My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2026
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOFF
>
1515
>
2200 - Hazardous Waste Program
>
PR0538579
>
COMPLIANCE INFO_2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/3/2026 3:26:40 PM
Creation date
2/9/2026 2:26:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2026
RECORD_ID
PR0538579
PE
2229 - GEN 50<250 TONS PERMIT
FACILITY_ID
FA0017929
FACILITY_NAME
SPEEDCO # 944
STREET_NUMBER
1515
STREET_NAME
HOFF
STREET_TYPE
DR
City
RIPON
Zip
95366
APN
24534026
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1515 HOFF DR RIPON 95366
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
O <br /> Hazardous Waste Tank System Assessment <br /> Love's/SpeedCo#944, Ripon,CA a ntea®g ro u p <br /> May 2024 <br /> D. Regulatory Requirement:Description of any internal and external pumps <br /> The diaphragm pump is connected to the OWS and another diaphragm pump is in the service <br /> pit that pumps directly into the tank. <br /> E. Regulatory Requirement:Sketch or drawing of tank including dimensions. <br /> See the sketch of the tank in Appendix A and the photos in Appendix B.The tank is <br /> approximately 168 inches long, 95 inches wide,and 115 inches tall. <br /> 1.3 Regulatory Requirement:Documented age of the tank system(if tank was previously used), if <br /> available, (otherwise, an estimate of the age) <br /> Unknown.The tank is estimated to be 20 years old. <br /> 1.4 Regulatory Requirement:Description and evaluation of any leak detection equipment <br /> The tank is elevated to visually observe spills. <br /> 1.5 Regulatory Requirement:Description and evaluation of any corrosion protection equipment, <br /> devices, or material <br /> The tank is painted blue and is in good condition. <br /> 1.6 Regulatory Requirement:Description and evaluation of any spill prevention or overfill equipment <br /> A clock-style liquid level gauge and overfill probe are mounted on the top of the tank. <br /> 1.7 Regulatory Requirement:Description and evaluation of secondary containment for the tank system <br /> (secondary containment must meet minimum standards as specified in sections 66264.192(k)(1)through <br /> (k)(3)and 66265.192(j)(1)through(j)(3))including applicable secondary containment for ancillary <br /> equipment as required in subsection 66265.193(f) <br /> The tank and its associated piping are provided secondary containment by the tank room floor <br /> and walls or by the service pit sump. <br /> 1.8 Regulatory Requirement:Hazardous characteristics of the waste(s)that have been or will be handled <br /> The tank contains used oil which is a Class III B liquid with a flash point >200°F. Tank <br /> hazardous waste generator labels are present on the tank. Generator information and log <br /> are filled out. A National Fire Protection Association (NFPA) fire warning label is not present <br /> on the tank. <br /> 1.9 Regulatory Requirement:Tank assessment-prior to placing anew tank system or component in <br /> use, an independent qualified installation inspector or an independent qualified,professional engineer, <br /> registered in California, either of whom is trained and experienced in the proper installation of tank <br /> systems,shall inspect the system or component for the presence of any of the following items and <br /> document in writing the results of the inspection: <br /> �I NOGENO <br /> ALLIANCE us.anteagroup.com <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.