Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 4 of 8 <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer 0 Industry Standard ❑Professional Engineer <br /> ❑ Other(Specify) <br /> Test Method Used: ❑ Pressure ❑Vacuum IF)Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: Caldwell Equipment Resolution: <br /> Sump 1 Sump 2 Sump 3 Sump 4 <br /> Sump Diameter: <br /> 46" 46" 46" 46„ <br /> 9„ <br /> 62" 45" 5 <br /> Sump Depth: 57" <br /> Sump Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Height from Tank Top to Top of 15" 15" 14" 17" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 10" 10,E $" 20" <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Dry Dry Dry Dry <br /> Portion of Sump Tested' 2"Above Product 2"Above Product 2"Above Product 2"Above Product <br /> Does turbine shut down when sump <br /> sensor detects liquid(both product and ❑ Yes ❑ No © NA L3 Yes ❑ No NA ® Yes ❑ No NA ❑ Yes ❑ dIMNA <br /> water T <br /> Turbine shutdown response time -------SEE COMMENT BEL -------- <br /> Is system programmed for fail-safe ❑ Yes ❑ No 0 NA ❑Yes ❑ No 0 NA ❑ Yes ❑ No 0 NA ❑ Yes ❑shutdown?'Was fail-safe verified to be ❑ Yes ❑ No 0 NA ❑ Yes ❑ No 0 NA ❑Yes ❑ No 0 NA ❑ Yes ❑o erationalT <br /> Wait kime between applyingpressurefvacuumiwater and starting 5 minutes 5 minutes5 minotes 5 mintest:Test Start Time: 10:50 AM 10:50 AM 1:25 PM 4:00 <br /> Initial Reading(Ri): 0.0025 0.0025 ------ ___-- <br /> Test End Time: 11:20 AM 11:20 AM ------ ALOINo <br /> Final Reading(RF): 0.0025 0.002 <br /> ------ ------ <br /> Test Duration: 30 minutes 30 minutes ------Change in Reading(RF-Ri): 0 0 -PasslFail Threshold or Criteria: 1/16"hr. 1/16" hr. <br /> T45t ReSuft: D Pass ❑ Fail L7 Pass ❑ Fail p Pass ® Fail Was sensor removed for testing? I� Yes ❑ No ❑ NA 0 Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA Was sensor properly replaced after 0 Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> testing? <br /> Comments- include information on repairs made prior to testing,and recommended follow-up for failed fesfs <br /> Turbine Shut Down done during Annual Monitor Certification. <br /> Sump 3 has two bad Secondary boots inside 6 over 4 Amerion test boots. <br /> Sump 4 failed, don't know why. <br /> ' if the entire depth of the sump is not tested,specify how much was tested. if the answer to ay of the questions indicated with an <br /> asterisk(*)is"NO" or"NA",the entire sump must be tested. (See S"CB LG-160) <br />