My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 of 8 <br /> 4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ff] Industry Standard ❑ Professional Engineer <br /> Other(Specify) <br /> Test Method Used: ❑ Pressure El Vacuum ❑ Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Vacuum Gauge Equipment Resolution: 0-30 Hg <br /> Tank # 1 Tank # Tank # Tank # <br /> Is Tank Exempt From Testing?' ❑ Yes 0 No ❑ Yes ❑ No L3 Yes ❑ No L3 Yes Ll No <br /> Tank Capacity: 20,000 gallons <br /> Tank Material: Steel <br /> Tank Manufacturer: Unknown <br /> Product Stored: Reg/Prem <br /> Wait time between applying <br /> pressurelvacuumlwaterand starting 5 minutes <br /> test: <br /> Test Start Time: 12:00 PM <br /> Initial Reading(Ri): -10 Hg <br /> Test End Time: 1:00 PM <br /> Final Reading(RF): -10 Hg <br /> Test Duration: 1 hour <br /> Change in Reading(RF-Ri): 0 <br /> Pass/Fail Threshold or Criteria: 0 <br /> Test Result: T1 Pass ❑ Fail ❑ Pass ❑ Fail Q Pass ❑ Fail Q Pass ❑ Fail <br /> Was sensor removed for testing? ©Yes Q No [INA ❑Yes Q No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> Was sensor properly replaced after 0 Yes ❑ No ❑ NA O Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA Q Yes ❑ No ❑ NA <br /> testing? <br /> Comments— include information on repairs made prior to testing,and recommended follow-up for failed tests <br /> ' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, <br /> such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment testing. <br /> (California Code of Regulations,Title 23, Section 2637(x)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.