Universal Health & Safety Plan <br /> For use on all high-risk,industrial and HAZWOPER projects <br /> Department of Toxic Substances Control <br /> ❑X Combustible Gas Indicator(CGI) ■ Explosivity <br /> May be combined with individual or <br /> multi-gas detectors. <br /> ❑X Particulate Monitor ■ MIE Model PDM-3 mini-RAM ■ Aerosols, mist, dust, and fumes <br /> ❑X Noise Monitor ■ TSI Quest Edge Personal Noise ■ n/a <br /> Dosimeter <br /> ❑ j Personal Monitoring/Badges ■ n/a ■ n/a <br /> 2.9.2 Monitoring Procedures <br /> The monitoring procedures shown below are general guidelines for sampling activities. In general, readings are considered <br /> actionable if sustained readings are observed for 5 minutes or more or if intermittent peaks are seen in excess of 1 time the <br /> action level.A reading in excess of action level outlined below will require additional ventilation(natural or mechanical)for 30 <br /> minutes,followed by re-monitoring. <br /> Monitoring Procedures and Action Levels <br /> Parameter Zone Location and .. <br /> Monitoring <br /> ❑X Volatile Organic Breathing zone, continuously < 1 ppm ■ Continue monitoring, may continue work <br /> Compounds(VOCs) during tasks where exposure to in required PPE <br /> and Volatile VOCs and volatile hydrocarbons is 1-25 ppm ■ STOP WORK and notify PM. Investigate <br /> Hydrocarbons possible (sustained for the cause of elevated VOC <br /> (total by PID) 3 minutes) measurements and identify measures to <br /> reduce concentrations(cover impacted <br /> soils, ventilation, etc.).Work activities <br /> shall only continue once levels have <br /> decreased to or below 5 units above <br /> background. If levels continue above 5 <br /> units, only individuals who are medically <br /> qualified to wear respiratory protection <br /> are permitted to continue work activities <br /> with Project Manager approval. Don <br /> Level C PPE(organic vapor respirator <br /> cartridges), continue monitoring, and <br /> initiate continuous air monitoring for <br /> benzene. Colorimetric tube for Vinyl <br /> Chloride <br /> >25 ppm ■ Cease work, exit, and contact the Site <br /> (sustained for Safety Officer, Site Supervisor, and <br /> 3 minutes) Project Manager. <br /> 0 Benzene Breathing zone, continuously >0.25 ppm ■ Cease work, exit the area, and contact <br /> (by PID with benzene- where indicated by VOC readings the Site Safety Officer, Site Supervisor, <br /> specific separation tube) and Project Manager. <br /> 0 Vinyl Chloride(with Breathing zone continuously >0.25 ppm ■ Cease work, exit the area, and contact <br /> colorimetric tube) where indicate by VOC readings the Site Safety Officer, Site Supervisor, <br /> and Project Manager <br /> ❑ Hydrogen Sulfide Breathing zone, continuously <5 ppm ■ Continue work activities. Contact the <br /> (multi-gas detector or during tasks where exposure to Site Safety Officer to investigate the <br /> individual H2S meter) hydrogen sulfide is possible potential for contributing factors. <br /> ©AECOM Restricted <br /> Universal Heath and Safety Plan Template(S4(DSC)AM-209-FM-C) 8 <br /> Revision 12 September 9,2021 <br /> PRINTED COPIES ARE UNCONTROLLED.CONTROLLED COPY IS AVAILABLE ON COMPANY INTRANET. <br />