Laserfiche WebLink
Department of Transportation - Division of Maintenance <br />Structure Maintenance & Investigations <br />SUPERSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br />Elem Defect/ Element Description <br />No. Prot Defect <br />Env Total <br />Qty <br />(59) SUPERSTRUCTURE RATING = 6 Eq <br />Units Qty in each Condition State <br />CS 1 CS 2 CS 3 CS 4 <br />(152-1000) Corrosion <br />4 and 5 dated 11/04/2020). This condition has been previously reported and no significant changes were noted. <br />(152-515-3450) Paint Sys Breakdown (Steel PC) <br />There are large areas of rust and freckled rust throughout the girders. The top flange of the floor beams are the most severe. <br />Approximately 50% of the paint area no longer offers protection to the underlying steel. (See Photos 4 and 5 dated 11/05/2020). This <br />condition has been previously reported and no significant changes were noted. <br />311 Bearing -Moveable 2 2 each 2 0 0 0 <br />(311) Bearing -Moveable <br />There were no significant defects noted. <br />313 Bearing -Fixed 2 2 each 2 0 0 0 <br />(313) Bearing -Fixed <br />There were no significant defects noted. <br />SUâ–º'ERSTRUCTURE PHOTOGRAPHS <br />Photo 1 <br />Side View (looking north) <br />DESCRIPTION UNDER STRUCTURE <br />Photo 2 <br />Underside view <br />(42b) TYPE OF SERVICE UNDER <br />5-WATERWAY <br />(38) NAVIGATION CONTROL 0: NO CONTROL <br />(69) UNDERCLEARANCES V - H <br />N NOT APPLICABLE (NBI) <br />(111) PIER PROTECTION <br />N/A <br />(71) WATER ADEQUACY <br />8 EQUAL DESIRABLE <br />(39) NAVIGATION VERTICAL CLEARANCE <br />0.0 M <br />(61) CHANNEL PROTECTION <br />4 PROTECTION UNDERMINED <br />(116) VERT-LIFT BRIDGE NAV MIN VERTICAL CLEAR <br />M <br />(113) SCOUR <br />U UNKNOWN FOUNDATION <br />(40) NAVIGATION HORIZONTAL CLEARANCE <br />0.0 M <br />SCOUR POA DATE <br />08/13/2010 <br />CHANNEL DESCRIPTION <br />Dirt and gravel. <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES (60) SUBSTRUCTURE RATING = 7 <br />Elem Defect/ Element Description Env Total Units Qty in each Condition State <br />No. Prot Defect Qty CS 1 CS 2 CS 3 CS 4 <br />205 Column -RC 2 6 each 6 0 0 0 <br />(205) Column -RC <br />There were no significant defects noted. <br />Printed on: Tuesday 06/10/2025 03:14 PM Page 7 of 9 29C0038/AAAZ/152573 <br />