My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3081
>
2900 - Site Mitigation Program
>
PR0541231
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2026 9:53:04 AM
Creation date
2/27/2026 9:19:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0541231
PE
2959 - DTSC LEAD AGENCY SITE
FACILITY_ID
FA0023619
FACILITY_NAME
FORMER QUALITY CLEANERS TRACY CORNERS SHOPPING CENTER
STREET_NUMBER
3081
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418041
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
Site Address
3081 N TRACY BLVD TRACY 95376
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
549
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
and historical documentation (Appendix E). An additional purpose is to obtain data sufficient to <br /> augment the existing Site conceptual model (CSM). <br /> 1.3 Site Characterization Objectives <br /> The proposed objectives of the characterization of soil, soil gas, and groundwater sampling are <br /> listed below. <br /> • Indoor air sampling as part of a vapor intrusion assessment of the Quality Cleaners and <br /> adjacent tenant suites, specifically, the Comcast store to the east and the Fred Loya <br /> Insurance office to the west, respectively. This task is necessary given that a December <br /> 2014 sub-slab soil gas sample contained 350 micrograms per cubic meter (µg/m3) of <br /> trichloroethene (TCE), a concentration that may, if vapor intrusion has occurred, exceed <br /> the DTSC's indoor air Commercial/Industrial Accelerated Response Action Level of 8 <br /> µg/m3 as promulgated in the DTSC's August 23, 2014 Human and Ecological Risk Office <br /> (HERO) Human Health Risk Assessment (HHRA)Note Number 5. <br /> • Sub-slab soil gas sampling beneath the Quality Cleaners as part of a vapor intrusion <br /> assessment of the Quality Cleaners. A single five-foot deep soil gas probe will also be <br /> installed beneath the dry cleaners suite to assess the vertical extent and attenuation of PCE <br /> and other potential volatile organic compounds (VOCs). A December 2014 sub-slab soil <br /> gas sample beneath the Quality Cleaners suite contained 3,300 µg/m3 of PCE and 350 <br /> µg/m3 of TCE and a groundwater sample southwest and proximate to the Quality Cleaners <br /> contained 30 micrograms per liter(µg/L) of PCE. <br /> • Shallow soil gas sampling from five-foot deep soil gas probes along the southern boundary <br /> of the Site to assess the potential for vapor intrusion related to the residential structures <br /> located approximately 100 feet south of the Quality Cleaners. Soil gas sampling from six <br /> soil gas probes installed along the alignment of an approximately 660-foot long sewer <br /> lateral associated with the Quality Cleaners to assess whether a significant release of PCE <br /> has occurred from the sewer lateral. <br /> • Installing and monitoring of groundwater monitoring wells in the presumed upgradient and <br /> downgradient locations relative to the Quality Cleaners to define the potential lateral extent <br /> of PCE and other VOCs in groundwater and to verify the groundwater flow direction. The <br /> vertical characterization will occur following the confirmation of the groundwater flow <br /> direction using continuously cored soil borings and the collection of grab groundwater <br /> samples from targeted strata. <br /> • The historical Documentation from 1991 noted a potential issue with a petroleum <br /> hydrocarbon release within the Site boundaries. The DTSC requested soil borings be <br /> advanced at a location southwest of the intersection of North Tracy Boulevard and Clover <br /> Road and from three additional locations within the Site. Based on the 1991 analysis of <br /> Sampling and Analysis Workplan <br /> Tracy Corners Shopping Center <br /> 3225 North Tracy Boulevard <br /> Tracy,California 95376 <br /> Partner Project Number SM14-129814 <br /> Docket Number HAS-VCA 14/15-108 <br /> August 15,2016 <br /> Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.