Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> CONTINUATION FORM Page: 5 of 7 <br /> OFFICIAL INSPECTION REPORT Date: 10/21/13 <br /> Facility Address: Tracy Air Center (TAC) 5749 South Tracy Blvd, Tracy Program: APSA <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> 501. Failed to include cross-referencing section for Plan that does not follow sequence specified in this <br /> section. Operator's Plan does not follow sequence nor provide cross-referencing. Owner/ operator must <br /> prepare Plan in accordance with good engineering practices with full approval from management at a <br /> level of authority to commit necessary resources to fully implement Plan. If the Plan does not follow the <br /> sequence specified in this section, owner/operator must prepare an equivalent Plan acceptable to <br /> Regional Administrator that meets all of the applicable requirements listed & with supplements with a <br /> section cross-referencing location of requirements listed & equivalent requirements in other prevention <br /> plan. Correct by providing cross-referencing section for Plan or follow sequence of Plan. <br /> 502. Plan lacks full approval of management. The AST are owned by City of Tracy but operated by <br /> Tracy Air Center, it is likely that management approval must be made with the tank owners. The plan <br /> must have the full approval of management at a level of authority to commit the necessary resources to <br /> fully implement the plan. Immediately obtain required management approval for the SPCC Plan for this <br /> facility. <br /> 504. No facility diagram of the AST, underground fuel piping and dispensers were provided with the <br /> Plan. The plan shall include a facility diagram which must mark the location and contents of each fixed <br /> storage container and the storage area where mobile or portable containers are located. It must identify <br /> the location of and mark as "exempt" underground tanks. It must also include all transfer stations and <br /> connecting pipes, including intra-facility gathering lines. Immediately update the facility diagram to <br /> include all of the required information. Submit a legible copy of the updated facility diagram to the EHD. <br /> 506. Failed to include procedures for routine handling of products and discharge prevention methods. <br /> Section 2.5 discusses monitoring of fueling/transferring for the AST but lacks discussion of discharge <br /> prevention during the fueling an aircraft at the dispenser island. Discharge prevention methods includes <br /> procedures for routine handling of products at anytime with methods. Submit Plan including discharge <br /> prevention method for during fueling of an aircraft. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> Thuy Tran (209) 468-8257 <br /> EHD 23-02-003 Rev 04/19/12 CONTINUATION FORM <br />