My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PW-ENCDRWY-2403198
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2024
>
Driveway Permits
>
PW-ENCDRWY-2403001 thru PW-ENCDRWY-2403500
>
PW-ENCDRWY-2403198
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 8:47:37 AM
Creation date
4/7/2025 8:45:30 AM
Metadata
Fields
Template:
Permits_Development_Driveway
DocName
PW-ENCDRWY-2403198
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2024
Location
N. Thornton Road near Capitol Ave.
Driveway Type
Commercial
Address
3500 Deer Creek Road, Palo Alto, CA 94304
Application
Tesla
Project #
PWP110005
Type
Driveway Encroachment
Text box
ID:
1
Creator:
Created:
4/7/2025 8:46 AM
Modified:
4/7/2025 8:46 AM
Text:
10/30/2024
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ANY OTHER <br />REGULATING AUTHORITIES WHICH HAVE AUTHORITY OVER ANY PORTION OF THE <br />WORK. <br />PRIOR TO COMMENCEMENT OF ANY WORK, THE CONTRACTOR SHALL VERIFY <br />EXISTING CONDITIONS AND NOTIFY THE DESIGN PROFESSIONAL IN RESPONSIBLE <br />CHARGE FROM TESLA OF ANY DISCREPANCIES. ANY WORK PERFORMED IN <br />CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE CORRECTED AT THE <br />SUBCONTRACTORS SOLE EXPENSE. <br />SUBCONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO TESLA <br />FOR APPROVAL BEFORE MAKING ANY CHANGES. DEVIATION FROM PLANS BEFORE <br />WRITTEN APPROVAL FROM TESLA PLACES LIABILITY ON THE SUBCONTRACTOR. <br />ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT <br />PROVIDED, CONTRACTOR SHALL USE STANDARD CONSTRUCTION PRACTICES. <br />ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND <br />EQUIPMENT TO MATCH EXISTING FINISHES. <br />ANY METAL SHAVINGS FROM SITE WORK SHALL BE CLEANED FROM ALL SURFACES <br />WHERE OXIDIZED OR CONDUCTIVE METAL SHAVINGS MY CAUSE RUST, ELECTRICAL <br />SHORT CIRCUITS, OR OTHER DAMAGE. <br />APPROVALS FROM BUILDING INSPECTORS SHALL NOT CONSTITUTE AUTHORITY TO <br />DEVIATE FROM THE DRAWINGS. <br />NEW PAVEMENT INSTALLED AS PART OF THIS PROJECT SHALL MATCH EXISTING <br />PAVEMENT SECTION. ASPHALT AND GAB DEPTHS SHALL BE MAINTAINED. <br />GENERAL NOTES SUPERCHARGER NOTES <br />1.NEUTRAL MUST BE INCLUDED FOR PROPER OPERATION OF TESLA <br />SUPERCHARGERS. <br />2.ALL CONDUIT FURNISHED AND INSTALLED BY CONTRACTOR. ALL <br />WIRING FURNISHED BY TESLA AND INSTALLED BY CONTRACTOR. <br />3.ALL BUSHINGS AND WIRING INTERNAL OF PROPOSED SERVICE <br />EQUIPMENT PROVIDED BY MANUFACTURER. ANY MODIFICATIONS <br />SHALL REQUIRE ENGINEERING APPROVAL PRIOR TO ANY CHANGES <br />BEING MADE. <br />4.ALL ALUMINUM(AI) CONDUCTORS TO RECEIVE ANTI-OXIDATION <br />COATING DURING INSTALLATION. ALL OTHER CONDUCTORS ARE <br />COPPER UNLESS OTHERWISE NOTED. <br />5.THE FOLLOWING CHARGING CABINETS AND THE CHARGING POSTS <br />USED ON THIS PROJECT COMPLY WITH THE FOLLOWING STANDARDS: <br />·IEC 61851-23: 2014 / EN 61851-23: 2014 <br />·UL 2202: 2009(R2012) <br />·CAN CSA C22.2 NO. 107.1-01(R2011) <br />6.THE AFOREMENTIONED STANDARDS IDENTIFY THE REQUIREMENTS <br />MET BY THE EQUIPMENT, INCLUDING BUT NOT LIMITED TO: <br />·PROTECTION AGAINST ELECTRIC SHOCK <br />·OVERLOAD AND SHORT CIRCUIT PROTECTION <br />·FAULT PROTECTION <br />·DEGREES OF PROTECTION AGAINST ACCESS TO HAZARDOUS <br />LIVE PARTS <br />·THE INTERNAL COMPONENTS OF THE SYSTEM ARE <br />PROPRIETARY. ANY QUESTIONS CONCERNING ACTUAL <br />INTERNAL PROTECTIVE DEVICES MUST BE COORDINATED <br />DIRECTLY WITH TESLA. <br />7.TESLA SUPERCHARGER SIGNAL WIRING RATED 1000V AND USED FOR <br />POWER LIMITED CLASS 1 CIRCUITS SHALL BE PERMITTED TO RUN IN <br />CONDUITS, CABLE TRAYS, WIRE WAYS, OR RACEWAYS ALONG WITH <br />ASSOCIATED DC CONDUCTORS AS ALLOWED PER ART. 725.48(B)(1) <br />AND 620.36. <br />8.SUPERCHARGER CABINET AC CONDUCTORS SIZED UNDER <br />ENGINEERING SUPERVISION USING THERMAL MODELING SOFTWARE. <br />SPECIFICATIONS ABOUT THE TRENCHING REQUIREMENTS ARE SHOWN <br />IN E-501 <br />9.FOR DC RUNS IN EXCESS OF 330 FEET, CONTACT TESLA. <br />10.UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC OR UL LISTED <br />HDPE. THE ABOVEGROUND PORTION OF AN <br />UNDERGROUND/ABOVEGROUND TRANSITION SHALL BE SCHEDULE 80 <br />PVC OR UL LISTED HDPE. <br />11.ABOVEGROUND CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT <br />PHYSICAL DAMAGE SHALL BE RMC. ABOVEGROUND CONDUITS NOT <br />EXPOSED TO VEHICULAR OR EQUIVALENT DAMAGE SHALL BE <br />PERMITTED TO BE EMT. <br />12.IF APPROVED BY TESLA CONSTRUCTION MANAGER, ALTERNATIVE <br />CONDUIT MATERIALS SUCH AS FLEXIBLE OR FIBERGLASS ARE <br />PERMISSIBLE IF INSTALLED PER MANUFACTURER INSTALLATION <br />GUIDELINES AND LOCAL CODES. <br />13.WIRE SPLICES ARE NOT PERMITTED TO EXTEND WIRE RUN LENGTH. <br />CONTRACTOR IS RESPONSIBLE FOR RERUNNING FULL LENGTH OF <br />WIRE IF RUN LENGTH IS MISCALCULATED. <br />14.SPECIAL INSPECTION IS REQUIRED FOR ALL POST-INSTALLED <br />CONCRETE ANCHORS. <br />15.PLANT GUARANTEE: CONTRACTOR SHALL GUARANTEE ALL PLANTS <br />FOR A PERIOD OF ONE (1) YEAR FROM DATE OF PROJECT <br />ACCEPTANCE BY THE OWNER. CONTRACTOR IS RESPONSIBLE FOR <br />PLANT MAINTENANCE FOR THE FIRST GROWING SEASON. <br />16.IF EXISTING GRASS IS DAMAGED/REMOVED DURING CONSTRUCTION, <br />CONTRACTOR SHALL APPLY SEED PER HYDROSEED