Laserfiche WebLink
SAN J0AQUIN <br />COUNTY <br />AMENDED Environmental Health Department <br />8/13/2025 <br />Aboveground Petroleum Storage Act Program Inspection Report <br />Facility Name: <br />Facility Address: <br />114749 <br />Date: <br />lAugust <br />3 b's truck & auto laza <br />N Thornton RD Lodi <br />05 2025 <br />15 <br />Code of Fed Regulations 112.7(a)(3)(i) 4010041 - SPCC Plan addresses the type of oil and storage capacity for all <br />fixed and portable containers <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to address the type of oil and <br />storage capacity for each fixed container, <br />- The SPCC plan does not address the 500 gallon tank of new motor oil, it is located inside the truck repair shop. <br />REGULATION GUIDANCE: The SPCC plan shall include: (i) The type of oil in each fixed container and its storage <br />capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each container or <br />provide an estimate of the potential number of mobile or portable containers, the types of oil, and anticipated storage <br />capacities. <br />CORRECTIVE ACTION: The SPCC Plan shall properly address the type and storage capacity of all fixed and portable <br />and/or mobile containers, as required. Include in the plans the 500 gallon tank of new motor oil. Submit proof of <br />correction to the EHD. <br />This is a Repeat (Class 2) Violation. <br />16 <br />Code of Fed Regulations 112.7(a)(3), 25270.4.5(a) 4010015 - SPCC contains an adequate facility diagram <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to include an adequate facility <br />diagram <br />- The facility diagram does not include the location of the 500 gallon tank of motor oil, it is located inside the truck repair <br />shop. <br />REGULATION GUIDANCE: (3) Describe in your Plan the physical layout of the facility and include a facility diagram, <br />which must mark the location and contents of each fixed oil storage container and the storage area where mobile or <br />portable containers are located. The facility diagram must identify the location of and mark as "exempt" underground <br />tanks that are otherwise exempted from the requirements of this part under § 112.1(d)(4). The facility diagram must also <br />include all transfer stations and connecting pipes, including intra -facility gathering lines that are otherwise exempted from <br />the requirements of this part under § 112.1(d)(11). <br />CORRECTIVE ACTION: Ensure that the SPCC plan includes a complete facility diagram. Revise facility diagram to <br />include the 500 gallon tank of motor oil. Provide proof of correction to the EHD. <br />This is a (Minor) Violation. <br />EHD - CUPA Inspection Report IS02 <br />Page 5 of 10 FA0000482 PR0515788 4533103 8/13/2025 <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />