My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
23500
>
2800 - Aboveground Petroleum Storage Program
>
PR0528391
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/5/2019 3:22:29 PM
Creation date
8/24/2018 6:36:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528391
PE
2832
FACILITY_ID
FA0007158
FACILITY_NAME
CDCR-DEUEL VOCATIONAL INSTITUTION
STREET_NUMBER
23500
STREET_NAME
KASSON
STREET_TYPE
Rd
City
Tracy
Zip
95304
APN
23912001
CURRENT_STATUS
01
SITE_LOCATION
23500 Kasson Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
EJimenez
Supplemental fields
FilePath
\MIGRATIONS\K\KASSON\23500\PR0528391\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
10/24/2017 3:58:18 PM
QuestysRecordID
3695872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 ( <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CDCR-DEUEL VOCATIONAL INSTITUTION 23500 KASSON RD, TRACY May 24, 2016 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 716 CFR 112.8(c)(8)(i-iv) Failed to provide each container with a high level monitoring device. <br /> According to the reviewed SPCC, no automatic or direct visual volume gauge are present on the following tanks: <br /> 1) 400-gallon diesel tank at Fresh Water Booster Station <br /> 2) Two 180-galon diesel tanks at the flood control ditch pumps. <br /> At least one of the following devices must be installed in each container: <br /> - High liquid level alarm with audible or visual signal <br /> - High liquid level pump cutoff device set to stop flow at a predetermined content level <br /> - Direct audible or code signal communication between the container gauger and the pumping station <br /> - Fast response system, such as digital computer, telepulse, or direct vision gauge. If a direct vision gauge is <br /> being used for determining the liquid level of each tank, a person must be present to monitor gauges and the overall <br /> filling of the tanks. <br /> Immediately install an approved liquid level sensing device in accordance with CFR 112.8 and implement necessary <br /> procedures to ensure that the devices are fully functional and in use at all times during tank filling operations, or <br /> provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 717 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation. <br /> Existing liquid level sensing devices appeared to have not been tested (no documentation was available for review that <br /> illustrates that they have been tested.) Procedures and frequency of testing for these devices were not addressed in <br /> the Spill Prevention, Control, and Countermeasure (SPCC) plan. Liquid level sensing devices must be installed in <br /> accordance with CFR 112.8 and shall be regularly tested to ensure proper operation. Immediately conduct all <br /> necessary testing of liquid level sensing devices, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> 720 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers. <br /> A single wall 180-gallon tank was located at the maintenance shop, Svetlana AN along with the maintenance shop <br /> workers indicated that it's a portable tank. No secondary containment was provided for this tank. Portable oil storage <br /> containers must be positioned or located to prevent a discharge and shall be furnished with a secondary means of <br /> containment sufficient to contain the capacity of the largest single container with sufficient freeboard to contain <br /> precipitation. Immediately provide sufficient secondary containment for this and all other portable containers at this <br /> facility, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Page 6 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.