My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
29C0022_AABI_2025-MAY
PublicWorks
>
ArcGIS Online
>
Bridges
>
29C-022
>
29C0022_AABI_2025-MAY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 1:23:40 PM
Creation date
7/2/2025 1:21:43 PM
Metadata
Fields
Template:
Supporting Docs - Bridge
Bridge #
29C-022
Type - Bridge Supporting Doc
Inspection
Name
Grant Line Canal - Tracy Boulevard
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Department of Transportation - Division of Maintenance <br />Structure Maintenance & Investigations <br />MECHANICAL/ELECTRICAL ELEMENT INSPECTION RATINGS AND NOTES <br />Elem Defect/ Element Description <br />No. Prot Defect <br />Env Total Units Qty in each Condition State <br />Qty CS 1 CS 2 CS 3 CS 4 <br />607 Control System - Electrical 2 1 ea. 0 1 0 0 <br />9008 Functional Obsolescence 2 1 ea. 0 1 0 0 <br />(607) Control System - Electrical <br />Non -Routine Inspection Element Notes: <br />Bridge control systems are located in the bridge house. The control system consists of a traffic control desk and a moveable span <br />control desk. A separate electrical cabinet houses the electrical components that supply power and provide control for the electric <br />motors. <br />(607-9008) Functional Obsolescence <br />Non -Routine Inspection Element Notes: <br />Mech/Elect (06/01/2021) Some components of the control desks are old and may soon be phased out by the manufacturer. The <br />components still function properly. <br />Some labels on the control desk and the electrical cabinet are fading but are still legible. <br />One of the power (kW) measuring meters on the span control desk does not work. <br />(5/8/2023) Condition still present. <br />(5/12/25) Condition still present. <br />608 Interlocking System - Mechanical 2 2 ea. 2 0 0 0 <br />(608) Interlocking System - Mechanical <br />Non -Routine Inspection Element Notes: <br />The bridge mechanical control system consists of lever actuated fully seated limit switches and two sets of bronze cams connected to <br />the drive machinery. One set gives bridge span position indications the other is connected to the heel lock system and gives the <br />indication for the hold down bar positions. <br />609 Interlocking System - Electrical 2 2 ea. 2 0 0 0 <br />(609) Interlocking System - Electrical <br />Non -Routine Inspection Element Notes: <br />The interlocking system consists of limit switches that regulate the sequence of the traffic equipment and movable span operation. <br />610 Pier Protection - Structural 2 1 ea. 1 0 0 0 <br />(610) Pier Protection - Structural <br />Non -Routine Inspection Element Notes: <br />Pier protection consists of timber fenders with diagonal skip sheathing of Span 11, protecting Piers 11 & 12. Clearance gauges are <br />mounted on the upstream and downstream ends of the fender at Pier 11. <br />The timber fenders appeared in fair condition. One diagonal sheathing plank is missing at the center of the fender along Pier 11. <br />612 Power System - Electrical 2 1 ea. 0 0 0 1 <br />9005 Accessibility and Labeling 2 1 ea. 0 0 0 1 <br />(612) Power System - Electrical <br />Non -Routine Inspection Element Notes: <br />Utility power is supplied to the bridge house from the north side. Power is provided to the south bascule leaf by means of a <br />submarine cable. Backup power is provided by a generator located off -site. The power supply is 240 Volts AC. <br />(612-9005) Accessibility and Labeling <br />Non -Routine Inspection Element Notes: <br />Mech/Elect (06/01/2021) There are no arc flash labels on the cabinet. The cabinet is very dusty. <br />Four cabinet sections of the MCC donut have door handles/locks to close the cabinet doors. <br />Some components of the power system are old and may soon be phased out by the manufacturer. The components still function <br />normally. <br />(5/8/2023) Condition still present. <br />(5/12/2025) Condition still present. <br />The North kW meter on the bridge control console is not working. <br />The electrical service cabinet is rusty and is a fire hazard. <br />There is no dielectric mat in front of the motor control. <br />613 Traffic Control Sys - Mechanical 2 3 ea. 3 0 0 0 <br />(613) Traffic Control Sys - Mechanical <br />Non -Routine Inspection Element Notes: <br />Double traffic gates are located at near end of the bridge, an advance gate and a traffic gate closer to the center of the span. Each <br />Printed on: Monday 06/23/2025 03:38 PM Page 8 of 12 29C0022/AABI/153157 <br />
The URL can be used to link to this page
Your browser does not support the video tag.