METHOD. RATING <br />OF SEED SHALL BE PER DISTRIBUTOR BASED ON SPECIES TYPE. <br />17.CONTRACTOR SHALL MATCH EXISTING LANDSCAPE; USE GRASS, <br />RIVER ROCK, MULCH ETC. TO MATCH EXISTING LANDSCAPE AROUND <br />EQUIPMENT, UNLESS OTHERWISE NOTED. <br />18.CONTRACTOR TO INSTALL WEED BARRIER IN FRONT OF <br />SUPERCHARGER CABINETS AND SWITCHBOARD. BARRIER TO EXTEND <br />FULL WIDTH AND DEPTH OF NEC REQUIRED WORKING CLEARANCES. <br />GENERAL NOTES <br />1.ALL ELECTRICAL WORK SHALL COMPLY WITH THE CALIFORNIA ELECTRIC <br />CODE AS AMENDED BY APPLICABLE STATE AND LOCAL CODES. <br />2.ALL WIRING SHALL BE MANAGED IN A PROFESSIONAL, WORKMAN-LIKE <br />MANNER AND MUST BE SUPPORTED, SECURED, AND PROTECTED TO <br />PREVENT DAMAGE. <br />3.AC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER <br />ART 210.5 OR 215.12. UNLESS OTHERWISE REQUIRED BY ART 210.5(1) OR AHJ, <br />COLOR-CODING OF POWER CONDUCTORS SHALL BE AS FOLLOWS: <br />CONDUCTOR 277/480V 120/208V <br />PHASE A BROWN BLACK <br />PHASE B ORANGE RED <br />PHASE C YELLOW BLUE <br />NEUTRAL GRAY WHITE <br />4.DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED PER ART 210.5 OR 215.12: <br />CONDUCTOR STD COLOR ALT COLOR <br />DC+RED RED-STRIPED <br />DC-BLACK BLACK-STRIPED <br />5.TERMINATIONS OF AC, DC, AND COMMUNICATIONS CONDUCTORS SHALL BE <br />PROFESSIONALLY AND LEGIBLY LABELED WITH CIRCUIT SCHEDULE <br />IDENTIFIER, CONDUCTOR SIZE (AS APPLICABLE) AND TERMINATION TORQUE. <br />6.ALL EQUIPMENT SHALL BE LISTED BY A NRTL IN COMPLIANCE WITH ART 110.3. <br />WHERE EXISTING NRTL LISTING CANNOT BE MAINTAINED, ENGINEERING <br />APPROVAL SHALL BE OBTAINED PRIOR TO EQUIPMENT MODIFICATION, AND <br />THE EQUIPMENT SHALL BE RELISTED BY A SUITABLE NRTL. <br />7.UNDERGROUND CONDUCTORS & CABLES TO BE INSTALLED IN CONDUIT UON. <br />8.ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO <br />BOXES AS REQUIRED BY NRTL LISTING. <br />9.REFER TO MANUFACTURER'S CURRENT PLANNING AND INSTALLATION <br />MANUAL FOR TORQUE SPECS FOR ALL BOLTS AND TERMINAL CONNECTIONS. <br />10.ALL CONDUCTOR TERMINATIONS ON BUSSING OR TRANSFORMER SPADES <br />SHALL BE MADE WITH HIGH-PRESS CRIMP LUGS UON. <br />11.ALL TERMINATIONS OF ALUMINUM CONDUCTORS SHALL BE PROPERLY <br />INSTALLED WITH BEST PRACTICES INCLUDING BUT NOT LIMITED TO: <br />·USE OF TERMINATION EQUIPMENT RATED FOR ALUMINUM AT THE <br />CONDUCTOR TEMPERATURE, CURRENT, AND VOLTAGE <br />·ALLOWANCE FOR MOVEMENT DUE TO THERMAL <br />EXPANSION/CONTRACTION <br />·PROPER COATING OF EXPOSED ALUMINUM WITH ANTI-OXIDIZATION <br />COMPOUND <br />·USE OF CALIBRATED DEVICES TO TORQUE AND MARK