S A N J O A Q U I N Environmental Health Department <br /> AMENDED <br /> 2/27/2025 <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> YRC INC 1 1535 E Pescadero AVE Tracy February 26 2025 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> CORRECTIVE ACTION: Submit updated scope of work and certifications for all work that have been conducted to EHD <br /> so an updated approval permit may be sent. <br /> This is(Minor)Violation. <br /> Overall Inspection Comments: <br /> Routine UST Inspection <br /> An inspection report was provided to the facility operator on the day of inspection, February 26, 2025. The report <br /> was amended February 27, 2025 to add an additional note in the NOTE section of the Overall Inspection <br /> Comments, no violations were added, amended or removed. This amended report replaces the initial report and <br /> does not affect return to compliance date of March 28, 2025. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by March 28, 2025. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of <br /> having them sign. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($172). To schedule an <br /> appointment, please call (209)468-3420. <br /> ITEM#52 CONTINUED <br /> REGULATION GUIDANCE:All underground storage tanks shall be equipped with an overfill prevention system <br /> that does not allow for manual override and meets one of the following requirements: <br /> 1. Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or triggering an <br /> audible and visual alarm; or <br /> 2. Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the restriction occurs <br /> when the tank is filled to no more than 95 percent of capacity; and activate an audible alarm at least five minutes <br /> before the tank overfills; or <br /> 3. Provide positive shut-off of flow to the tank when the tank is filled to no more than 95 percent of capacity; or, <br /> 4. Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the tank are <br /> exposed to product due to overfilling. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to install an <br /> approved overfill prevention system. Replacement of a mechanical flapper valve requires a permit and inspection <br /> by the EHD. If an external audio/visual alarm is replaced, provide a copy of the service receipt to the EHD. If an <br /> approved overfill prevention system can't be installed immediately, there is a possibility that the soap, used oil <br /> (-002, tank#2), used oil (-003, tank#6), and waste diesel UST system may be red tagged to prevent fuel inputs. <br /> FA0003854 PR0232495 SCO01 02/26/2025 <br /> EHD Rev.1 210 6/2 02 1 Page 7 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />