WASTE FIXTURE UNITS- EXISTING STORE
<br />MARK
<br />DESCRIPTION
<br />MARK
<br />QUANTITY
<br />FIXTURE
<br />UNIT
<br />TOTAL NO. OF
<br />FIXTURE
<br />WC
<br />WATER CLOSET
<br />DORA CHAMPION WATER CLOSET
<br />HANDICAP 17"HIGH
<br />2
<br />3
<br />6
<br />LAV
<br />LAVATORY
<br />S-1
<br />2
<br />1
<br />2
<br />S-1
<br />3 COMP. SINK
<br />PREP. SINK S.S. FREE STANDING SINK
<br />1
<br />3
<br />3
<br />S-2
<br />PREP SINK
<br />WCO
<br />1
<br />3
<br />3
<br />S-3
<br />HAND WASH SINK
<br />TANKLESS WATER HEATER
<br />2
<br />2
<br />4
<br />MS -1
<br />MOP SINK
<br />FS -1
<br />1
<br />2
<br />2
<br />MS -1
<br />FLORESTONE MSR -2424
<br />MOP SINK
<br />24"X24"X12" DEEP SINK. HOT AND COLD WATER FAUCET
<br />WITH 4" CENTER DRAIN OPENING
<br />FD -1
<br />ZURIN Z -415 -NH -P
<br />FS
<br />FLOOR SINK
<br />1
<br />2
<br />3
<br />1 6
<br />FD
<br />FLOOR DRAIN
<br />MIXING VALVE
<br />2
<br />2
<br />4
<br />WATRE FILTER
<br />ET -1
<br />WILKINS NO. WXTP-12
<br />EXPANSION TANK
<br />SUSPENDED, 4 GALLON, DIAPHRAM TYPE, PRE -PRESSURED WITH WELDED EXTERIOR. BUTYL DIAPHRAM AND
<br />EPDXY COATED EXTERIOR.
<br />TOTAL FIXTURE UNITS 30
<br />WATER SUPPLY FIXTURE UNITS- EXISTING STORE
<br />MARK
<br />DESCRIPTION
<br />MARK
<br />QUANTITY
<br />FIXTURE
<br />UNIT
<br />TOTAL NO. OF
<br />FIXTURE
<br />WC
<br />WATER CLOSET
<br />DORA CHAMPION WATER CLOSET
<br />HANDICAP 17"HIGH
<br />2
<br />5
<br />10
<br />LAV
<br />LAVATORY
<br />S-1
<br />2
<br />2
<br />4
<br />S-1
<br />3 COMP. SINK
<br />PREP. SINK S.S. FREE STANDING SINK
<br />1
<br />2
<br />2
<br />S-2
<br />PREP SINK
<br />WCO
<br />1
<br />2
<br />2
<br />S-3
<br />HAND WASH SINK
<br />TANKLESS WATER HEATER
<br />2
<br />2
<br />4
<br />MS -1
<br />MOP SINK
<br />FS -1
<br />1
<br />2
<br />2
<br />MS -1
<br />FLORESTONE MSR -2424
<br />MOP SINK
<br />24"X24"X12" DEEP SINK. HOT AND COLD WATER FAUCET
<br />WITH 4" CENTER DRAIN OPENING
<br />FD -1
<br />ZURIN Z -415 -NH -P
<br />TOTAL FIXTURE UNITS 24
<br />1141 FIXTURE UNITS
<br />WASTE FIXTURE UNITS- KITCHEN
<br />MARK
<br />DESCRIPTION
<br />MARK
<br />QUANTITY
<br />FIXTURE
<br />UNIT
<br />TOTAL NO. OF
<br />FIXTURE
<br />WC
<br />WATER CLOSET
<br />DORA CHAMPION WATER CLOSET
<br />HANDICAP 17"HIGH
<br />-
<br />-
<br />-
<br />LAV
<br />LAVATORY
<br />S-1
<br />JOHN BOOS -31318244-21318
