Laserfiche WebLink
Printed on:Tuesday 02/25/2025 03:21 PM 29C0227/AAAT/148024Pageof7 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />9 <br />DESCRIPTION UNDER STRUCTURE <br />CHANNEL DESCRIPTION <br />Sinuous creek with moderately vegetated slopes (grass and weeds). The bed is comprised of silt and gravel. <br />Photo 5 <br />Decay in the bottom of Girder 17 at Bent 3. Span 2 side shown <br />Photo 6 <br />Check in Girder 5 in Span 1 near Bent 2 <br /> SUPERSTRUCTURE PHOTOGRAPHS <br />TYPE OF SERVICE UNDER <br />N NOT APPLICABLE (NBI)UNDERCLEARANCES V - H <br />8 EQUAL DESIRABLEWATER ADEQUACY <br /> MVERT-LIFT BRIDGE NAV MIN VERTICAL CLEAR <br />NAVIGATION CONTROL <br />0.0 MNAVIGATION HORIZONTAL CLEARANCE <br />0.0 MNAVIGATION VERTICAL CLEARANCE <br />PIER PROTECTION <br />0: NO CONTROL5-WATERWAY <br />3 SC - UNSTABLESCOUR <br />07/14/2021SCOUR POA DATE <br />CHANNEL PROTECTION 6 BANK SLUMPING <br />N/A <br />(42b) <br />(69) <br />(71) <br />(61) <br />(113) <br />(38) <br />(111) <br />(39) <br />(116) <br />(40) <br />SUPERSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br />206 Column-Timber <br />Decay/Section Loss (Timber) <br />2 <br />2 <br />6 <br />4 <br />each <br />each <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 6 <br /> 4 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 01140 <br />SUPERSTRUCTURE <br />SUBSTRUCTURE <br />SUPERSTRUCTURE RATING =(59) (6) <br />SUBSTRUCTURE RATING =(60)(4) <br />(111-1150) Check/Shake (Timber) <br />(111-1170) Split/Delamination (Timber) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />In Girders 4, 5, 7, 9, 10 and 16, there is an intermittent full length check up to 0.5 inches deep in the bottom of the girders. (See <br />Photo 4 dated 11/20/2019). This condition has been previously reported and no significant changes were noted. <br />In Girder 6, there is an intermittent full length check up to 0.5 inches deep at mid-height of the girder. See Photo 8 dated 11/10/2023. <br />This condition has been previously reported and no significant changes were noted. <br />Span 3: <br />In Girder 2, there is a full length check up to 0.5 inches deep on the right side of the girder. (See Photo 8 dated 11/29/2021). This <br />condition has been previously reported and no significant changes were noted. <br />There is a split in the end of Girder 18 at Bent 2 on the Span 1 side. The split is up to 0.125 inches wide x 12 inches long. In addition, <br />there is a section of missing wood up to 0.5 inches wide x 4 inches long. (See Photo 7 dated 11/29/2021). This condition has been <br />previously reported in Girder 18 at Bent 2 in both Spans 1 and 2. Girder 18 has been replaced in Span 2. See Photo 1.