My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
4900
>
2800 - Aboveground Petroleum Storage Program
>
PR0530044
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2025 10:39:59 AM
Creation date
7/30/2024 2:38:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0530044
PE
2832 - AST FAC 10 K - </=100 K GAL CUMULATIVE
FACILITY_ID
FA0014269
FACILITY_NAME
Inter-State Oil Co. - Stockton Cardlock
STREET_NUMBER
4900
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
Stockton
Zip
95215
APN
17916021
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4900 E Mariposa RD Stockton 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />June 14, 2024 <br /> Facility Address: <br /> 4900 E Mariposa RD, Stockton <br /> Facility Name: <br /> Inter-State Oil Co. - Stockton Cardlock <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />necessary resources to fully implement the Plan. <br />REGULATION GUIDANCE: If you are the owner or operator of a facility subject to this part you must prepare a Plan in <br />accordance with good engineering practices. The Plan must have the full approval of management at a level of <br />authority to commit the necessary resources to fully implement the Plan. You must prepare the Plan in writing . If you <br />do not follow the sequence specified in this section for the Plan, you must prepare an equivalent Plan acceptable to <br />the Regional Administrator that meets all of the applicable requirements listed in this part , and you must supplement it <br />with a section cross-referencing the location of requirements listed in this part and the equivalent requirements in the <br />other prevention plan. If the Plan calls for additional facilities or procedures, methods, or equipment not yet fully <br />operational, you must discuss these items in separate paragraphs and must explain separately the details of <br />installation and operational start-up. <br />CORRECTIVE ACTION: Immediately obtain required management approval for the SPCC Plan for this facility. Provide <br />proof of correction to the EHD. <br />This is a repeat violation (Class 2) Violation. <br />Code of Fed Regulations 112.7(a)(3) 4010016 - Physical layout of the facility is adequately and accurately described <br />in SPCC. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to include an adequate facility <br />description. <br />-The SPCC Plan includes a description of an AST that is no longer on -site. <br />-The SPCC Plan does not adequately describe the locations of multiple storm drains. <br />-The SPCC Plan does not include an adequate description of where drainage from the AST secondary containment <br />goes. <br />-The facility description does not include proximity to navigable waters. <br />REGULATION GUIDANCE: (3) Describe in your Plan the physical layout of the facility and include a facility diagram, <br />which must mark the location and contents of each fixed oil storage container and the storage area where mobile or <br />portable containers are located. The facility diagram must identify the location of and mark as “exempt” underground <br />tanks that are otherwise exempted from the requirements of this part under § 112.1(d)(4). The facility diagram must <br />also include all transfer stations and connecting pipes, including intra-facility gathering lines that are otherwise <br />exempted from the requirements of this part under § 112.1(d)(11). <br />CORRECTIVE ACTION: Ensure that the SPCC plan includes a complete facility description. Provide proof of <br />correction to the EHD. <br />This is (Class 2) Violation. <br /> 14 <br />Code of Fed Regulations 112.7(a)(3), 25270.4.5(a) 4010015 - SPCC contains an adequate facility diagram. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to include an adequate facility <br />diagram. No facility diagram was included in the 2/19/16 SPCC Plan. The 12/4/14 plan observed on-site at the time of <br />inspection contained inadequate facility diagrams. Missing/inaccurate components include: <br />-Missing storm drains <br />-Missing fuel dispensers <br />-Missing emergency stop <br /> 16 <br />FA0014269 PR0530044 SC001 06/14/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 6 of 13 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.