Laserfiche WebLink
PROGRAMMING - H5-ELEMENT Continued <br />NOTE: Turning off this function will disable “P5” and “P6”. <br />BQS <br />■■ <br />46819 043012 <br />Continued <br />12 <br />saa7. Press and release the upper hidden button once more. The display will read P5. <br />This will toggle the energy save mode from 140°F (60°C) or tank heater “OFF”. <br />(H5H) <br />(H5L) <br />8. Press and release the upper hidden button once more. The display will read P6. <br />This is the time delay from the last refill to the activation of energy save mode. <br />Range: 4 hours to 24 hours. <br />3. Press and release the upper hidden button once more. The display will show P2. <br />Display will now show the “SET” temperature (ex: 200). Press the (+) button to <br />increase the temperature set point, or the (-) button to decrease the set point. <br />Range: 60°F (15°C) to 210°F (99°) NOTE: Temp will skip to 212°F (100°C) on H5X. <br />4. After the Tank Temperature is entered, press and release the upper hidden button <br />once more. The display will read P3, then show the ready temperature set point. <br />Range: 2° to 20° below the “SET” temperature. <br />5. Press the (+) button to increase, or the (-) button to decrease the set point. <br />6. Press and release the upper hidden button once more. The display will read P4. <br />This screen will allow you to turn the “Auto” energy save mode ON/OFF. <br />2. The display will now show the model number. <br />5 Gallon High Voltage Unit (200-240V) <br />5 Gallon Low Voltage Unit (100-120V) ' \ , <br />Now scroll with the (+/-) buttons through the models listed above until the display MHH ■■■ HI ' <br />matches the model you are working with.IBS