<br />-
<br />-
<br />S-1
<br />3 COMP. SINK
<br />PREP. SINK S.S. FREE STANDING SINK
<br />1
<br />3
<br />3
<br />S-2
<br />PREP SINK
<br />WCO
<br />1
<br />3
<br />3
<br />S-3
<br />HAND WASH SINK
<br />TANKLESS WATER HEATER
<br />2
<br />2
<br />4
<br />MS -1
<br />MOP SINK
<br />FS -1
<br />1
<br />2
<br />2
<br />MS -1
<br />FLORESTONE MSR -2424
<br />MOP SINK
<br />24"X24"X12" DEEP SINK. HOT AND COLD WATER FAUCET
<br />WITH 4" CENTER DRAIN OPENING
<br />FD -1
<br />ZURIN Z -415 -NH -P
<br />FS
<br />FLOOR SINK
<br />1
<br />6
<br />3
<br />18
<br />FD
<br />FLOOR DRAIN
<br />MIXING VALVE
<br />5
<br />2
<br />10
<br />WATRE FILTER
<br />ET -1
<br />WILKINS NO. WXTP-12
<br />EXPANSION TANK
<br />SUSPENDED, 4 GALLON, DIAPHRAM TYPE, PRE -PRESSURED WITH WELDED EXTERIOR. BUTYL DIAPHRAM AND
<br />EPDXY COATED EXTERIOR.
<br />TOTAL FIXTURE UNITS 40
<br />WATER SUPPLY FIXTURE UNITS- KITCHEN
<br />MARK
<br />DESCRIPTION
<br />MARK
<br />QUANTITY
<br />FIXTURE
<br />UNIT
<br />TOTAL NO. OF
<br />FIXTURE
<br />WC
<br />WATER CLOSET
<br />DORA CHAMPION WATER CLOSET
<br />HANDICAP 17"HIGH
<br />128 GAL / FLUSH,
<br />UNITAND INSTALLATION SHALL COMPLY WITH ADA AND TITLE 24.
<br />LAV
<br />EXISTING LAVATORY
<br />LAV
<br />LAVATORY
<br />S-1
<br />JOHN BOOS -31318244-21318
<br />-
<br />-
<br />S-1
<br />3 COMP. SINK
<br />PREP. SINK S.S. FREE STANDING SINK
<br />1
<br />2
<br />2
<br />S-2
<br />PREP SINK
<br />WCO
<br />1
<br />2
<br />2
<br />S-3
<br />HAND WASH SINK
<br />TANKLESS WATER HEATER
<br />2
<br />2
<br />4
<br />MS -1
<br />MOP SINK
<br />FS -1
<br />1
<br />2
<br />2
<br />MS -1
<br />FLORESTONE MSR -2424
<br />MOP SINK
<br />24"X24"X12" DEEP SINK. HOT AND COLD WATER FAUCET
<br />WITH 4" CENTER DRAIN OPENING
<br />FD -1
<br />ZURIN Z -415 -NH -P
<br />TOTAL FIXTURE UNITS 10
<br />34 UNIT FIXTURES = 22 GPM. PER CPC TABLE CHART A-5
<br />1 1/2" WATER LINE IS O.K.
<br />BRIEDERT T�
<br />"L" CAP
<br />FLASHING
<br />BLOCKING
<br />11 FLUE DUCT DETAIL
<br />COLLAR WITH
<br />3AND AT TOP
<br />ROOF
<br />ET ROCK
<br />N.T.S.
<br />1. DRAWINGS INDICATE DIAGRAMMATICALLY THE ARRANGEMENT OF PRINCIPLE APPARATUS, PIPING AND
<br />OTHER MATERIAL. FOLLOW DRAWINGS AS CLOSELY AS POSSIBLE, IN ORDER TO ACHIEVE A NEAT
<br />TO ACHIEVE ARRANGEMENT OF PIPING, AND EQUIPMENT WHILE STILL OVERCOMING OBSERVATION.
