Laserfiche WebLink
Area Traffic Control Devices," of the Standard Specifications and these special provisions. Messages displayed <br /> Portable changeable message sign shall be as specified on the plans and shall conform to Section 12-3.12 "P <br /> Changeable Message Si g P yed on the <br /> g Signs of the Standard Specification and"Maintaining Traffic"of these special provisions." "Portable <br /> A portable changeable message sign shall be placed in advance of the first warning sign for each stationary lane closure. <br /> A portable changeable message sign shall be placed before and during ramp closures. <br /> The contract lump sum price paid for portable changeable message signs <br /> all labor, materials, tools, equipment and incidentals and for doing all the work involved in furnishing, placing,8 gns shall include full compensation for furnishing <br /> maintaining repairing, transporting from location to location and removing place a specified in the Standard Specifications and these special provisions, as shownninethe plans able sand as irectmpl y the <br /> Engineer. in <br /> ed by the <br /> 10-1.14 TEMPORARY CRASH CUSHION MODULE <br /> This work shall consist of famishing, installing, and maintaining sand filled temporary <br /> groupings or arrays at each location shown on the plans, as specified in these special provisions or where designated b <br /> Engineer. The P ary crash cushion modules in <br /> grouping or array of sand filled modules shall form a complete sand filled temporary gn Y the <br /> conformance with the details shown on the plan and these special provisions. p <br /> Attention is directed to"Public Safeer P mry crash cushion in <br /> Whenever the work or the Contractor's ope�tion estabrlishes a fixed obstacle,,-Of these special lthe exposed <br /> protected with a sand filled temporary crash cushion. The sand filled temporary <br /> Opening the lanes adjacent to the fixed obstacle to public traffic. p axed obstacle shall be <br /> P ary crash cushion shall be in place prior to <br /> Sand filled temporary crash cushions shall be maintained in place at each location, including times when work <br /> s not <br /> actively in progress. Sand filled temporary p ary crash cushions may be removed during a work period for access to the lwork <br /> Provided that the exposed fixed obstacle is 4.6 m or more from a lane carrying <br /> is reset to protect the obstacle prior to the end of the work period in which the fixed obstacle was exposed. When required,as determined by the Engineer,sand filled temporary g public traffic and the temporary crash cushion <br /> At the Contractor's option,the modules for use in sand f led temporary crash shall be removed from the site of the work. <br /> nger <br /> Modules,Fitch Inertial Modules or TrafFix Sand Barrels manufactured aft March 3111997 orlequal: Energite III Inertial <br /> 1. Energite III and Fitch Inertial Modules, manufactured by Energy Absorption Systems, Inc., 35 East Wacker <br /> Suite 1100,Chicago,IL 60601: <br /> Drive, <br /> 1.1. Northern California: Traffic Control Service, Inc., 8585 Thys Court, Sacramento, CA 95828, telephone <br /> (800)884-8274,FAX(916)387-9734 <br /> 1.2• Southern California: Traffic Control Service, Inc., 1818 E. Orangethorpe, Fullerton, CA 92831-5324, <br /> telephone(800)222-8274,FAX(714)526-9501 <br /> 4, <br /> 2. TrafFix Sand Barrels,manufactured by TrafFix Devices,Inc.,220 Calle Pintoresco,San <br /> Clemente,CA 92672,telephone(949)361-5663,FAX(949)361-9205 <br /> 2.1. Northern California: United Rentals, Inc., 1533 Berger Drive, San Jose, CA 95112 telephone <br /> (408)287-4303,FAX(408)287-1929 <br /> 2.2. Southern California: Statewide Safety & Sign, Inc., P.O. Box 1440, Pismo Beach, CA 93448 telephone <br /> (800)559-7080,FAX(805)929-5786 <br /> Modules contained in each temporary crash cushion shall be of the same <br /> type at each location. The color of the modules <br /> shall be the standard yellow color, as furnished by the vendor,with black lids. The modules shall exhibit good <br /> free from structural flaws and objectionable surface defects. The modules need not be new. Good used undamaged <br /> conforming to color and quality of the types specified herein may be utilized. If used Fitch modules requiringworkmanship <br /> furnished, the top edge of the seal shall be securely fastened to the wall of the module by a continuous strip modules <br /> tape. a seal are <br /> Modules shall be filled with sand in conformance with the manufacturer's directions, and to the sand heavy duty <br /> kilograms for each module shown on the plans. Sand for filling the modules shall be clean washed con <br /> commercial uali capacity in <br /> quality. At the time of placing in the modules, the sand shall contain not more than 7 percent water as <br /> determined by California Test 226. Crete sand of <br /> Modules damaged due to the Contractor's operations shall be repaired immediately by the Contractor at the Co <br /> expense. Modules damaged beyond repair, as determined by the Engineer, due to the Contractor's operations shall be <br /> removed and replaced by the Contractor at the Contractor's expense. Contractor's <br /> Contract No. 10-OM7104 <br /> 155 <br />