTING Telephone: (916)502-5288 <br /> Program Element: 1601 -FOOD PLAN CHECK Request#: SR0085831 <br /> Inspection Type: 523-Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code commencing with section 7; <br /> 113700.All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and have the potential to cause foodborne illness.All major violations must be corrected immediately.Non-compliance may warrant immediate closure of <br /> the food facility. <br /> #1 Demonstration of Knowledge <br /> OBSERVATIONS:Food handler cards to be provided within 30 days of employees hiring dates. <br /> CALCODE DESCRIPTION:All food employees shall have adequate knowledge of and be trained in food safety as it relates to their <br /> assigned duties. (113947)Food facilities that prepare,handle or serve non-prepackaged potentially hazardous food,shall have an <br /> employee who has passed an approved food safety certification examination. (113947-113947.1)Any food handler hired after June 1, <br /> 2011 shall obtain a Food Handler Card within 30 days(113948). <br /> #41 Plumbing Maintained;Approved Back Flow Device <br /> OBSERVATIONS:Gas Water heater 76,000BTU is installed that is not meeting the minimum water demand requirement. <br /> Provide Water heater with minimum 107,000BTU before operating. <br /> Pipes, draining, bar hand sink, bar dump sink, bar ice chest, dish washer, prep sink and 3 comp sink, are lacking air gaps. <br /> Provide air gaps at least 1 inch off the floor sinks before operating. <br /> Mop sink is lacking water faucet unit with anti siphonage device. Provide water faucet with hot and cold water before <br /> operating. <br /> Bar hand sink is not secured. Secure the hand sink before operating. <br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required <br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing <br /> ordinances,shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose <br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171, <br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269) <br /> #45 Floors,Walls, Ceilings; Clean and Maintained <br /> OBSERVATIONS:Walk in cooler coved galvanized stainless steel sheet has gaps with its connection with the floor tiles. I <br /> observe a hole on the floor of the walk in cooler. Properly seal the gaps and the hole before operating. <br /> CALCODE DESCRIPTION: The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All floor <br /> surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br /> cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in original <br /> unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143(d), <br /> 114266, 114268, 114268.1, 114271, 114272) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> SR0085831 SC523 08/22/2023 <br /> EHD 16-23 Rev.07/05/2022 Page 1 of 2 Food Program Service Request Inspection Report <br />