<br />2. PIPES (HW,CW,DRAIN) UNDER LAVATORY FOR THE PHYSICALLY HANDICAPPED SHALL BE INSULATED
<br />3. ALL PLUMBING VENTS SHALL TERMINATE NOT LESS THAN 10' FROM ANY OUTSIDE AIR INTAKE.
<br />4. DRAIN, WASTE, AND VENT PIPE SHALL BE ABS.
<br />5. WATER PIPES SHALL BE TYPE L COPPER, ASTM B88. COPPER PIPE BELOW GRADE SHALL
<br />HAVE PROTECTIVE COATING OF POLYETHYLENE.
<br />6. GAS PIPE SHALL BE SCHEDULE 40 BLACK STEEL, ASTM A120. GAS PIPING BELOW GROUND SHALL
<br />HAVE PROTECTIVE COATING WRAPPED MATERIAL BY MANUFACTURE. GAS
<br />PIPING SHALL BE BARRIED MINIMUM DEPTH OF 24" BELOW GROUND, ABOVE GROUND AT
<br />EQUIPMENT HORIZONTAL GAS PIPING SHALL BE SUPPORTED EVERY 6 FEET.
<br />7. ALL EQUIPMENT SERVED WITH GAS SHALL HAVE A SHUT-OFF VALVE AND FLEXIBLE CONNECTION AT UNIT.
<br />8. ROUTE 3/4" GALVANIZED OR COPPER PIPE DISCHARGE OF P & T RELIEF VALVES FROM WATER
<br />HEATER TO EXTERIOR OF BUILDING. STUB PIPING +6" ABOVE FINISH GRADE AND ELBOW DOWN.
<br />9. ROUTE 3/4" CU PIPE FOR CONDENSATE DRAIN FROM AC UNITS TO OUTSIDE @+6" A.F.F. W/ ELBOW DN.
<br />OR TO ROOF DRAIN
<br />10. WATER CLOSET AND ASSOCIATED FLUSHOMETER VALVES SHALL USE NO MORE THAN
<br />1.6 GAL. PER FLUSH & SHALL MEET PERFORMANCE STANDARD ESTABLISHED BY THE AMERICAN
<br />NATIONAL STANDARDS INSTITUTE STANDARD At 12-19-2. H&S CODE SECTION 17921.3(b).
<br />11. URINALS AND ASSOCIATED FLUSHOMETER VALVES SHALL USE NO MORE THAN 1.0 GAL.
<br />PER FLUSH & SHALL MEET PERFORMANCE STANDARD ESTABLISHED BY THE AMERICAN NATIONAL
<br />STANDARDS INSTITUTE STANDARD Al 12.19.2 H&S CODE SECTION 17921.3(b)
<br />12. ALL HOSE BIBB SHALL HAVE BACKFLOW PREVENTOR.
<br />13. PROVIDE MIN. OF 1/4"IFT. SLOPE AT ALL WASTE PIPING.
<br />14. SEE PLUMBING FIXTURE SCHEDULE FOR PLUMBING FIXTURE TYPE.
<br />15. ALL WATER PIPING IS IN ATTIC SPACE U.O.N. FOR UNDERGROUND PIPING.
<br />16. ALL PLUMBING SHALL MEET 2019 C.P.C.
<br />5 GENERAL NOTES N.T.S.
