My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2026 8:57:06 AM
Creation date
1/15/2026 7:41:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0231819
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003732
FACILITY_NAME
GAVINKO PETROLEUM*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\bmascaro
Supplemental fields
Site Address
7700 MORELAND ST STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN AMENDED Environmental Health Department <br /> COUNTY— 1/8/2026 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GAVINKO PETROLEUM* 17700 MORELAND ST, STOCKTON TIOctober 16, 2025 <br /> 56 2716(a-e) 2030013- DO inspections completed at least every 30 days and meet all requirements (TCR 12) <br /> OBSERVATION: The following issues were discovered while reviewing the DO inspection reports: <br /> -> The 7/9/2025 DO inspection Report did not include follow up for the following alarms from 6/13/2025, no work orders <br /> were found. <br /> L14: Diesel STP annular- Fuel Alarm <br /> S1: 87 Line Vacuum <br /> S3: 91 line- No Vacuum <br /> S3: 91 line- Communication <br /> S5: Diesel Vent- High Liquid Alarm <br /> -> The 8/8/2025 DO inspection Report did not include follow up for the following alarm, no work orders were found. <br /> 7/29/2025 1-2: 87 Fill - Fuel Alarm <br /> -> The 10/8/2025 DO inspection Report did not include follow up for the alarm from 9/30/2025 L16: Dispenser 1/2 <br /> Annular Space - Fuel Alarm, no work orders were found. <br /> -Section 11 was left blank on the 5/9/25 report <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall review the alarm history since the <br /> previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of the <br /> required information on the reports. <br /> This is a Repeat(Class 2)Violation. <br /> 58 2715(c)(3), 2715(c)(4) 2010015 - Copies of Facility Employee Training Certificates maintained <br /> OBSERVATION: The Facility Employee Training Certificate was not available for review at the time of inspection. <br /> REGULATION GUIDANCE: All site employees must be trained prior to taking responsibility as a facility employee if after <br /> October 1, 2018, or within 30 days of hire if prior to October 1, 2018. The Facility Employee Training Certificate shall <br /> contain accurate information for all employees trained. <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This is a Repeat(Class 2)Violation. <br /> 72 2712 2030039- Compliance with all operating permit requirements <br /> OBSERVATION: The s3 &s6 sensors were replaced on 6/13/2025 and a permit was not obtained from the EHD. <br /> -A sensor replacement that is like for like requires a "UST Retrofit- No Fee Permit", where certain conditions need to be <br /> met. For this replacement that was done on 6/13/2025, the conditions were not met. <br /> REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed, trained, and certified contractor pursuant to the EHD's policy and a permit obtained <br /> within one business day from the EHD. All other repairs must have a permit submitted to and approved by the EHD prior <br /> to beginning work. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD for the like for like replacement of the s3 &s6 <br /> sensors. A"Failure to Obtain a Permit" penalty applies. <br /> This is a Repeat(Class 2)Violation. <br /> EHD-CUPA Inspection Report IS03 Page 6 of 7 FA0003732 PR0231819 4565085 1/8/2026 <br /> CP22-UST FULL g <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.