TERMINALS TO <br />REQUIRED SETTINGS <br />12.DUCT SEAL COMPOUND SHALL BE APPLIED WHEREVER CONDUITS <br />TRANSITION INDOOR/OUTDOOR OR UNDERGROUND/ABOVEGROUND. REFER <br />TO EQUIPMENT NOTES FOR ADDITIONAL DUCT SEAL REQUIREMENTS. <br />13.BELL ENDS SHALL BE INSTALLED WHEREVER CONDUIT ENTERS EQUIPMENT <br />FROM UNDERGROUND AND WHEREVER POTENTIAL FOR DAMAGE TO <br />CONDUCTORS IS PRESENT AT ANY POINT. BELL ENDS SHALL NOT PREVENT <br />THE USE OF GROUNDING FITTINGS OR COUPLERS WHEN REQUIRED. <br />14.ALL STUB-UPS WITHIN FLOOR-MOUNTED EQUIPMENT SHALL BE 3-5" ABOVE <br />FINISHED GRADE. <br />15.ALL CONDUITS EXPOSED TO VEHICULAR OR EQUIVALENT PHYSICAL DAMAGE <br />SHALL BE RIGID GALVANIZED STEEL. <br />16.GROUND LUGS SHALL BE RATED FOR THEIR ENVIRONMENT AND CONDITION <br />OF USE. <br />ELECTRICAL NOTES <br />SITE LEGEND <br />(EXISTING OBJECTS) <br />SCOPE OF WORK <br />UTILITY PG&E - RULE 29 <br />CATEGORY ITEMS TESLA TESLA <br />CONTRACTOR UTILITY <br />PRIMARY <br />PRIMARY TRENCHING X <br />INSTALL PRIMARY CONDUIT X <br />INSTALL PULL ROPE X <br />INSTALL PRIMARY FEEDERS X <br />PROVIDE ROAD CUTS / ROAD BORES X <br />PAVEMENT REPLACEMENT X <br />TRANSFORMER <br />PROVIDE TRANSFORMER PAD X <br />INSTALL TRANSFORMER PAD X <br />PROVIDE TRANSFORMER X <br />INSTALL TRANSFORMER X <br />INSTALL CONNECTIONS - PRIMARY X <br />INSTALL CONNECTIONS - SECONDARY X <br />PROVIDE BOLLARDS X <br />INSTALL BOLLARDS X <br />SWITCHBOARD <br />PROVIDE METER X <br />INSTALL METER X <br />LAND SECONDARY FEEDERS X <br />PROVIDE SWITCHBOARD PAD & PRE-CAST X <br />INSTALL SWITCHBOARD PAD & PRE-CAST X <br />SECONDARY <br />SECONDARY TRENCHING X <br />PROVIDE CONDUIT FROM SWITCHBOARD OUT <br />5' TO TRANSFORMER X <br />INSTALL CONDUIT FROM SWITCHBOARD OUT 5' <br />TO TRANSFORMER X <br />INSTALL PULL ROPE X <br />TERMINATE SECONDARY CONDUCTORS AT <br />SWITCHBOARD X <br />TERMINATE SECONDARY CONDUCTORS AT <br />TRANSFORMER X <br />PROVIDE SECONDARY CONDUCTORS X <br />INSTALL SECONDARY CONDUCTORS X <br />PROVIDE ROAD CUTS / ROAD BORES X <br />PAVEMENT REPLACEMENT X <br />1.CAT5E/6 SHIELDED CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY <br />CHAINS OF INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM <br />TOTAL DISTANCE OF 328 FEET (100M) PER CHAIN. <br />2.RS485 CABLE RUNS, WHICH INCLUDE INDIVIDUAL DAISY CHAINS OF <br />INVERTERS FOR DIRECT MONITORING, HAVE A MAXIMUM TOTAL <br />DISTANCE OF 3280 FEET (1000M) PER CHAIN. <br />3.SWITCHES, METERS, POWERPACK CONTROLLERS, CT'S, AND PT'S, <br />AND CONDUCTORS MARKED "PRE-INSTALLED" IN THE LINE DIAGRAM <br />WILL ARRIVE TO SITE PRE-INSTALLED