<br />FIXTURE CONNECTION SIZE
<br />FIXTURE SYM WASTE TRAP VENT COLD WATER HOT WATER
<br />BRANCH OUTLET BRANCH OUTLET BRANCH OUTLET
<br />WATER CLOSET WC 4" 4" - - - 314" 314" - -
<br />LAVATORY, SINK LAV 2" 2" - 1 1/2" 1 1/2" 3/4" 1/2" 3/4" 1/2"
<br />3 COMPARTMENT SIN S-1 2" 2" 1 1/2" - - 3/4" 1/2" 3/4" 112"
<br />FLOOR SINK/ F.D. FS 2" 1 2" - 1 1/2" 1 1/2" - - - -
<br />MOP SINK MS 2" 2" - 1 1/2" 1 1/2" 3/4" 1/2" 1/2" 112"
<br />PREP. SINK S-2 2" 2" 1 1/2" - - 3/4" 1/2" 314" 1/2"
<br />BRANCH SIZE
<br />MAXIMUM FIXTURE UNITS
<br />1/2"
<br />MARK
<br />MAKE & MODEL
<br />DESCRIPTION
<br />REMARKS
<br />WC
<br />EXISITING WATER CLOSET
<br />DORA CHAMPION WATER CLOSET
<br />HANDICAP 17"HIGH
<br />128 GAL / FLUSH,
<br />UNITAND INSTALLATION SHALL COMPLY WITH ADA AND TITLE 24.
<br />LAV
<br />EXISTING LAVATORY
<br />LAVATORY
<br />HANDICAP ACCESSIBLE
<br />FAUCET TO HAVE FLOW RATE OF .40 GALLON PER MINUTE
<br />S-1
<br />JOHN BOOS -31318244-21318
<br />3 COMPARTMENTS
<br />S.S. FREE STANDING SINK
<br />HOT AND COLD WATER FAUCET. 18" DRAIN BORAD
<br />(2 FAUCETS) PRE RINSE UNIT, SWING NOZZLE
<br />S-2
<br />JOHN BOOS- 1 B244-1 D24R
<br />PREP. SINK S.S. FREE STANDING SINK
<br />HOT AND COLD WATER FAUCET. 24" DRAIN BORAD
<br />S-3
<br />EAGLE HSA -10 -F -DS
<br />HAND SINK
<br />S.S. WALL MOUNT
<br />HOT AND COLD WATER FAUCET.
<br />WCO
<br />ZURN Z-1445-4
<br />WALL CLEAN OUT
<br />WALL CLEAN OUT W/ S.S. COVER
<br />WH -1
<br />RINNAI - CU -199
<br />TANKLESS WATER HEATER
<br />GAS WATER HEATER -200,000 BTU
<br />-C.O.T.G.
<br />ZURN Z-14060-15
<br />CLEAN OUT TO GRADE
<br />FS -1
<br />ZURIN NO. Z -1901 -NH -2,
<br />FLOOR SINK
<br />CAST IRON, ACID RESISTING ENAMELED, CAST IRON 1/2 GRATE, DOME STRAINER
<br />SEEPAGE FLANGE AND P -TRAP
<br />MS -1
<br />FLORESTONE MSR -2424
<br />MOP SINK
<br />24"X24"X12" DEEP SINK. HOT AND COLD WATER FAUCET
<br />WITH 4" CENTER DRAIN OPENING
<br />FD -1
<br />ZURIN Z -415 -NH -P
<br />FLOOR DRAIN
<br />CAST IRON, WITH ROUND POLISHED NICKLE BRONZE TOP, FLASHING COLLAR, TRAP PRIMER CONNECTION AND P -TRAP.
<br />TP
<br />P.P.P. NO P2
<br />TRAP PRIMER
<br />P.P.P. NO. P-2, COPPER BODY, ADJUSTABLE, WITH 1/2" COPPER TYPE "L" PIPE TO RECEPTOR.
<br />MV -1
<br />SYMMONS NO. 5 -120 -NI
<br />MIXING VALVE
<br />THERMOSTATIC CONTROLLER COMPLETE WITH INTEGRAL CHECK STOPS AND NICKLE PLATING.
<br />WATERINSURICE
<br />FILTER
<br />SINGLE -12000
<br />EVERPURE EV9324-01
<br />WATRE FILTER
<br />ET -1
<br />WILKINS NO. WXTP-12
<br />EXPANSION TANK
<br />SUSPENDED, 4 GALLON, DIAPHRAM TYPE, PRE -PRESSURED WITH WELDED EXTERIOR. BUTYL DIAPHRAM AND
<br />EPDXY COATED EXTERIOR.
<br />PUMP
<br />B & G SERIES 100
<br />CIRCULATING PUMP
<br />INLINE TYPE, ALL BRONZE, 5 G.P.M. AT 8 FEET OF HEAD, 1/2 H.P., 120 VOLT, 1 PHASE, 1750 RPM ( TIME CLOCK BY ELECTRICAL)
<br />WHA
<br />P.P.P. MODEL SC
<br />WATER HAMMER
<br />ARRESTOR
<br />P.P.P. MODEL SC, COPPER BODY 9 SIZED AND INSTALLED PER MANUFACTURER RECOMMENDATIONS).
<br />1. DRAWINGS INDICATE DIAGRAMMATICALLY THE ARRANGEMENT OF PRINCIPLE APPARATUS, PIPING AND
<br />OTHER MATERIAL. FOLLOW DRAWINGS AS CLOSELY AS POSSIBLE, IN ORDER TO ACHIEVE A NEAT
<br />TO ACHIEVE ARRANGEMENT OF PIPING, AND EQUIPMENT WHILE STILL OVERCOMING OBSERVATION.
<br />2. PIPES (HW,CW,DRAIN) UNDER LAVATORY FOR THE PHYSICALLY HANDICAPPED SHALL BE INSULATED
<br />3. ALL PLUMBING VENTS SHALL TERMINATE NOT LESS THAN 10' FROM ANY OUTSIDE AIR INTAKE.
<br />4. DRAIN, WASTE, AND VENT PIPE SHALL BE ABS.
<br />5. WATER PIPES SHALL BE TYPE L COPPER, ASTM B88. COPPER PIPE BELOW GRADE SHALL
<br />HAVE PROTECTIVE COATING OF POLYETHYLENE.
<br />6. GAS PIPE SHALL BE SCHEDULE 40 BLACK STEEL, ASTM A120. GAS PIPING BELOW GROUND SHALL
<br />HAVE PROTECTIVE COATING WRAPPED MATERIAL BY MANUFACTURE. GAS
<br />PIPING SHALL BE BARRIED MINIMUM DEPTH OF 24" BELOW GROUND, ABOVE GROUND AT
<br />EQUIPMENT HORIZONTAL GAS PIPING SHALL BE SUPPORTED EVERY 6 FEET.
<br />7. ALL EQUIPMENT SERVED WITH GAS SHALL HAVE A SHUT-OFF VALVE AND FLEXIBLE CONNECTION AT UNIT.
<br />8. ROUTE 3/4" GALVANIZED OR COPPER PIPE DISCHARGE OF P & T RELIEF VALVES FROM WATER
<br />HEATER TO EXTERIOR OF BUILDING. STUB PIPING +6" ABOVE FINISH GRADE AND ELBOW DOWN.
<br />9. ROUTE 3/4" CU PIPE FOR CONDENSATE DRAIN FROM AC UNITS TO OUTSIDE @+6" A.F.F. W/ ELBOW DN.
<br />OR TO ROOF DRAIN
<br />10. WATER CLOSET AND ASSOCIATED FLUSHOMETER VALVES SHALL USE NO MORE THAN
<br />1.6 GAL. PER FLUSH & SHALL MEET PERFORMANCE STANDARD ESTABLISHED BY THE AMERICAN
<br />NATIONAL STANDARDS INSTITUTE STANDARD At 12-19-2. H&S CODE SECTION 17921.3(b).
<br />11. URINALS AND ASSOCIATED FLUSHOMETER VALVES SHALL USE NO MORE THAN 1.0 GAL.
