Laserfiche WebLink
Printed on:Friday 12/13/2024 02:52 PM 29C0314/AAAW/147520Pageof6 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />Photo 1 <br />Erosion behind the timber lagging and hole in the AC on the left <br />side of Abutment 5 <br />Photo 2 <br />Missing section of timber lagging wingwall on the left side of <br />Abutment 1 <br />Photo 3 <br />Broken section of timber lagging at the wingwall on the left side <br />of Abutment 5 <br />Photo 4 <br />Backfilled erosion hole behind the timber lagging on the right <br />side of Abutment 5 <br />SUBSTRUCTURE PHOTOGRAPHS <br />228 <br />235 <br />256 <br />Pile-Timber <br />Pier Cap-Timber <br />Slope Protection <br />2 <br />2 <br />2 <br />1 <br />30 <br />2 <br />ea. <br />m <br />ea. <br /> 1 <br /> 30 <br /> 2 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE <br />SUBSTRUCTURE RATING =(60)6 <br />(216-1140) Decay/Section Loss (Timber) <br />(228) Pile-Timber <br />(235) Pier Cap-Timber <br />(256) Slope Protection <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />will continue to be monitored. (See Photos 2, 4 through 6). This condition has been previously reported and no significant changes <br />were noted. <br />The pile element is included to indicate the presence of piles on this structure. The piles were not exposed for visual inspection. No <br />indication of pile distress was noted in any substructure element. <br />There were no significant defects noted. <br />There were no significant defects noted.