WITHIN THE SWITCHBOARD, <br />AND WILL NOT REQUIRE ANY FIELD INSTALLATION OR MODIFICATION <br />OF ANY KIND. <br />COMMUNICATION NOTES <br />1.LOAD SIDE INTERCONNECTIONS SHALL COMPLY WITH CEC 705.12(B). <br />2.WHERE THE INTERCONNECTION POINT OCCURS ON FEEDERS, THE FEEDER <br />AMPACITY SHALL NOT BE LESS THAN THE SUM OF ALL THE SOURCES <br />CONNECTED TO THE FEEDER UNLESS THE FEEDER IS PROTECTED ON THE <br />LOAD SIDE OF THE INTERCONNECTION POINT WITH OVERCURRENT <br />PROTECTION NO GREATER THAN THE AMPACITY OF THE FEEDER. <br />3.TAP CONNECTIONS SHALL COMPLY WITH ART 240.21(B). <br />4.WHERE THE SUM OF ALL THE OVERCURRENT DEVICE RATINGS ON THE <br />PANEL LOAD SIDE OF A MAIN OVERCURRENT PROTECTION DEVICE ARE LESS <br />THAN THE RATING OF THE PANEL, PERMANENT WARNING LABELS WITH THE <br />FOLLOWING WORDING MUST BE APPLIED: <br />WARNING: <br />THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. <br />5.WHERE THE SUM OF THE UTILITY OVERCURRENT DEVICE AND 125% OF <br />INVERTER OUTPUT CIRCUIT CURRENT DOES NOT EXCEED 120% OF THE <br />RATING OF THE BUSBAR, THE INTERCONNECTION POINT MUST BE ON THE <br />OPPOSITE END OF THE BUSBAR FROM THE INCOMING UTILITY SOURCE AND <br />A PERMANENT WARNING LABEL MUST BE APPLIED TO THE <br />INTERCONNECTION POINT. <br />6.LOAD SIDE INTERCONNECTIONS SHALL BE MADE IN ACCORDANCE WITH THE <br />EQUIPMENT MANUFACTURER'S INSTRUCTIONS AND SHALL NOT INVALIDATE <br />THE NRTL LISTING OF THE EQUIPMENT. WHERE EXISTING NRTL LISTING <br />CANNOT BE MAINTAINED, EQUIPMENT MUST BE RELISTED BY AN APPROVED <br />NRTL SUITABLE FOR THE EQUIPMENT. <br />UTILITY-INTERACTIVE INVERTER <br />LOAD-SIDE INTERCONNECTION NOTES <br />(FOR FUTURE PV SYSTEM AND BESS) <br />SS <br />RECTANGULAR STORM <br />WATER INLET <br />LIGHT POLE <br />UTILITY POLE <br />SIGN <br />SANITARY SEWER MANHOLE <br />WV <br />WATER VALVE <br />TREE <br />ELE UNDERGROUND <br />ELECTRIC LINE <br />FENCE <br />SS UNDERGROUND <br />SANITARY SEWER LINE <br />OHW OVERHEAD ELECTRIC <br />LINE <br />1"12"0 <br />PROPRIETARY AND CONFIDENTIAL <br />ABCDEFGH <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />DATENO.REVISIONORIGINAL SIZE 24"X36" <br />SHEET SIZE ARCH "D" <br />3500 DEER CREEK RD. <br />PALO ALTO, CA 94304 <br />(650) 681-5000 <br />3/27/2024AARCH SITE PLAN COMMENTS10/18/2024BCIVIL AND BUILDING COMMENTS14700 THORNTON RDLODI, CA 95242, USNOTES <br />G-002 <br />REV: B IFP <br />MVANDERWALPLOT DATE: 10/25/2024 9:20 a. m. <br />JB-9528024TESLA SUPERCHARGER_LODI, CAPHASE 1: 16 SUPERCHARGERS
The URL can be used to link to this page
Your browser does not support the video tag.