My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2007
>
EP-07-301 thru EP-07-400
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2007_EP-07-301 thru EP-07-400_ - EP-07-349
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:47:06 AM
Creation date
12/30/2015 9:55:27 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-07-349
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2007\EP-07-301 thru EP-07-400
Year2
2007
Supplemental fields
Applicant
ZABIH ZACA
Contracts
CrossReference
Date Entered
11/16/2007
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
FROM CHRISMAN RD. ALONG THE S/S OF 11th ST.
Primary Parcel
Type (2)
Tags
Permits_Development
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
E. Completion <br /> Construction stakes shall be removed from the site of the work when no longer needed. — <br /> MEASUREMENT AND PAYMENT <br /> No measurement will be made. Full compensation for conforming to these requirements, <br /> including all the labor, materials, tools, equipment, incidentals and for doing all the work <br /> involved in construction staking necessary for completion of the work, as shown on the Contract <br /> Plans, as specified in the Standard Specifications, these special provisions and as directed by <br /> the Engineer, shall be considered as included in the prices paid for the various contract items of <br /> work involved and no additional compensation will be allowed. _ <br /> SECTION 01060 — DISRUPTION OF EXISTING FACILITIES <br /> A. General <br /> All disruptions to existing facilities shall be approved by the Engineer in writing and shall be for <br /> the shortest duration possible. <br /> B. Submittals <br /> As part of the requirements for submittal of progress schedules, Contractor is required to <br /> prepare and submit in accordance with Section 01300 a written plan detailing the plan of <br /> operation, traffic control, the materials, methods, schedule, equipment to be used, hours of — <br /> operation, number of workers, and type of work to be conducted within the time period allowed <br /> for the disruption to existing facilities. The plan including traffic control plan shall be submitted to <br /> the City and County for approval eight weeks prior to planned work. Coordinate all activities for _ <br /> the execution of the Work. Shutdowns shall not proceed without the review and approval of the <br /> Engineer. No time extensions or damages will be considered for delays caused by failure of <br /> Contractor to plan, schedule and coordinate the Work. <br /> C. Water System Disruption <br /> The Contractor is cautioned that water and sewer main connections to the existing City system _ <br /> involve disruptions to existing facilities. Existing facilities must remain in service at all times <br /> except as provided herein. <br /> The Contractor shall coordinate shutdowns with City staff, providing a minimum of seventy-two <br /> (72) hours of prior notice. The Contractor shall schedule and coordinate the necessary shutdown <br /> of the existing facilities with the City of Tracy Utility Division, the shutdown shall be held to a _ <br /> minimum and the Contractor shall have all materials required for the work at the job site prior to <br /> requesting the shutdown. Contractor shall not operate any valves. All valve operation shall be <br /> conducted by the City of Tracy staff. <br /> This work includes connecting the new water main pipe to the existing City water main pipe <br /> where indicated on the plans. The newly installed facilities are to be isolated from the City <br /> system with AMES 3000 Double Check Detector Assembly, or equal, until bacteriologically _ <br /> acceptable. The Contractor shall designate the method and sequence of connecting to existing <br /> mains for the Engineer's approval to minimize contamination danger. Connections to existing <br /> Division III-19 NEI Phase II Water and Sewer <br /> July 2007 CIP Nos. 7468, 7589, 7590 <br />