<br />PER FLUSH & SHALL MEET PERFORMANCE STANDARD ESTABLISHED BY THE AMERICAN NATIONAL
<br />STANDARDS INSTITUTE STANDARD Al 12.19.2 H&S CODE SECTION 17921.3(b)
<br />12. ALL HOSE BIBB SHALL HAVE BACKFLOW PREVENTOR.
<br />13. PROVIDE MIN. OF 1/4"IFT. SLOPE AT ALL WASTE PIPING.
<br />14. SEE PLUMBING FIXTURE SCHEDULE FOR PLUMBING FIXTURE TYPE.
<br />15. ALL WATER PIPING IS IN ATTIC SPACE U.O.N. FOR UNDERGROUND PIPING.
<br />16. ALL PLUMBING SHALL MEET 2019 C.P.C.
<br />5 GENERAL NOTES N.T.S.
<br />FIXTURE CONNECTION SIZE
<br />FIXTURE SYM WASTE TRAP VENT COLD WATER HOT WATER
<br />BRANCH OUTLET BRANCH OUTLET BRANCH OUTLET
<br />WATER CLOSET WC 4" 4" - - - 314" 314" - -
<br />LAVATORY, SINK LAV 2" 2" - 1 1/2" 1 1/2" 3/4" 1/2" 3/4" 1/2"
<br />3 COMPARTMENT SIN S-1 2" 2" 1 1/2" - - 3/4" 1/2" 3/4" 112"
<br />FLOOR SINK/ F.D. FS 2" 1 2" - 1 1/2" 1 1/2" - - - -
<br />MOP SINK MS 2" 2" - 1 1/2" 1 1/2" 3/4" 1/2" 1/2" 112"
<br />PREP. SINK S-2 2" 2" 1 1/2" - - 3/4" 1/2" 314" 1/2"
<br />BRANCH SIZE
<br />MAXIMUM FIXTURE UNITS
<br />1/2"
<br />3
<br />3/4"
<br />11
<br />11.
<br />25
<br />1-1/4"
<br />52
<br />1-1/2"
<br />117
<br />200 MBH
<br />OT STEAM TABLE
<br />61 FIXTURE SCHEDULES
<br />7
<br />GAS CALCULATION
<br />DESCRIPTION
<br />LOAD
<br />OA GAS BURNER
<br />128 MBH
<br />O CHARBROILER
<br />60 MBH
<br />OC FRYER
<br />100 MBH X 2 = 200 MBH
<br />O GRIDDLE
<br />134 MBH
<br />OG WH -1
<br />200 MBH
<br />OT STEAM TABLE
<br />14 MBH
<br />B� BAKERY OVEN
<br />300 MBH
<br />TOTAL GAS DEMAND
<br />1036 MBH = 1036 CFH
<br />TOTAL DEVELOPED PIPE LENGTH OF 150'
<br />PER C.P.C. TABLE 1216.2(1) USE 2 112" GAS
<br />GAS DEMAND
<br />CONCRETE SURFACE OR FLOOR
<br />COVERING AS REQUIRED
<br />CLEANOUT COVER
<br />CSK SCREW
<br />CLEANOUT PLUG
<br />FINISHED FLOOR
<br />CAULKING FI
<br />WROUGHT
<br />CLEVIS HI
<br />SEE SPEC:
<br />FOR TYPE
<br />1
<br />2
<br />3
<br />GAI
<br />1/2"
<br />BIB
<br />PIPE HANGER
<br />SCHEDULE
<br />PIPE SIZE HANGER PDD I
<br />BOLT
<br />1/2' THRU 3/4'
<br />1/4'
<br />1/4'
<br />1' THRU 1-1/2'
<br />3/8'
<br />3/8'
<br />2' THRU 2-1/2'
<br />3/8'
<br />1/2'
<br />3'
<br />1/2'
<br />1/2'
<br />TOP CORD OF TRU:
<br />3/8' DIA ALL TRE
<br />W/ DBL NUT AT P
<br />2'X2'Xl/8' ANGLE
<br />CLIP
<br />HANGER ROD —
<br />SEE SCHEDULE
<br />FOR SIZE
<br />ADJUSTABLE
<br />BAND HANGER
<br />SEE SPECS
<br />FOR TYPE
<br />PIPE HANGER DETAIL
<br />FLUE VENT
<br />THRU ROOF
<br />INSTANT TANKLESS
<br />WATER HEATER
<br />THERMAL EXPANSION TANK REQUIRED
<br />WHEN BUILDING SUPPLY PRESSURE
<br />IS GREATER THAN RELIEF VALVE
<br />PRESSURE SETTING AS PER U.P.C.
