®Fuel-powered(gas or liquid) Move power cords/pressurized hoses to protect from damage during tool/equipment use. <br /> ❑Pneumatic • For spark/heat generating tool/equipment,have fire extinguisher available,remove combustible/flammable <br /> ❑Hydraulic materials,or use other means to control fire hazard(e.g.fire watch,fireproof blanket). <br /> El Gunpowder-actuated • Use safe lifting practices and/or lift aids for moving heavy portable equipment,and use safe operating <br /> f Hazards of Power Tools and procedures to protect from acute strains/sprains,overexertion,and cumulative trauma injuries. <br /> Powered Equipment: I • Implement safe work practices for compressed air,pressurized systems(pneumatic/hydraulic),stored energy. <br /> ®Eye/hand/body injury <br /> ®Additional requirements for power tools: <br /> i ®Point-of-operation hazards • Use vise/clamp/work bench or other means to hold/secure a portable/moveable work piece. <br /> i • Don't carry electrical tools/equipment by the power cord;don't carry pneumatic tools by hoses. <br /> ®Pinch points,moving parts • Disconnect tool/equipment from power source before changing bits,blades or making adjustments. <br /> ❑Line of-fire hazards,struck by i ❑Additional requirements for fixed powered equipment: <br /> 1 ®Fire/explosion,ignition sources • Implement lockout/tagout controls for repairs/adjustments/tooling changes. <br /> 'I ®Burns from hot surfaces,steam • Equip pneumatic hoses with whip checks;ensure factory fittings are used for high-pressure hose connections. <br /> ❑Noise <br /> f <br /> ❑Inhalation/atmospheric hazards ❑For climbing/fall hazards associated with large equipment,see D.4."Fall Hazards." <br /> i � <br /> ❑Working at heights,falls ®For electrical hazards,see D.10."Electrical Work Tasks." <br /> ' ❑Overhead obstruction(s) f ❑For ground surface penetration,see D.11."Utility-Related Hazards." <br /> El Musculoskeletalhgzards 1 ®For fuel-safety practices,see D.14."Commercial Chemical Products." <br /> El Potential(stored)energy ; ❑For air monitoring of atmospheric hazards,see Part E,"Air Monitoring,Worker Exposure Monitoring." <br /> I <br /> ❑Illumination j <br /> WELDING,CUTTING,HOT WORK ❑General safe work practices for operators of welding equipment: <br /> ❑Arc-welding(electrical arc) • Hot work permit system shall be implemented. <br /> ❑Gas-welding/cutting(fuel gases) • Operator properly protected(eye protection,clothing,apron,etc.). <br /> Hazards: • Fire hazard controls(watcher,fire extinguisher,water,remove combustibles from work area). <br /> UV/IR)ight-eye/skin burns ' • Protect nearby personnel from hazardous UV,IR light(shielding,curtain);see D.16."Radiation Hazards." <br /> hot-work hazards/fire ®For welding gas cylinders,secure them upright with caps on when stored or not in use;protect cylinders from <br /> -toxic metal welding fumes damage;NEVER secure gas cylinders to metal welding bench used for electrical arc welding; <br /> compressed gases(physical see D.14."Commercial Chemical Products." <br /> j hazards,fire,oxygen deficiency) I ❑For arc welding,follow electrical safe work practices;see D.10."Electrical Work Tasks." <br /> electrical shock <br /> ❑For inhalation hazards from welding fumes(toxic metals)and gases(asphyxiant,flammable),see D.14. <br /> "Commercial Chemical Products." <br /> ® PORTABLE ELECTRIC GENERATOR j ®Follow general safe work practices for Powered Tools&Equipment(above),and as follows: <br /> Hazards: • Use in accordance with manufacturer's instructions,including instructions for grounding the generator. <br /> Electrical shock I • Keep generator and work area dry. <br /> Carbon monoxide inhalation • Never use indoors,or near building air intake vents due to carbon monoxide hazard. <br /> hazard • Provide for ventilation and/or air monitoring where hazardous accumulation of exhaust emissions is possible. <br /> Fuel-related fire hazard ! • Use hearing protection in close proximity to operating generator(where noise level exceeds 85 dBA). <br /> Injury from mechanical or lifting i • Use power cords/extension cords specified by instructions. <br /> hazard • Use ground-fault circuit interrupters(GFCIs)in accordance with manufacturer's instructions;see D.10. <br /> Burns from hot surfaces "Electrical Work Tasks." <br /> • Shut down equipment before refueling;see safe practices for flammable/combustible liquids in D.14. <br /> "Commercial Chemical Products." <br /> PNEUMATIC/HYDRAULIC HAZARDS ❑Never direct outlet nozzle toward body;use guards,restraints,engineering controls as appropriate. <br /> ❑Air compressor ❑Never use compressed air for cleaning clothes you are wearing. <br /> ❑Compressed air system ❑If compressed air is used for cleaning,restrict pressure to 30 psi or below,equip nozzle with chip guard. <br /> ❑High-pressure liquid ❑Use PPE for eye(goggles or face shield)/hand/head/hearing/skin protection,as appropriate for the hazard. <br /> I <br /> ❑Ensure tank,hoses,fittings are in good repair using factory fittings,equipped with whip-checks. <br /> ❑Pressurized steam <br /> (For compressed gas cylinders,see ' ❑If pressure relief device poses a hazard to workers,reconfigure or shield device or restrict access by workers. <br /> D.14."Commercial Chemical <br /> Products") <br /> ❑ PORTABLE HEATER 1 ❑Follow general safety practices for Operation of Equipment/Machinery(above),and as follows: <br /> ❑electric • Keep heater dry and locate heater on level surface away from high traffic areas to prevent tipping. <br /> ❑fuel-powered • Never use fuel-powered heaters indoors,or near air intake vents,due to carbon monoxide hazard. <br /> Hazards: • Provide ventilation and/or air monitoring where hazardous accumulation of exhaust emissions is possible. <br /> Shock(electrical) • Keep combustible materials at least 3 feet from hot surfaces. <br /> 1 - Carbon monoxide emissions and <br /> • Plug electric heaters directly into wall outlet(don't use extension cord or power strip). <br /> fuel-related fire hazards(fueled) • For electric heaters,see D.10.,"Electrical Work Tasks." <br /> Fires/burns from hot surfaces. <br /> • Shut down fuel-powered equipment before refueling;see safe practices for flammable/combustible liquids <br /> and/or compressed gases in D.14."Commercial Chemical Products." <br /> Project/Task Name:TR0712/Replacement of Monitoring Wells THA ver.4.0 <br /> Geosyntec THA Date:6/26/2025 Page 10 <br /> consultants <br />