My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
29C0028_AAAU_2025-APR
PublicWorks
>
ArcGIS Online
>
Bridges
>
29C-028
>
29C0028_AAAU_2025-APR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 1:26:11 PM
Creation date
7/2/2025 1:24:39 PM
Metadata
Fields
Template:
Supporting Docs - Bridge
Bridge #
29C-028
Type - Bridge Supporting Doc
Inspection
Name
Old River - South Tracy Boulevard
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />DECK ELEMENT INSPECTION RATINGS AND NOTES (58) DECK RATING = 4 <br />Elem Defect/ Element Description Env Total Units Qty in each Condition State <br />No. Prot Defect Qty CS 1 CS 2 CS 3 CS 4 <br />(16-1130) Cracking (RC and Other) <br />throughout the deck. There is pattern cracking developing up to 0.05 inches wide spaced as close as 3 inches on center in Span 1. <br />(See Photos 5 and 6). This condition has been previously reported, crack width and pattern cracking in Span 1 changes were noted. <br />There are transverse cracks up to 0.01 inches wide x full bay width spaced 3 feet on center with light efflorescence throughout the <br />soffit. Span 3 soffit is most severe. (See Photo 5 dated 09/21/2022). This condition has been previously reported and no significant <br />changes were noted. <br />Non -Routine Inspection Element Notes: <br />Notes from the 11/16/2015 Underwater Investigation: "As reported in the 11/2/2010 UWI report, there were approximately 40 full widtl• <br />soffit cracks found, mostly in Span 3. There was no indication of rust or other distress in the deck. This condition is accounted for in <br />the 9/24/2014 routine inspection report ELI table with the cracking defect applied in condition state 2. The 11/16/15 UW inspection <br />found no significant changes to those conditions." <br />(16-16-1190) Abrasion (PS Conc./RC) <br />The deck is abraded throughout and is missing coarse aggregate. (See Photos 3, 6 and archived Photo 4 dated 09/15/2020). This <br />condition has been previously reported and no significant changes were noted. <br />(16-512) Deck Wearing Surface -Epoxy <br />This quantity accounts for the thin epoxy overlay in the northbound lane over a length of approximately 180 feet near Abutment 8. <br />(16-512-3212) Delam./Spall/Patch-Epoxy(WS) <br />The epoxy overlay is delaminating, exposing the concrete deck in the traveled way. There are areas of the overlay up to 5 feet long x <br />24 inches wide that are now bare. This condition accounts for approximately 10% of the overlay by area. (See Photo 7). This <br />condition has been previously reported and no significant changes were noted. <br />RAIL INFORMATION <br />(36a) Rail Code 0 (36b) Transition 0 (36c) Appr Guardrail 0 (36d) Appr Guardrail End 0 Roadway Speed 55 MPH <br />JOINT/APPROACH/RAIL ELEMENT INSPECTION RATINGS AND NOTES <br />Elem Defect/ Element Description Env Total Units Qty in each Condition State <br />No. Prot Defect Qty CS 1 CS 2 CS 3 CS 4 <br />302 Joint -Compression Seal 2 19 m 14 4 0 1 <br />2320 Seal Adhesion (Joints) 2 1 0 0 0 1 <br />2360 Adjacent Deck or Header (Joints) 2 4 0 4 0 0 <br />(302) Joint -Compression Seal <br />New Type B joint seals were placed prior to the 2018 routine inspection. See Photo 4 dated 09/19/2018. <br />(302-2320) Seal Adhesion (Joints) <br />There is a section up to 2.5 feet long of missing joint seal in the northbound lane at Abutment 1. (See Photo 6 dated <br />09/21/2022). This condition has been previously reported and no significant changes were noted. <br />(302-2360) Adjacent Deck or Header (Joints) <br />The joint headers at both abutments have small spalls up to 2 inches in diameter and longitudinal cracks throughout. (See <br />Photo 5 dated 09/15/2020). This condition has been previously reported and no significant changes were noted. <br />330 Railing -Metal 2 201 m 201 0 0 0 <br />(330) Railing -Metal <br />There were no significant defects noted. <br />SUPERSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES (59) SUPERSTRUCTURE RATING = (7) <br />Elem Defect/ Element Description Env Total Units Qty in each Condition State <br />No. Prot Defect Qty CS 1 CS 2 CS 3 CS 4 <br />110 Girder/Beam-RC 2 403 m 403 0 0 0 <br />(110) Girder/Beam-RC <br />Routine Inspection Element Notes: <br />Printed on: Tuesday 06/10/2025 10:32 AM Page 5 of 9 29C0028/AAAU/151624 <br />
The URL can be used to link to this page
Your browser does not support the video tag.