<br />SEC. 608.3
<br />GAS WATER HEATER DETAIL
<br />MAY EXTEND AS
<br />WASTE OR VENT
<br />FOR WALL CONST.
<br />REF. ARCH. DWGS.
<br />C.I. CLEANOUT TEE
<br />FLOOR LINE
<br />D D D D
<br />D D D D D
<br />WALL CLEANOUT DETAIL
<br />VENT PIPE
<br />SEE PLAN
<br />FOR SIZE
<br />ALL FLASHING SHALL BE PER
<br />LATEST SMACNA STANDARDS
<br />8" SKIRT
<br />CLEANOUT
<br />PLUG
<br />COUNTERSUNK
<br />SCREW
<br />POLISHED S.S.
<br />ACCESS COVER
<br />118" BEND AND END
<br />OF LINE CLEANOUT
<br />WASTE LINE
<br />LENGTH TO SUIT
<br />hiT/_M04401m
<br />COUNTERFLASHING SLEEVE
<br />MASTIC
<br />N.T.S.
<br />N.T.S.
<br />N.T.S.
<br />SEAMLESS LEAD FLASHING
<br />W/ 41-8. SHEETLEAD COUNTER
<br />FLASHING ®LOWSIDE.
<br />PLUMBING FIXTUF�E SCHEDULE 18 I FLOOR CLEAN OUT "TS 14 � VENT THRU ROOF DETAIL N.T.S. I
<br />2 3 0 1 Coffee Road #B ♦ Modesto, CA 95355
<br />Phone: 209 - 408-0674 ♦ edmond@etjarchitect.com
<br />ARCHITECT:
<br />THE DRAWINGS, SPECIFICATIONS, DESIGN AND IDEAS
<br />DESCRIBED HEREIN SHALL REMAIN THE PROPERTY OF
<br />THE ARCHITECT AND NO PART THEREOF CAN BE COPIED,
<br />DUPLICATED, DISCLOSED TO OTHERS OR USED IN
<br />CONNECTION WTH ANY WORK OR PROJECT OTHER THAN
<br />THE SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN
<br />PREPARED AND DEVELOPED WITHOUT EXPRESS WRITTEN
<br />PERMISSION OF THE ARCHITECT.
<br />EDMOND T. JACOBS ARCHITECT COPYRIGHT 2022
<br />CONSULTANT
<br />PROJECT ADDRESS:
<br />MANTECA FOOD
<br />TENANT IMPROVEMENT
<br />KITCHEN
<br />& MEAT AREA
<br />REMODEL
<br />441 N. MAIN ST.
<br />MANTECA, CA 95336
<br />CLIENT:
<br />MR. EMAD MOHSEN
<br />447 N. MAIN STREET
<br />MANTECA, CA 95336
<br />DATE:
<br />MARCH 11, 2022
<br />DRAWN:
<br />ETJ
<br />FILE:
<br />331 -21 -P1 -PLUMBING
<br />PROJECT NO:
<br />329-21
<br />PERMIT NO
<br />DESCRIPTION:
<br />PLUMBING NOTES /
<br />DETAILS AND
<br />SCHEDULE
<br />
|